A Secure and Moderate Data Synchronization Method Based on Network Isolation

Author(s):  
Bing Zhang ◽  
Zhiyong Guo ◽  
Yangdan Ni ◽  
Meng Yang ◽  
Ruiying Cheng ◽  
...  
2014 ◽  
Vol 1070-1072 ◽  
pp. 1413-1417
Author(s):  
Tong Yin Liu ◽  
Liang Gao ◽  
Yong Dong Zhang

Data synchronization of electronic instrument transformer is introduced. Synchronization method commonly used are analyzed in aspects of their advantages and disadvantages, such as interpolation synchronization, impulsive synchronization method; Then, a new approach based on Newton interpolation is presented, and the simulation and error analysis are given. The theoretical analysis results show that this method can reach to the same precision with Lagrange interpolation which is accurate in synchronization of harmonic components and obtain the synchronized data fast. Finally this paper sets equal interval sampling and non-equal interval sampling data, and then calculates maximum error in the case of the steady state and transient state respectively by using Matlab. The simulation results proved the feasibility of this method and its engineering practical value.


2020 ◽  
Vol 10 (11) ◽  
pp. 3768
Author(s):  
Ruyun Tian ◽  
Junjie Zhang ◽  
Shuai Zhang ◽  
Longxu Wang ◽  
Hongyuan Yang ◽  
...  

Large numbers of seismic channels and high-density energy-efficient acquisition systems are the development trend of seismic instruments and have attracted high R&D interests in recent years. The combination of remote sensing and wireless sensor network technology provides superior observation capabilities for high-density seismic exploration. However, large-scale and multi-node acquisition methods place higher requirements on time synchronization performance. Seismic data with poor time synchronization will cause considerable errors in the interpretation of seismic data and even have no practical significance. Thus, the strict time synchronization performance is the prerequisite and basis for the application of cable-less storage seismograph in high-density seismic array applications. The existing time synchronization methods have high power consumption and poor time synchronization accuracy, which is not suitable for the long-time task. In addition, these methods are affected by the number of nodes and the distance. This paper presents an energy-efficient time-sharing indexed interpolation intercept method for the seismic data synchronization. The time synchronization method uses the high-precision TCXO as the main clock and records GPS time in the SD card at intervals to achieve the high-precision time-stamp for the seismic data. Then the seismic data is intercepted intermittently based on precise time stamps, which achieves the strict seismic data synchronization. Performance analysis shows that the time synchronization accuracy of the proposed method is 0.6 μs and saves 73% energy of the time-sync periods compared to the common GPS timing method. The field measurement results indicate that the time synchronization accuracy is not associated with the working time and the distance between nodes so that the proposed synchronization method is suitable for the high-density seismic survey.


Sign in / Sign up

Export Citation Format

Share Document