New Improved Method of Setting the Jaw’s Coordinate System

Author(s):  
Srdjan Živković ◽  
Nemanja Majstorović ◽  
Branislav Glišić ◽  
Davorin Kramar
1975 ◽  
Vol 26 ◽  
pp. 87-92
Author(s):  
P. L. Bender

AbstractFive important geodynamical quantities which are closely linked are: 1) motions of points on the Earth’s surface; 2)polar motion; 3) changes in UT1-UTC; 4) nutation; and 5) motion of the geocenter. For each of these we expect to achieve measurements in the near future which have an accuracy of 1 to 3 cm or 0.3 to 1 milliarcsec.From a metrological point of view, one can say simply: “Measure each quantity against whichever coordinate system you can make the most accurate measurements with respect to”. I believe that this statement should serve as a guiding principle for the recommendations of the colloquium. However, it also is important that the coordinate systems help to provide a clear separation between the different phenomena of interest, and correspond closely to the conceptual definitions in terms of which geophysicists think about the phenomena.In any discussion of angular motion in space, both a “body-fixed” system and a “space-fixed” system are used. Some relevant types of coordinate systems, reference directions, or reference points which have been considered are: 1) celestial systems based on optical star catalogs, distant galaxies, radio source catalogs, or the Moon and inner planets; 2) the Earth’s axis of rotation, which defines a line through the Earth as well as a celestial reference direction; 3) the geocenter; and 4) “quasi-Earth-fixed” coordinate systems.When a geophysicists discusses UT1 and polar motion, he usually is thinking of the angular motion of the main part of the mantle with respect to an inertial frame and to the direction of the spin axis. Since the velocities of relative motion in most of the mantle are expectd to be extremely small, even if “substantial” deep convection is occurring, the conceptual “quasi-Earth-fixed” reference frame seems well defined. Methods for realizing a close approximation to this frame fortunately exist. Hopefully, this colloquium will recommend procedures for establishing and maintaining such a system for use in geodynamics. Motion of points on the Earth’s surface and of the geocenter can be measured against such a system with the full accuracy of the new techniques.The situation with respect to celestial reference frames is different. The various measurement techniques give changes in the orientation of the Earth, relative to different systems, so that we would like to know the relative motions of the systems in order to compare the results. However, there does not appear to be a need for defining any new system. Subjective figures of merit for the various system dependon both the accuracy with which measurements can be made against them and the degree to which they can be related to inertial systems.The main coordinate system requirement related to the 5 geodynamic quantities discussed in this talk is thus for the establishment and maintenance of a “quasi-Earth-fixed” coordinate system which closely approximates the motion of the main part of the mantle. Changes in the orientation of this system with respect to the various celestial systems can be determined by both the new and the conventional techniques, provided that some knowledge of changes in the local vertical is available. Changes in the axis of rotation and in the geocenter with respect to this system also can be obtained, as well as measurements of nutation.


1975 ◽  
Vol 26 ◽  
pp. 21-26

An ideal definition of a reference coordinate system should meet the following general requirements:1. It should be as conceptually simple as possible, so its philosophy is well understood by the users.2. It should imply as few physical assumptions as possible. Wherever they are necessary, such assumptions should be of a very general character and, in particular, they should not be dependent upon astronomical and geophysical detailed theories.3. It should suggest a materialization that is dynamically stable and is accessible to observations with the required accuracy.


Author(s):  
E.A. Fischione ◽  
P.E. Fischione ◽  
J.J. Haugh ◽  
M.G. Burke

A common requirement for both Atom Probe Field-Ion Microscopy (APFIM) and Scanning Tunnelling Microscopy (STM) is a sharp pointed tip for use as either the specimen (APFIM) or the probe (STM). Traditionally, tips have been prepared by either chemical or electropolishing techniques. Recently, ion-milling has been successfully employed in the production of APFIM tips [1]. Conventional electropolishing techniques are applicable to a wide variety of metals, but generally require careful manual adjustments during the polishing process and may also be time-consuming. In order to reduce the time and effort involved in the preparation process, a compact, self-contained polishing unit has been developed. This system is based upon the conventional two-stage electropolishing technique in which the specimen/tip blank is first locally thinned or “necked”, and subsequently electropolished until separation occurs.[2,3] The result of this process is the production of two APFIM or STM tips. A mechanized polishing unit that provides these functions while automatically maintaining alignment has been designed and developed.


Author(s):  
J. C. Fanning ◽  
J. F. White ◽  
R. Polewski ◽  
E. G. Cleary

Elastic tissue is an important component of the walls of arteries and veins, of skin, of the lungs and in lesser amounts, of many other tissues. It is responsible for the rubber-like properties of the arteries and for the normal texture of young skin. It undergoes changes in a number of important diseases such as atherosclerosis and emphysema and on exposure of skin to sunlight.We have recently described methods for the localizationof elastic tissue components in normal animal and human tissues. In the study of developing and diseased tissues it is often not possible to obtain samples which have been optimally prepared for immuno-electron microscopy. Sometimes there is also a need to examine retrospectively samples collected some years previously. We have therefore developed modifications to our published methods to allow examination of human and animal tissue samples obtained at surgery or during post mortem which have subsequently been: 1. stored frozen at -35° or -70°C for biochemical examination; 2.


1895 ◽  
Vol 39 (1003supp) ◽  
pp. 16026-16027
Author(s):  
John Vansant
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document