Distal interphalangeal Joint Arthrodesis using only Kirschner Wires in small distal Phalanges

2021 ◽  
Vol 53 (05) ◽  
pp. 462-466
Author(s):  
Jun-Ku Lee ◽  
Soonchul Lee ◽  
SeongJu Choi ◽  
Dong Hun Han ◽  
Jongbeom Oh ◽  
...  

Abstract Purpose To report the clinical and radiographic results of arthrodesis of relatively small-sized distal interphalangeal joints (DIPJs) using only K-wire fixation. Patients and methods Between January 2000 and December 2018 28 arthrodesis in 21 patients (9 males and 12 females with an average age of 52.1 years) with relatively small-sized DIPJs were performed using only K-wires. Data on patient’s characteristics, such as age, sex, affected finger, and the number and size of the used k-wires were collected from the medical database. The narrowest diameter of the cortex and medulla of the distal phalanx was measured on preoperative plain radiographs. The time to union and the arthrodesis angle was determined using serial X-ray radiography follow-up. Preoperatively and at the latest follow-up examination, pain using the visual analogue scale (VAS) and the quick DASH score was registered. In addition, complications were investigated. Results Average follow-up period was 11.4 months. The small finger was mostly affected (n = 12; 42.9 %). The narrowest diameters of the distal phalanx cortex and the medulla measured on preoperative X-ray images were 2.8 mm (SD 0.5) and 1.2 mm (SD 0.4), respectively. Seven fusions were done with use of 1 K-wire, 20 with 2 (71.4 %), and 1 with 3 K-wires. The most common K-wire sizes were 1.1-inch (24 K-wires = 48 %), and 0.9 inch (21 K-wires = 42 %) The preoperative VAS score and quick DASH score improved from 6.1 (range: 0–9) and 25.8 (range: 2–38) to 0.4 (range: 0–2) and 3.4 (range: 0–10.2), respectively. 25 (89.3 %) out of 28 fingers achieved bony union in an average of 96.1 days (range: 58–114) with three non-union. Conclusion Arthrodesis of small DIPJs with K-wire fixation has a high success rate. Therefore, we suggest K-wire fixation as an acceptable alternative for patients with a small phalanx which may be at risk of mismatch with bigger implants. However, concerns remain in terms of fusion delay with K-wire only fixation.

2019 ◽  
Vol 21 (6) ◽  
pp. 417-426
Author(s):  
Kamil Yamak ◽  
Hüseyin Gökhan Karahan ◽  
Taşkın Altay ◽  
Cemil Kayalı ◽  
Fırat Ozan

Background. The aim of this study was to evaluate the clinical and radiographic results of surgical treatment of irreparable rotator cuff tears by subacromial balloon spacer insertion in patients over 65 years old. Material and methods. Results of patients with failed conservative treatment for irreparable rotator cuff tears and who underwent subacromial balloon spacer insertion were evaluated retrospectively. The VAS and Quick-DASH scores were used for clinical and functional assessment. Results. Eleven patients were included. Mean age of patients was 69.1 (range: 65-77) years old. Evaluation of anteroposterior shoulder x-rays revealed Hamada grade 2 and grade 1 arthropathy in 10 patients (91%) and 1 patient (9%),respectively. Mean duration of follow-up was 45.09 (±5.43,37-52) months. The difference in the subacromial space measured from standard AP shoulder x-rays in the preoperative period, in the 6th postoperative month, and at the end of follow-up was 5.44 mm (2.29), 6.51 mm (±2.23), and 5.08 mm (±2.13), respectively. Mean Quick-DASH score was 74.49(±14.36) in the preoperative period, compared to 72.19 (±14.38) at the end of follow-up. There was no statistically significant difference between preoperative period and end of follow-up scores in terms of mean Quick-DASH scores (p= 0.232). Mean VAS score was 7.09 (±0.831) in the preoperative period and 6.64 (±0.809) at the end of follow-up. No statistically significant difference was revealed in terms of mean VAS scores when preoperative and end of follow-up scores were compared (p=0.333). Conclusion. Clinical and radiographic results of subacromial balloon spacer insertion in the treatment of irreparable rotator cuff tears could not be evaluated as satisfactory.


