Combined Use of Unguided FNA and CNB Increases the Diagnostic Accuracy for Palpable Breast Lesions

2016 ◽  
Vol 44 (7) ◽  
pp. 578-581 ◽  
Author(s):  
Areej Al Nemer
1997 ◽  
Vol 36 (08) ◽  
pp. 282-288 ◽  
Author(s):  
T. Atasever ◽  
A. Özdemir ◽  
I. Öznur ◽  
N. I. Karabacak ◽  
N. Gökçora ◽  
...  

Summary Aim: Our goal was to determine the clinical usefulness of TI-201 to identify breast cancer in patients with suspicious breast lesions on clinical examination, and/or abnormal radiologic (mammography and/or ultrasonography) findings. Methods: TI-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of TI-201. Visual and semiquantitative interpretation was performed. Results: Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. TI-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by TI-201 scintigraphy. The smallest mass lesion detected by TI-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. TI-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed TI-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated TI-201. TI-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by TI-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58 ± 0.38 (mean ± SD) and 1.48 ± 0.32 (p >0.05), 1.87 ± 0.65 and 1.34 ± 0.20 (p<0.05) respectively. The mean early and late L/N ratios of malignant and benign groups did not show statistical difference (p>0.05). Conclusion: Overall, TI-201 scintigraphy was the most specific of the three methods and yielded favourable results in palpable breast cancers, while it showed lower sensitivity in nonpalpable cancers and axillary metastases. Combined use of TI-201 scintigraphy with mammography and US seems to be useful in difficult cases, such as dense breasts and indeterminate breast lesions.


1984 ◽  
Vol 25 (4) ◽  
pp. 273-276 ◽  
Author(s):  
M. Kehler ◽  
U. Albrechtsson

Results with a previously described device for fine needle biopsies of non-palpable breast lesions are reported. During the past 5 years 182 biopsies were performed and 133 of these yielded diagnostic cell material. In the series, 41 carcinomas were found and fine needle biopsy in all demonstrated malignant or probably malignant cells. In the biopsies evaluated as benign or probably benign, malignancy has not been found during the observation period of 4 to 59 months (mean 21.5 months). The device described is cheap and biopsy is easily performed and, if necessary, repeated in a short time. The diagnostic accuracy is high and carcinomas as small as 3 mm in diameter have been diagnosed.


1994 ◽  
Vol 190 (1) ◽  
pp. 69-76 ◽  
Author(s):  
S. Bianchi ◽  
D. Palli ◽  
M. Galli ◽  
B. Arisio ◽  
A. Cappal ◽  
...  

2020 ◽  
Vol 5 (3) ◽  
pp. 1196-1200
Author(s):  
Manish Raj Pathak ◽  
Mahesh Gautam ◽  
Rashmita Bhandari

Introduction: Breast carcinoma is the second leading cause of cancer related mortality in females around the world. Ultrasound plays a key role in differentiating cystic and solid lesions and is a convenient and non-invasive diagnostic tool to differentiate between benign and malignant lesions. Objectives: The aim of this study is to evaluate the diagnostic accuracy of ultrasound in palpable breast lesions. Methodology: A prospective cross-sectional study was carried out in patients with palpable breast lesions who presented in Department of radio diagnosis and imaging of Nobel Medical collegefor a period of one-year from February 2019- January 2020 using ultrasound. A total of 60 patientswereevaluated in the study. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. Results: Out of 60 patients evaluated, ultrasound showed 46 (76.7%) cases to be benign and 14 (23.3%) cases to be malignant. FNAC revealed benign disease in 47 (78.3%) patients and malignant disease in 13 (21.7%) patients. The most common benign lesion was fibroadenoma. We found nearly 91.7% of the malignant lesions had spiculated margins and microcalcification. The sensitivity of ultrasound was 95.74% and specificity 92.3% with diagnostic accuracy 95%. Conclusion: Ultrasound is a convenient and non-invasive diagnostic tool with good sensitivity, specificity, positive predictive value, negative predictive value and accuracy in palpable breast lesions.


1997 ◽  
Vol 24 (2) ◽  
pp. 120-123 ◽  
Author(s):  
Ruud M. Pijnappel ◽  
Albert van Dalen ◽  
Inne H.M. Borel Rinkes ◽  
Jan G. van den Tweel ◽  
Willem P.Th.M. Mali

1995 ◽  
Vol 169 (5) ◽  
pp. 519-522 ◽  
Author(s):  
John Vetto ◽  
Rodney Pommier ◽  
Waldemar Schmidt ◽  
Mitchell Wachtel ◽  
Polly DuBois ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document