Effect of Thermal Aging on SCC, Material Properties and Fracture Toughness of Stainless Steel Weld Metals

Author(s):  
T. Lucas ◽  
R. G. Ballinger ◽  
H. Hanninen ◽  
T. Saukkonen
CORROSION ◽  
10.5006/2902 ◽  
2019 ◽  
Vol 75 (4) ◽  
pp. 377-388 ◽  
Author(s):  
Xiaodong Lin ◽  
Qunjia Peng ◽  
En-Hou Han ◽  
Wei Ke

Double loop electrochemical potentiokinetic reactivation (DL-EPR) was applied to evaluate thermal aging of 308L stainless steel weld metal. It was found that the activation and reactivation peaks of DL-EPR curve were induced by dissolution of austenite and δ-ferrite, respectively. Before saturation of hardness, the linear relationship between reactivation ratio and hardness could be used for assessing the thermal aging-induced hardening. In the following thermal aging process, the reactivation ratio is applicable to assess the occurrence of the saturation of thermal aging-induced hardening. The results demonstrated that the DL-EPR test is applicable to assess the evolution of thermal aging.