A Tissue-Equivalent Radioluminescent Fiberoptic Probe for In-Vivo Dosimetry Based on Mn-Doped Lithium Tetraborate

Author(s):  
M. Santiago ◽  
M. Prokic ◽  
P. Molina ◽  
J. Marcazzó ◽  
E. Caselli
2012 ◽  
Vol 30 (27_suppl) ◽  
pp. 157-157
Author(s):  
Erin Healy ◽  
Shawnee Anderson ◽  
Jing Cui ◽  
Laurel Beckett ◽  
Allen M. Chen ◽  
...  

157 Background: The use of brass mesh as an alternative to a bolus is relatively uncommon in post-mastectomy chest wall radiation therapy (PMRT). This study aimed to characterize the skin dose effects of using 2mm fine brass mesh as an alternative to the traditional tissue-equivalent bolus during chest wall PMRT. Methods: Data was collected from patients who received PMRT using brass mesh at UC Davis Medical Center’s Department of Radiation Oncology between January 2008 and June 2011. Several patient characteristics including age, body habitus, and ethnicity were analyzed along with several disease and treatment characteristics to determine whether or not they had an impact on the skin reaction observed during radiation treatment. In addition to assessing skin toxicity visually using standardized National Cancer Institute scores (NCIS), surface doses were measured for 16 of the 48 patients (33%) to quantify radiation exposure to the chest wall. Results: 48 female patients aged 28-83 received PMRT using brass mesh. As expected, the severity of skin toxicity increased with subsequent doses of radiation with all patients beginning treatment with no skin reaction (NCIS = 0) and the majority of patients completing treatment with either faint to moderate erythema (N = 19, 40%, NCIS = 1) or moderate to brisk erythema (N = 23, 48%, NCIS = 2). In vivo dosimetry analysis revealed surface doses between 81% and 110% of the prescribed dose, with an average of 99% of the prescribed radiation dose being delivered and a standard deviation of 10%. Conclusions: For post-mastectomy chest wall radiation therapy, brass mesh is an effective alternative to the tissue-equivalent bolus. The brass mesh achieved moderate erythema in the majority of patients at the end of treatment and the surface dose was validated using in vivo dosimetry.


2020 ◽  
Author(s):  
Terufumi Kawamoto ◽  
Naoto Shikama ◽  
Chie Kurokawa ◽  
Naoya Hara ◽  
Masaki Oshima ◽  
...  

Abstract BackgroundThere remains wide variation in the use of chest wall boluses for postmastectomy radiotherapy (PMRT). Therefore, we aimed to prospectively evaluate the use of a 1-mm-thick daily tissue-equivalent bolus in patients who received PMRT using thermoluminescent dosimeters (TLDs) and skin toxicity assessment.Materials and MethodsWe collected data from patients with a 1-mm-thick daily bolus during PMRT at The Juntendo University Hospital. The surface dose was measured in vivo under the 1-mm-thick bolus on the chest wall. We assessed the acute skin toxicity weekly during PMRT, and 1, 2, 4, and 12 weeks after the completion of PMRT.ResultsA total of 19 patients aged 32 − 79 years old received PMRT from July 2019 to January 2020. All patients completed the protocol treatment without interruptions, and the median follow-up was 32 weeks. In vivo dosimetry analysis revealed surface doses between 77% and 113% of the prescribed dose, with a mean of 92% of the prescribed radiation dose, and a standard deviation of 7% being delivered. Grade 2 dermatitis was found in 10 patients (53%), and Grade 3 dermatitis was found in one patient (5%). All cases of Grade 2 and 3 dermatitis were improved 4 weeks after PMRT. There were no cases of Grade 4 dermatitis and no chest wall recurrences during the treatment or follow-up period.ConclusionsThe 1-mm-thick daily bolus is a feasible regimen for PMRT, with appropriate dose buildup and acceptable skin toxicity without treatment interruptions.Trial registrationThe University Hospital Medical Information Network Clinical Trials Registry, UMIN000035773. Registered 1 July 2019, https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000040622


1972 ◽  
Vol 101 (1) ◽  
pp. 51-54 ◽  
Author(s):  
G. Jacob ◽  
G. Forcinal ◽  
J. Meuleman

10.37206/88 ◽  
2005 ◽  
Author(s):  
Ellen Yorke ◽  
Rodica Alecu ◽  
Li Ding ◽  
Doracy Fontenla ◽  
Andre Kalend ◽  
...  

Author(s):  
F. Fiedler ◽  
U. Dersch ