Solar Power Plant Performance

Author(s):  
Jesús Polo
2021 ◽  
Vol 11 (20) ◽  
pp. 9576
Author(s):  
Wisam Abed Kattea Al-Maliki ◽  
Adnan G. Tuaamah Al-Hasnawi ◽  
Hasanain A. Abdul Wahhab ◽  
Falah Alobaid ◽  
Bernd Epple

The present work focuses on the development of a detailed dynamic model of an existing parabolic trough solar power plant (PTSPP) in Spain. This work is the first attempt to analyse the dynamic interaction of all parts, including solar field (SF), thermal storage system (TSS) and power block (PB), and describes the heat transfer fluid (HTF) and steam/water paths in detail. Advanced control circuits, including drum level, economiser water bypass, attemperator and steam bypass controllers, are also included. The parabolic trough power plant is modelled using Advanced Process Simulation Software (APROS). An accurate description of control structures and operation strategy is necessary in order to achieve a reasonable dynamic response. This model would help to identify the best operation strategy due to DNI (direct normal irradiation) variations during the daytime. The operation strategy used in this model has also been shown to be effective compared to decisions made by operators on cloudy periods by improving power plant performance and increasing operating hours.


Author(s):  
J. Raja ◽  
Nishant Jain ◽  
C. Christober Asir Rajan

<p>in India to meet its future energy demand. This paper emphasis on the performance assessment of grid connected mega-watt solar power plant which is of 23MW and 5MW are located in different geographical location in India. Performance assessment is the finest way to determine the potential of energy generation in solar power plant and it also helps in evaluating the design, operation and maintenance of existing and future solar power plant. The parameters namely calculation of annual energy generated, reference yield, final yield, system losses, cell temperature losses, performance ratio and capacity utilization factor are considered in examining solar power plant performance. In this study experimental measurement of two solar power plant one is located in Gujarat (23MW) and another in Andhra Pradesh (5MW) are compared with the results of estimated model from METEONORM 7.1 and PVSYST V6.67 software tools. Experimental measurement at solar power plant location covers the following measurement for analysis like actual weather condition, daily/hourly irradiance, actual energy yield and compares with capacity utilization factor, performance ratio and temperature corrected performance ratio parameters. The results demonstrated in this paper show the gap between the actual performance of solar power plant and the estimated model from software tool. Performance of solar power plant is satisfactory in comparison with other literature reviews. The actual annual energy generated for 23MW solar power plant was 37991MWh, 18.83% capacity utilization factor, 73.87% performance ratio and 75.33% temperature corrected performance ratio. Similarly, the actual annual energy generated for 5MW solar power plant was 9047.7MWh, 18.41% capacity utilization factor, 80.31% performance ratio and 79.90% temperature corrected performance ratio.</p>


2018 ◽  
Author(s):  
P. K. Verma ◽  
A. K. Vishnoi ◽  
Naveen Kumar ◽  
Arun K. Nayak ◽  
G. J. Gorade ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document