scholarly journals Whole-brain vessel wall MRI: A parameter tune-up solution to improve the scan efficiency of three-dimensional variable flip-angle turbo spin-echo

2017 ◽  
Vol 46 (3) ◽  
pp. 751-757 ◽  
Author(s):  
Qi Yang ◽  
Zixin Deng ◽  
Xiaoming Bi ◽  
Shlee S. Song ◽  
Konrad H. Schlick ◽  
...  
2010 ◽  
Vol 21 (2) ◽  
pp. 402-410 ◽  
Author(s):  
Jérôme Hodel ◽  
Jonathan Silvera ◽  
Olivier Bekaert ◽  
Alain Rahmouni ◽  
Sylvie Bastuji-Garin ◽  
...  

2010 ◽  
Vol 31 (3) ◽  
pp. 645-654 ◽  
Author(s):  
Zhaoyang Fan ◽  
Zhuoli Zhang ◽  
Yiu-Cho Chung ◽  
Peter Weale ◽  
Sven Zuehlsdorff ◽  
...  

2014 ◽  
Vol 41 (2) ◽  
pp. 339-346 ◽  
Author(s):  
Yukihisa Takayama ◽  
Akihiro Nishie ◽  
Yoshiki Asayama ◽  
Yasuhiro Ushijima ◽  
Nobuhiro Fujita ◽  
...  

2021 ◽  
Author(s):  
Koji Matsumoto ◽  
Hajime Yokota ◽  
Takafumi Yoda ◽  
Ryota Ebata ◽  
Hiroki Mukai ◽  
...  

Abstract Background: Magnetic resonance vessel wall imaging is desirable for evaluating Kawasaki disease (KD)-associated coronary arterial lesions. Purpose: To evaluate reproducibility of three-dimensional turbo spin-echo (3D-TSE) and two-dimensional dual inversion-recovery turbo spin-echo (2D-DIR-TSE) for coronary vessel wall imaging in KD.Methods: Ten patients were prospectively enrolled. Coronary vessel wall imaging with axial-slice orientation 3D-TSE and 2D-DIR-TSE were acquired for cross-sectional images in aneurysmal and normal regions. Lumen area (LA), wall area (WA), and normalized wall index (NWI) of cross-sectional images were measured in both regions. Reproducibility between 3D-TSE and 2D-DIR-TSE was evaluated via intraclass correlation coefficients (ICCs) and Bland-Altman plots.Results: 48 points (aneurysmal, 27; normal, 21) were evaluated. There were high ICCs between 3D-TSE and 2D-DIR-TSE in LA (0.95) and WA (0.95). In aneurysmal regions, 95% limits of agreement were LA, WA, and NWI of -29.9–30.4 mm2, -18.8–15.0 mm2, and -0.22–0.20, respectively. In normal regions, the 95% limits of agreement were LA, WA, and NWI of -4.44–4.38 mm2, -3.51–4.30 mm2, and -0.14–0.16, respectively. No fixed and proportional biases between 3D-TSE and 2D-DIR-TSE images in aneurysmal and normal regions were noted.Conclusions: 3D-TSE was reproducible with conventional 2D-DIR-TSE for coronary vessel wall assessment on KD.


2019 ◽  
Vol 62 ◽  
pp. 159-166 ◽  
Author(s):  
Koji Matsumoto ◽  
Hajime Yokota ◽  
Hiroki Mukai ◽  
Ryota Ebata ◽  
Naoki Saito ◽  
...  