Assessment of bioresorbable scaffold with a novel high‐definition 60 MHz IVUS imaging system: Comparison with 40‐MHz IVUS referenced to optical coherence tomography

2017 ◽  
Vol 91 (5) ◽  
pp. 874-883 ◽  
Author(s):  
Kozo Okada ◽  
Hideki Kitahara ◽  
Yoshiaki Mitsutake ◽  
Shigemitsu Tanaka ◽  
Takumi Kimura ◽  
...  
The Analyst ◽  
2020 ◽  
Vol 145 (4) ◽  
pp. 1445-1456 ◽  
Author(s):  
Fabian Placzek ◽  
Eliana Cordero Bautista ◽  
Simon Kretschmer ◽  
Lara M. Wurster ◽  
Florian Knorr ◽  
...  

Characterization of bladder biopsies, using a combined fiber optic probe-based optical coherence tomography and Raman spectroscopy imaging system that allows a large field-of-view imaging and detection and grading of cancerous bladder lesions.


2021 ◽  
pp. 247412642199733
Author(s):  
Kyle D. Kovacs ◽  
M. Abdallah Mahrous ◽  
Luis Gonzalez ◽  
Benjamin E. Botsford ◽  
Tamara L. Lenis ◽  
...  

Purpose: This work aims to evaluate the clinical utility and feasibility of a novel scanning laser ophthalmoscope-based navigated ultra-widefield swept-source optical coherence tomography (UWF SS-OCT) imaging system. Methods: A retrospective, single-center, consecutive case series evaluated patients between September 2019 and October 2020 with UWF SS-OCT (modified Optos P200TxE, Optos PLC) as part of routine retinal care. The logistics of image acquisition, interpretability of images captured, nature of the peripheral abnormality, and clinical utility in management decisions were recorded. Results: Eighty-two eyes from 72 patients were included. Patients were aged 59.4 ± 17.1 years (range, 8-87 years). During imaging, 4.4 series of images were obtained in 4.1 minutes, with 86.4% of the image series deemed to be diagnostic of the peripheral pathology on blinded image review. The most common pathologic findings were chorioretinal scars (18 eyes). In 31 (38%) eyes, these images were meaningful in supporting clinical decision-making with definitive findings. Diagnoses imaged included retinal detachment combined with retinoschisis, retinal hole with overlying vitreous traction and subretinal fluid, vitreous inflammation overlying a peripheral scar, Coats disease, and peripheral retinal traction in sickle cell retinopathy. Conclusions: Navigated UWF SS-OCT imaging was clinically practical and provided high-quality characterization of peripheral retinal lesions for all eyes. Images directly contributed to management plans, including laser, injection or surgical treatment, for a clinically meaningful set of patients (38%). Future studies are needed to further assess the value of this imaging modality and its role in diagnosing, monitoring, and treating peripheral lesions.


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Yi Sun ◽  
Jianfeng Wang ◽  
Jindou Shi ◽  
Stephen A. Boppart

AbstractPolarization-sensitive optical coherence tomography (PS-OCT) is a high-resolution label-free optical biomedical imaging modality that is sensitive to the microstructural architecture in tissue that gives rise to form birefringence, such as collagen or muscle fibers. To enable polarization sensitivity in an OCT system, however, requires additional hardware and complexity. We developed a deep-learning method to synthesize PS-OCT images by training a generative adversarial network (GAN) on OCT intensity and PS-OCT images. The synthesis accuracy was first evaluated by the structural similarity index (SSIM) between the synthetic and real PS-OCT images. Furthermore, the effectiveness of the computational PS-OCT images was validated by separately training two image classifiers using the real and synthetic PS-OCT images for cancer/normal classification. The similar classification results of the two trained classifiers demonstrate that the predicted PS-OCT images can be potentially used interchangeably in cancer diagnosis applications. In addition, we applied the trained GAN models on OCT images collected from a separate OCT imaging system, and the synthetic PS-OCT images correlate well with the real PS-OCT image collected from the same sample sites using the PS-OCT imaging system. This computational PS-OCT imaging method has the potential to reduce the cost, complexity, and need for hardware-based PS-OCT imaging systems.


2014 ◽  
Vol 8 (8) ◽  
pp. 681-686 ◽  
Author(s):  
Thilo Gambichler ◽  
Iris Plura ◽  
Monika Schmid-Wendtner ◽  
Konstantinos Valavanis ◽  
Daniela Kulichova ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document