Surgeon radiation exposure in cone beam computed tomography-based, image-guided spinal surgery

2011 ◽  
Vol 8 (2) ◽  
pp. 196-200 ◽  
Author(s):  
Eric W. Nottmeier ◽  
Cammi Bowman ◽  
Kevin L. Nelson
2013 ◽  
Vol 19 (2) ◽  
pp. 226-231 ◽  
Author(s):  
Eric W. Nottmeier ◽  
Stephen M. Pirris ◽  
Steven Edwards ◽  
Sherri Kimes ◽  
Cammi Bowman ◽  
...  

Object Surgeon and operating room (OR) staff radiation exposure during spinal surgery is a concern, especially with the increasing use of multiplanar fluoroscopy in minimally invasive spinal surgery procedures. Cone beam computed tomography (cbCT)–based, 3D image guidance does not involve the use of active fluoroscopy during instrumentation placement and therefore decreases radiation exposure for the surgeon and OR staff during spinal fusion procedures. However, the radiation scatter of a cbCT device can be similar to that of a standard 64-slice CT scanner and thus could expose the surgeon and OR staff to radiation during image acquisition. The purpose of the present study was to measure radiation exposure at several unshielded locations in the OR when using cbCT in conjunction with 3D image-guided spinal surgery in 25 spinal surgery cases. Methods Five unshielded badge dosimeters were placed at set locations in the OR during 25 spinal surgery cases in which cbCT-based, 3D image guidance was used. The cbCT device (O-ARM) was used in conjunction with the Stealth S7 image-guided platform. The radiology department analyzed the badge dosimeters after completion of the last case. Results Fifty high-definition O-ARM spins were performed in 25 patients for spinal registration and to check instrumentation placement. Image-guided placement of 124 screws from C-2 to the ileum was accomplished without complication. Badge dosimetry analysis revealed minimal radiation exposure for the badges 6 feet from the gantry in the area of the anesthesiology equipment, as well as for the badges located 10–13 feet from the gantry on each side of the room (mean 0.7–3.6 mrem/spin). The greatest radiation exposure occurred on the badge attached to the OR table within the gantry (mean 176.9 mrem/spin), as well as on the control panel adjacent to the gantry (mean 128.0 mrem/spin). Conclusions Radiation scatter from the O-ARM was minimal at various distances outside of and not adjacent to the gantry. Although the average radiation exposure at these locations was low, an earlier study, undertaken in a similar fashion, revealed no radiation exposure when the surgeon stood behind a lead shield. This simple precaution can eliminate the small amount of radiation exposure to OR staff in cases in which the O-ARM is used.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Kyungmin Lee ◽  
Gyu-Hyoung Lee

Abstract Background Radiographs are integral in evaluating implant space and inter-root distance. The purpose of this report is to introduce a method for evaluating the 3D root position with minimal radiation using a 3D tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Materials and methods Intraoral scan and CBCT scan of the patient were obtained before treatment. In the CBCT image, tooth segmentation was performed by isolating individual teeth from the maxillary and mandibular alveolar bone using software program. The 3D tooth model was fabricated by combining segmented individual teeth with the intraoral scan. Results A post-treatment intraoral scan was integrated into the tooth model, and the resulting position of the root could be predicted without additional radiographs. It is possible to monitor the root position after a pretreatment CBCT scan using a 3D tooth model without additional radiographs. Conclusion The application of the 3D tooth model benefits the patient by reducing repeated radiation exposure while providing the clinician with a precise treatment evaluation to monitor tooth movement.


2011 ◽  
Vol 54 (3) ◽  
pp. 215-223 ◽  
Author(s):  
Simon C. Leschka ◽  
Drazenko Babic ◽  
Samer El Shikh ◽  
Christine Wossmann ◽  
Martin Schumacher ◽  
...  

2016 ◽  
Vol 7 (2) ◽  
pp. 74-77 ◽  
Author(s):  
Zaid Baqain ◽  
Abeer Al Hadidi

Dental cone beam computed tomography (CBCT) is the three-dimensional imaging of choice in modern dentistry. In the developed world, guidelines have been published on the use of CBCT in dentistry, largely in response to the risks associated with ionising radiation exposure. However, the availability of different models on the market at affordable prices has made this machine an integral part of the contemporary dentists’ apparatus, even in the developing world. Here, we underline the importance of awareness on radiation protection, image acquisition, familiarity with the software and image interpretation.