Experimental study of the retention properties of a cyclo olefin polymer pillar array column in reversed-phase mode

2010 ◽  
Vol 33 (21) ◽  
pp. 3313-3318 ◽  
Author(s):  
Xavi Illa ◽  
Wim De Malsche ◽  
Han Gardeniers ◽  
Gert Desmet ◽  
Albert Romano-Rodríguez
2019 ◽  
Vol 1603 ◽  
pp. 426-432 ◽  
Author(s):  
Gábor Tóth ◽  
Tanja Panić-Janković ◽  
Goran Mitulović

2021 ◽  
Author(s):  
Karel Stejskal ◽  
Jeff Op de Beeck ◽  
Manuel Matzinger ◽  
Gerhard Duernberger ◽  
Oleksandr Boychenko ◽  
...  

In the field of LC-MS based proteomics, increases in sampling depth and proteome coverage have mainly been accomplished by rapid advances in mass spectrometer technology. The comprehensiveness and quality of data that can be generated do however also depend on the performance provided by nano liquid chromatography (nanoLC) separations. Proper selection of reversed-phase separation columns can be of paramount importance to provide the MS instrument with peptides at the highest possible concentration and separated at the highest possible resolution. As an alternative to traditional packed bed LC column technology that uses beads packed into capillary tubing, we present a novel LC column format based on photolithographic definition and Deep Reactive Ion Etching (DRIE) into silicon wafers. With a next generation pillar array column designed for universal use in bottom-up proteomics, the critical dimensions of the stationary phase support structures have been reduced by a factor of 2 to provide further increases in separation power. To demonstrate the potential for single-shot proteomics workflows, we report on a series of optimization and benchmarking experiments where we combine LC separation on a new generation of pillar array columns using Vanquish Neo UHPLC with fast Orbitrap Tribrid MS data-dependent acquisition (DDA) and High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS). In addition to providing superior proteome coverage, robust operation over more than 1 month with a single nanoESI emitter and reduction of the column related sample carry over are additional figures of merit that can help improve proteome research sensitivity, productivity and standardization.


Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


1962 ◽  
Vol 5 (4) ◽  
pp. 387-394 ◽  
Author(s):  
Bruce Quarrington ◽  
Jerome Conway ◽  
Nathan Siegel
Keyword(s):  

1974 ◽  
Vol 126 (2) ◽  
pp. 243-248
Author(s):  
A WAKABAYASHI ◽  
T KUBO ◽  
K CHARNEY ◽  
Y NAKAMURA ◽  
J CONNOLLY

1963 ◽  
Vol 45 (3) ◽  
pp. 374-383 ◽  
Author(s):  
Donald C. McIlrath ◽  
George A. Hallenbeck ◽  
Hubert A. Allen ◽  
Charles V. Mann ◽  
Edward J. Baldes ◽  
...  
Keyword(s):  

1958 ◽  
Vol 34 (1) ◽  
pp. 11-20 ◽  
Author(s):  
Henry D. Janowitz ◽  
Vernon A. Weinstein ◽  
Rhoda G. Shaer ◽  
James F. Cereghini ◽  
Franklin Hollander

Sign in / Sign up

Export Citation Format

Share Document