volume evaporation
Recently Published Documents


TOTAL DOCUMENTS

2
(FIVE YEARS 1)

H-INDEX

1
(FIVE YEARS 0)

Processes ◽  
2020 ◽  
Vol 8 (4) ◽  
pp. 396
Author(s):  
Shuang Liang ◽  
Xiaoping Liang ◽  
Qian Tang

This paper presents the results of an experimental study on the extraction of KCl and the improvement of the zinc grade of secondary dust obtained from rotary-hearth-furnace secondary dust (RHF secondary dust) using alkali leaching (Na2CO3 solution) and evaporation–crystallization processes. The effects of the liquid–solid ratio and Na2CO3 content on the element leaching ratio in the alkali leaching process, as well as the effects of the volume–evaporation ratio and cooling temperature on KCl extraction in the evaporation–crystallization process, were investigated. The results showed that the optimum liquid–solid ratio was 6:1, and the optimum quantity of Na2CO3 was 1.5 times the basic quantity. The recovery ratio of zinc reached 95.23%, and the leaching ratio of K reached 79.01%. The experimental results of the evaporation–crystallization process demonstrated that the evaporation temperature was 80 °C, the volume evaporation ratio was 50%, the cooling temperature was 25 °C, and the mass fraction of K2O in the obtained crystals was 58.99%.


2015 ◽  
Vol 10 ◽  
pp. ACI.S31727 ◽  
Author(s):  
Niki Tsartsali ◽  
Victoria F. Samanidou

A quick, easy, cheap, effective, rugged, and safe (QuEChERS) dispersive extraction method is proposed herein for the isolation and cleanup of melamine and cyromazine from chicken egg yolk. Analytes are determined by high-performance liquid chromatography using photodiode array detector after separation on a LiChroCART® (250 × 4 mm)–-LiChrospher® RP-8e, 5 µm analytical column using a mobile phase of 0.1% trifluoracetic acid and methanol (80:20 v/v) delivered isocratically at a flow rate of 1 mL/minute. Extraction of isolated compounds was achieved by methanol and acetonitrile mixture (1:1 v/v). Recovery rates ranged between 74.5% and 115.8%. The method was validated in terms of 657/2002/EC decision. The within-laboratory reproducibility, expressed as a relative standard deviation, was <11%. Decision limits (CCalfa) were 2.56 mg/kg for melamine and 0.22 mg/kg-1 for cyromazine, and the corresponding results for detection capability (CCbeta) were 2.8 mg/kg for melamine and 0.24 mg/kg for cyromazine. Ruggedness was estimated according to the Youden approach studying egg yolk mass, sorbent mass, centrifugation time, organic solvents volume, evaporation temperature, and vortex time.


Sign in / Sign up

Export Citation Format

Share Document