Development and validation of an analytical method for quantitative determination of three potentially genotoxic impurities in vildagliptin drug material using HPLC ‐MS

Author(s):  
Bashar Al‐Sabti ◽  
Jehad Harbali
Author(s):  
A.C. Bhosale ◽  
V.C. Bhagat ◽  
V. V Kunjir ◽  
D.P. Kardile ◽  
R.V. Shete

Purpose: Analytical method development and validation for the quantitative determination of Prucalopride succinate in bulk and tablet formulation which plays major role in the development and manufacture of pharmaceuticals. Methods: In the present work a simple, rapid and reproducible UV-Visible Spectrophotometric method was developed and validated according to ICH guidelines. Results and Conclusions: The parameters linearity, specificity, precision, accuracy, and robustness were studied. The wavelength 243nm was selected for the estimation of drug using methanol as a solvent. The drug obeys Beer-lambert’s law over the concentration range 2-10μg/ml. The accuracy of the method was assessed by recovery studies and was found between 97.2- 98.3 %. The method was successfully applied for routine analysis of Prucalopride succinate in bulk and formulation.


2013 ◽  
Vol 96 (3) ◽  
pp. 670-675 ◽  
Author(s):  
Balwinder Singh ◽  
Kousik Mandal ◽  
Sanjay K Sahoo ◽  
Urvashi Bhardwaj ◽  
Raminderjit Singh Battu

Abstract An easy and simple analytical method was standardized and validated for the estimation of residues of spirotetramat and its metabolite spirotetramat cis enol in various substrates: okra fruits, brinjal leaves and fruits, green chili, red chili, and soil. The samples were extracted with acetonitrile, diluted with brine solution, partitioned into dichloromethane, dried over anhydrous sodium sulfate, and cleaned up by treatment with activated charcoal powder. Final clear extracts were concentrated under vacuum and reconstituted with HPLC grade acetonitrile. Residues were estimated using HPLC with a photodiode array detector and a C18 column, and confirmed by HPTLC. Acetonitrile was used as the mobile phase at 0.4 mL/min. Both spirotetramat and spirotetramat cis enol presented distinct peak at retention times of 8.518 and 7.598 min, respectively. Consistent recoveries ranging from 82 to 97% for spirotetramat and spirotetramat cis enol were observed when samples were spiked at 1.00 to 0.03 mg/kg levels. The LOQ of the method was found to be 0.03 mg/kg. The analytical method was validated in terms of parameters, including selectivity, linearity, precision, and accuracy.


Sign in / Sign up

Export Citation Format

Share Document