2020 ◽  
Author(s):  
Zhaofeng Jia ◽  
Shijin Wang ◽  
Wei Jiang ◽  
Chuangli Li ◽  
Jiandong Lin ◽  
...  

Abstract Background: Although distal radius fractures (DRFs) are clinically common, DRFs accompanied by dorsally displaced free fragments beyond the watershed line are much less so. At present, it is very difficult to fix and stabilize the displaced free fragments far away from the watershed line with a plate. Our aim was to investigate the clinical effect of DRFs with distally displaced dorsal free mass treated with distal volaris radius (DVR) combined with turning of the radius via the distal palmar approach. Methods: From 2015 to 2019, 25 patients with distal radius fractures associated with dorsally displaced free fragments beyond the watershed line were selected and treated with distal volaris radius (DVR) combined with turning of the radius via the distal palmar approach. This study involved 14 males and 11 females, with an average age of 34.5 years (ranging from 21 to 50 years). The mean follow-up period was 16.5 months (ranging from 12 to 22 months). The dorsal displacement of the free fragments was analyzed by X-ray and three-dimensional computed tomography, allowing characterization of postoperative recovery effects by radial height, volar tilt and radial inclination. For the follow-up, we evaluated effects of the surgery by analyzing range of motion (ROM); Modified Mayo Wrist Score (MMWS); and Disabilities of Arm, Shoulder and Hand (DASH) score. Postoperative wound recovery and complications were also monitored to evaluate the clinical therapeutic effects of the surgical procedures. Results: X-ray showed that all patients showed reduced fractures, well-healed wounds and recovered function with no obvious complications. Based on the follow-up, patients had a mean radial height of 10.5mm (ranging from 8.1 to 12.6 mm), mean MMWS of 78.8° (ranging from 61 to 90°), mean DASH score of 16.25 (ranging from 11 to 21), mean ROM for volar flexion of 76.5° (ranging from 62 to 81°), mean ROM for dorsiflexion of 77.1° (ranging from 59 to 83) and mean VAS score of 1.4 (ranging from 1 to 3). Conclusion: Treatment of distal radius fractures with accompanying dorsally displaced free fragments beyond the watershed line with turning of the radius and the DVR plate system via the distal palmar approach is effective and has no obvious complications.


2012 ◽  
Vol 15 (1) ◽  
pp. 32-36 ◽  
Author(s):  
Chul Hyun Cho ◽  
Hyung Gyu Jang

PURPOSE: The purpose of this study was to evaluate the radiologic and clinical outcomes after intercalary tricortical iliac bone graft with plate fixation for the nonunion of midshaft clavicular fractures.MATERIALS AND METHODS: Between September 2007 and May 2011, 10 patients who were treated by the intercalary tricortical iliac bone graft, with plate fixation for clavicle nonunion, were studied. The mean follow-up period was 30.7 (12~57) months. After the sclerotic bone was excised to the bleeding cortical bone, we interposed the tricortical iliac bone to provide structural support and restore clavicle length, and then fixed the plate and screws. The radiologic outcomes on the serial plain radiographs and clinical outcomes, according to UCLA, ASES and Quick DASH scores, were analyzed.RESULTS: Bony union was obtained in all cases (100%) and the average union time was 18.4 (14~24) weeks. The average respective UCLA and ASES scores improved from 16.7 and 52.1 preoperatively to 27.4 and 83.6 postoperatively (p<0.05). The average Quick DASH score was 40.5, at the final follow-up. Complications were 2 shoulder stiffness, and one case had removal of device and arthroscopic surgery at 11 months, postoperatively. There were no implant failure or infection.CONCLUSION: Intercalary tricortical iliac bone graft, with plate fixation for the nonunion of midshaft clavicular fractures, is a good option that can provide structural support and restore clavicle length, as well as high union rate.


