scholarly journals Compound Comminuted Fracture of the Hip Followed by Bony Union and Movable Joint

1909 ◽  
Vol LII (14) ◽  
pp. 1123
Author(s):  
James E. Moore
2015 ◽  
Vol 43 (01) ◽  
pp. 44-38
Author(s):  
C.-C. Lin ◽  
K.-S. Chen ◽  
Y.-L. Lin ◽  
J. P.-W. Chan

SummaryA 5-month-old, 13.5 kg, female Corriedale sheep was referred to the Veterinary Medicine Teaching Hospital, with a history of traumatic injury of the cervical spine followed by non-ambulatoric tetraparesis that occurred 2 weeks before being admitted to the hospital. At admission, malalignment of the cervical spine with the cranial part of the neck deviating to the right was noted. Neurological examinations identified the absence of postural reactions in both forelimbs, mildly decreased spinal reflexes, and normal reaction to pain perception tests. Radiography revealed malalignment of the cervical vertebrae with subluxations at C1–C2 and C2–C3, and a comminuted fracture of the caudal aspect of C2. The sheep was euthanized due to a presumed poor prognosis. Necropsy and histopathological findings confirmed injuries of the cervical spine from C1 to C3, which were consistent with the clinical finding of tetraparesis in this case. This paper presents a rare case of multiple subluxations of the cervical spine caused by blunt force trauma in a young sheep. These results highlight the importance of an astute clinical diagnosis for such an acute cervical spine trauma and the need for prompt surgical correction for similar cases in the future.


1998 ◽  
Vol 02 (04) ◽  
pp. 325-332
Author(s):  
Shigeru Hirabayashi ◽  
Kiyoshi Kumano ◽  
Takeshi Uchida

We developed a new method of posterior lumbar interbody fusion (PLIF) using an en-bloc resected lamina with or without a hydroxyapatite block as an interbody spacer instead of auto-iliac bone, in combination with rigid-type spinal instrumentation. The purpose of this study was to evaluate the effectiveness of our method. There were 23 patients (13 males, 10 females, age at the time of operation: 21–71 years, mean 50.5 years; follow-up: 1–4 years, mean 2 years and 3 months). In 10 patients with spondylolitic spondylolisthesis and 3 patients with spondylolysis, the floating lamina was resected enbloc by mid-line splitting. In 7 patients with degenerative spondylolisthesis and 3 patients with unstable spine, a cleavage was made at the isthmus and then the complex of lamina and inferior spinous process was resected en-bloc. Seventeen patients with olisthesis underwent reduction. PLIF was performed at the L4/L5 level in 10 patients and the L5/S1 level in 13 patients. Sixteen patients with preoperative low back pain recovered, except for one patient with instability at the adjacent vertebra. All of the seven patients with preoperative gait disturbance recovered. The ratio of olisthesis changed from preoperative 30% to postoperative 18% on average. Good bony union was obtained in both the patients with and those without a hydroxyapatite spacer. Posterior lumbar interbody fusion using an en-bloc resected lamina as an interbody spacer in combination with rigid-type spinal instrumentation was useful.


1988 ◽  
Vol 36 (4) ◽  
pp. 1338-1341
Author(s):  
Tetsuo Nakano ◽  
Muneyoshi Kawaguchi ◽  
Takashi Ikeda ◽  
Teiji Kato
Keyword(s):  

Injury ◽  
1983 ◽  
Vol 15 (1) ◽  
pp. 53-56 ◽  
Author(s):  
G. Lyritis ◽  
Th. Ioannidis ◽  
G. Hartofylakidis-Garofalidis
Keyword(s):  

2021 ◽  
Vol 53 (05) ◽  
pp. 462-466
Author(s):  
Jun-Ku Lee ◽  
Soonchul Lee ◽  
SeongJu Choi ◽  
Dong Hun Han ◽  
Jongbeom Oh ◽  
...  

Abstract Purpose To report the clinical and radiographic results of arthrodesis of relatively small-sized distal interphalangeal joints (DIPJs) using only K-wire fixation. Patients and methods Between January 2000 and December 2018 28 arthrodesis in 21 patients (9 males and 12 females with an average age of 52.1 years) with relatively small-sized DIPJs were performed using only K-wires. Data on patient’s characteristics, such as age, sex, affected finger, and the number and size of the used k-wires were collected from the medical database. The narrowest diameter of the cortex and medulla of the distal phalanx was measured on preoperative plain radiographs. The time to union and the arthrodesis angle was determined using serial X-ray radiography follow-up. Preoperatively and at the latest follow-up examination, pain using the visual analogue scale (VAS) and the quick DASH score was registered. In addition, complications were investigated. Results Average follow-up period was 11.4 months. The small finger was mostly affected (n = 12; 42.9 %). The narrowest diameters of the distal phalanx cortex and the medulla measured on preoperative X-ray images were 2.8 mm (SD 0.5) and 1.2 mm (SD 0.4), respectively. Seven fusions were done with use of 1 K-wire, 20 with 2 (71.4 %), and 1 with 3 K-wires. The most common K-wire sizes were 1.1-inch (24 K-wires = 48 %), and 0.9 inch (21 K-wires = 42 %) The preoperative VAS score and quick DASH score improved from 6.1 (range: 0–9) and 25.8 (range: 2–38) to 0.4 (range: 0–2) and 3.4 (range: 0–10.2), respectively. 25 (89.3 %) out of 28 fingers achieved bony union in an average of 96.1 days (range: 58–114) with three non-union. Conclusion Arthrodesis of small DIPJs with K-wire fixation has a high success rate. Therefore, we suggest K-wire fixation as an acceptable alternative for patients with a small phalanx which may be at risk of mismatch with bigger implants. However, concerns remain in terms of fusion delay with K-wire only fixation.


Sign in / Sign up

Export Citation Format

Share Document