Concentration of Mycobacterium avium by hospital hot water systems

JAMA ◽  
1988 ◽  
Vol 260 (11) ◽  
pp. 1599-1601 ◽  
Author(s):  
G. C. du Moulin
2018 ◽  
Vol 69 (1) ◽  
pp. 46-54 ◽  
Author(s):  
Dolores Peruč ◽  
Ivana Gobin ◽  
Maja Abram ◽  
Dalibor Broznić ◽  
Tomislav Svalina ◽  
...  

Abstract Mycobacterium avium complex-related diseases are often associated with poorly maintained hot water systems. This calls for the development of new control strategies. The aim of this study was to investigate the activity of essential oils (EOs) from the Mediterranean plants, common juniper, immortelle, sage, lavandin, laurel, and white cedar against Mycobacterium avium ssp. avium, Mycobacterium intracellulare, and Mycobacterium gordonae in culturing broth and freshwater as their most common habitat. To do that, we developed a new method of water microdilution to determine their minimal effective concentrations (MEC). The most active EO was the one from the common juniper with the MEC of 1.6 mg mL-1. Gas chromatography / mass spectrometry the juniper EO identified monoterpenes (70.54 %) and sesquiterpenes (25.9 %) as dominant component groups. The main monoterpene hydrocarbons were α-pinene, sabinene, and β-pinene. The juniper EO significantly reduced the cell viability of M. intracellulare and M. gordonae at MEC, and of M. avium at 2xMEC. Microscopic analysis confirmed its inhibitory effect by revealing significant morphological changes in the cell membrane and cytoplasm of all three bacteria. The mode of action of the juniper EO on the cell membrane was confirmed by a marked leakage of intracellular material. Juniper EO has a great practical potential as a complementary or alternative water disinfectant in hot water systems such as baths, swimming pools, spa pools, hot tubs, or even foot baths/whirlpools.


1987 ◽  
Vol 109 (2) ◽  
pp. 150-155 ◽  
Author(s):  
M. P. Malkin ◽  
S. A. Klein ◽  
J. A. Duffie ◽  
A. B. Copsey

A modification to the f-Chart method has been developed to predict monthly and annual performance of thermosyphon solar domestic hot water systems. Stratification in the storage tank is accounted for through use of a modified collector loss coefficient. The varying flow rate throughout the day and year in a thermosyphon system is accounted for through use of a fixed monthly “equivalent average” flow rate. The “equivalent average” flow rate is that which balances the thermosyphon buoyancy driving force with the frictional losses in the flow circuit on a monthly average basis. Comparison between the annual solar fraction predited by the modified design method and TRNSYS simulations for a wide range of thermosyphon systems shows an RMS error of 2.6 percent.


1999 ◽  
Vol 28 (6) ◽  
pp. 309-313 ◽  
Author(s):  
T.S. Gill ◽  
R.J. Knapp ◽  
S.W. Bradley ◽  
W.L. Bradley