2021 ◽  
Vol 26 (3) ◽  
pp. 171-173
Author(s):  
Kyung Jin Lee ◽  
Jung Hyun Park ◽  
Sung Hoon Koh ◽  
Dong Chul Lee ◽  
Si Young Roh ◽  
...  

Kirschner wire (K-wire) has been widely used for treatment of fracture for its cost-effectiveness and reliability. This case presents the K-wire breakage in distal interphalangeal joint (DIPJ) fixation. A 55-year-old male patient was injured by a knife and showed rupture of extensor tendon at 1/2 of middle phalanx. A 0.9-mm K-wire was implemented for DIPJ extension, and tenorrhaphy was done. After 6 weeks, we detected breakage of K-wire in the follow-up X-ray. The broken K-wire in the distal phalanx was removed. We removed the remaining K-wire through an incision on volar side of middle phalanx under C-arm after 2 weeks for the patient’s personal reasons. Breakage during postoperative K-wire maintenance is exceedingly rare. This patient is presumed to have ruptured because he continued using his finger. Therefore, while K-wire is present, continued use of finger without protection may cause breakage, so protective measures such as splint are required.


2020 ◽  
Author(s):  
Binod Sherchan ◽  
Saroj Rai ◽  
Nira Tamang ◽  
Siddhartha Dhungana ◽  
Laxmi Kanta Sharma ◽  
...  

Abstract Background The primary aim of this study was to compare the clinical outcomes of patients undergoing arthroscopic Bankart repair and open Latarjet procedure for recurrent dislocation of the shoulder. Secondary aims were to assess and compare the cost-effectiveness, satisfaction and complications, including recurrence and infection. Methods We retrospectively evaluated the patients who underwent either arthroscopic Bankart repair with or without Remplissage procedure or open Latarjet procedure between May 2015 and May 2018. The preoperative data were collected from the hospital records, and the postoperative data were collected during the follow-up visit. At the final follow-up, 41(male=32, female=9) patients in the Bankart group and 40(male=34 and female=6) patients in the Latarjet group were included in the study. Clinical outcomes were assessed using the ASES score, Rowe score, and Quick DASH score. A self-constructed scale that consisted of satisfied and dissatisfied was used to measure the level of satisfaction. Any complications were recorded in every follow-up visit. Collected data were analyzed using SPSS version 25. Results There was no statistically significant difference regarding the age (p=0.401), gender (p=0.569), site of involvement (p=0.158), number of preoperative dislocations (p=0.085), follow-up (p=0.061), between the two groups. Similarly, no statistically significant difference existed regarding the ASES score (p=0.388), Rowe score (p=0.211), and Quick DASH score (p=0.713). The average external rotation was 83 degrees in the Bankart group and 85 degrees in the Latarjet group (p=0.140). Functional satisfaction was higher in the Laterjet group compared to the Bankart group (p=0.482). Hundred percent of the patients were cosmetically satisfied in the Bankart group, whereas only 32(80%) patients were cosmetically satisfied in the Latarjet group (p=0.002). There was a significantly higher operating cost for arthroscopic Bankart repair compared to open Latarjet procedure (p<0.001). Three patients had a recurrence in the Bankart group, whereas no recurrence occurred in the Latarjet group. And, 2 superficial infections occurred in the Latarjet group. Conclusion These results provide the fact that arthroscopic Bankart repair might be a fancy and minimally invasive procedure, Latarjet procedure should still be a priority in a developing country like Nepal, where financial cost is a huge burden.


