Examination of the Optimal Frequency of the Cyclic Load in the Inverse Analyses of the Heat Conduction of Infrared Thermography

Author(s):  
Kenji Machida ◽  
Shohei Miyagawa ◽  
Koich Hayafune
2006 ◽  
Vol 326-328 ◽  
pp. 1137-1140 ◽  
Author(s):  
Kenji Machida ◽  
Shohei Miyagawa

Influence of the frequency to the temperature image obtained by an infrared thermography was investigated using specimens of three kinds of materials at four kinds of frequencies of the cyclic load. Then, the infrared hybrid method was developed to separate individual stress components. However, the influence of heat conduction is inevitable in the infrared stress measurement method. Therefore, an error arises in the infrared hybrid analysis. Then, the system which corrects the error by the inverse analysis was developed. Thereby, the accuracy of the stress intensity factor was able to be raised. Furthermore, the accuracy of hybrid method considering to heat conduction was discussed in comparison with the 3-D finite element analysis and 2-D hybrid method.


2012 ◽  
Vol 249-250 ◽  
pp. 46-50 ◽  
Author(s):  
Fu Zhou Feng ◽  
Chao Sheng Zhang ◽  
Qing Xu Min ◽  
Peng Cheng Jiang

Ultrasonic infrared thermography is a novel nondestructive detection technique, which combines a short ultrasonic pulse excitation and infrared imaging to detect defects, such as crack, in materials and structures. A simplified one-dimension heat-conduction model excited by ultrasonic pulses is put forward in this paper. Based on this model, a serial of image processing methods for recognition and reconstruction of cracks were presented. Results obtained show that the proposed method is creditable and applicable.


2007 ◽  
Vol 353-358 ◽  
pp. 3092-3095
Author(s):  
Kenji Machida ◽  
Shohei Miyagawa

Recently, the influence of heat conduction has been considered to be a big problem. Then, the influence of heat conduction was investigated by the experiment which changed the material, thickness of the specimen and frequency of a cyclic load. Then, the infrared hybrid method was developed to separate individual stress components. However, it has the influence by heat conduction in the infrared stress measuring method. Therefore, an error will arise in the infrared hybrid analysis. Then, the system which corrects the error by the inverse analysis was developed. Thereby, the accuracy of the stress intensity factor was able to be raised. Furthermore, the accuracy of hybrid method considering to heat conduction was discussed in comparison with the 3-D finite-element analysis and 2-D hybrid method.