2020 ◽  
Vol 23 (4) ◽  
pp. 183-189
Author(s):  
Chung-Sin Baek ◽  
Beom-Soo Kim ◽  
Du-Han Kim ◽  
Chul-Hyun Cho

Background: The purpose of the current study was to investigate short- to mid-term outcomes and complications following radial head replacement (RHR) for complex radial head fractures and to identify factors associated with clinical outcomes.Methods: Twenty-four patients with complex radial head fractures were treated by RHR. The mean age of the patients was 49.8 years (range, 19–73 years). Clinical and radiographic outcomes were evaluated for a mean follow-up period of 58.9 months (range, 27–163 months) using the visual analog scale (VAS) score for pain, the Mayo elbow performance score (MEPS), the quick disabilities of the arm, shoulder and hand (Quick-DASH) score, and serial plain radiographs. Complications were also evaluated. Results: At the final follow-up, the mean VAS score, MEPS, and Quick-DASH score were 0.6±1.1, 88.7±11.5, and 19.4±7.8, respectively. The mean range of motion was 132.7o of flexion, 4.7o of extension, 76.2o of pronation, and 77.5o of supination. Periprosthetic lucency was observed in six patients (25%). Heterotopic ossification was observed in four patients (16.7%). Arthritic change of the elbow joint developed in seven patients (29.2%). Capitellar wear was found in five patients (20.8%). Arthritic change of the elbow joint was significantly correlated with MEPS (P=0.047). Four cases of complications (16.6%) were observed, including two cases of major complications (one stiffness with heterotopic ossification and progressive ulnar neuropathy and one stiffness) and two cases of minor complications (two transient ulnar neuropathy).Conclusions: RHR for the treatment of complex radial head fractures yielded satisfactory short- to mid-term clinical outcomes, though radiographic complications were relatively high.


2021 ◽  
Author(s):  
Jun Li ◽  
Xin Tan ◽  
Xiang Li ◽  
Pan Gou ◽  
Xiaowei Yuan ◽  
...  

Abstract Purpose: Most of humeral shaft fractures in children could be treated satisfactorily by conservative treatment. This study aimed to evaluate the application value of ultrasonography in conservative treatment of humeral shaft fracture in children.Methods: We retrospectively reviewed children admitted to our hospital, for humeral shaft fracture from January 2014 to March 2018. The patients were divided into two groups: ultrasonography group and X-ray group. All patients were instructed to re-examined at 1 week, 2 weeks, 4 weeks, 12 weeks, 24 weeks and 1 year from the injury date for follow-up, and evaluated the prognosis according to the Disabilities of Arm, Shoulder and Hand (DASH) score at 12 months.Results: A total of 37 children were divided into ultrasonography group, 32 children were divided into X-ray group. There was no significant difference in prognosis between the two groups. The mean number of radiation exposures of ultrasonography group was less and ultrasonic examination found radial nerve injury, and using ultrasound reduced the chance of direct or in direct contact with infected peoples.Conclusion: Ultrasound is a non-invasive, non-radioactive test, which could decrease risk of COVID-19 infection and detect the vascular nerve injury caused by fracture. Ultrasonography may be the examination method for follow-up conservative treatment of humeral shaft fracture in children during the epidemic period.


2022 ◽  
Vol 30 (1) ◽  
pp. 230949902110670
Author(s):  
Young-Keun Lee

Purpose To report the arthroscopic and clinical findings of patients with extensor carpi ulnaris (ECU) tendinopathy treated with wrist arthroscopy and open surgical repair. Methods We retrospectively reviewed the medical records of seven patients with chronic ECU tendinopathy who were treated with diagnostic wrist arthroscopy and open surgical repair between 2010 and 2017. Seven cases diagnosed with ECU tendinopathy had undergone open procedure for the ECU tendinopathy, as well as wrist arthroscopy in the same session. Any pathology of the triangular fibrocartilage complex (TFCC) diagnosed by wrist arthroscopy were treated simultaneously with open procedure for the ECU tendinopathy. The functional outcome was evaluated by comparing the preoperative and final follow-up values of range of motion (ROM), grip strength, visual analog scale (VAS) for pain, modified Mayo wrist score and quick disabilities of the arm, shoulder, and hand (DASH) score. Results TFCC tears were identified in four patients of which repair was performed concomitantly. The average follow-up period was 39 months (range, 25–49 months). At the final follow-up, all the outcomes including average VAS score (6.4→1), the ROM (173→192°), quick DASH score (42.5→18.2), and modified Mayo wrist score (48.6→79.3) improved significantly. Conclusion When treating patients with ECU tendinopathy, the possibility of TFCC combined injury should always be considered. If surgical treatment is planned, we suggest a wrist arthroscopy for more accurate diagnosis an intra-articular pathology, particularly for patients whose MRI findings suggest a degenerative tear or degeneration at the periphery of the TFCC. Additionally, if ECU and DRUJ stability is obtained by repair or reconstruction of the concurrent pathologies in the ECU subsheath, TFCC and other intra-articular structures, the results will be favorable.


2020 ◽  
pp. 175857322097209
Author(s):  
Charles I Ayekoloye ◽  
Qi Yin ◽  
Amanda Wood ◽  
Simon Frostick

Introduction Symptomatic sternoclavicular osteoarthritis is uncommon but remains the most frequent non-traumatic condition affecting the sternoclavicular joint and tends to have a predilection for middle-aged women. It responds well to conservative management. Surgery is indicated when conservative management fails. We present the clinical outcome of open symptomatic sternoclavicular osteophyte debridement, a new operation for treating recalcitrant symptomatic sternoclavicular osteoarthritis. Methods Five patients (five symptomatic sternoclavicular joints) with symptomatic sternoclavicular osteoarthritis underwent open sternoclavicular debridement following failure of conservative treatment. There were three females and two males. Mean age was 46.6 years (range 37.17–66). Four cases were primary osteoarthritis and one case was secondary to trauma. They were reviewed at mean follow-up at 35.4 months with minimum follow-up of 29 months. Assessment included Quick Disabilities of Arm Shoulder and Hand (DASH) and subjective patient satisfaction score. Results There was no post-operative complication. Mean Quick DASH score 10.9 (range 0–29.5) at mean 35.4-month follow-up (range 29–43 months). Three patients reported excellent and two reported good outcome as per subjective satisfaction score. Conclusions Open sternoclavicular debridement has proved to be a simple, safe and highly effective new surgical treatment for patients with symptomatic sternoclavicular osteoarthritis unresponsive to non-operative management.


2018 ◽  
Vol 12 (1) ◽  
pp. 53-58 ◽  
Author(s):  
Miltiadis Argyropoulos ◽  
Matthew Kent

Background: Open reduction internal fixation of displaced 3 and 4-part proximal humerus fractures is an effective treatment modality particularly for the younger age group, but it is not without complications. Fixed angled locking screw plates are the mainstay of fixation. The A.L.P.S. Proximal Humerus Plating System is a new implant that has smooth locking pegs in the place of humeral head screws to help reduce glenoid damage in the event of cut-out and is designed to sit low on the humerus in order to reduce the risk of subacromial impingement. Methods: Retrospective analysis of 15 consecutive patients who sustained closed displaced 3-part or 4-part fractures and had fixation surgery using the A.L.P.S. plate. Outcome measures were the time to radiographic and clinical union, Oxford Shoulder Score, quick DASH score and complications. Results: Average follow-up was 31.9 weeks. Union was achieved in 100% of patients with a mean time to union of 15.1 weeks. In terms of function, mean OSS was 33.6 and mean quick DASH was 32.5. There were no instances of AVN. Conclusion: Our preliminary results of 15 patients followed up for a mean of 31.9 weeks show equitable union rates and time to union as well as functional scores compared to other available plating systems. This is the first study to report on this implant to date.


Sign in / Sign up

Export Citation Format

Share Document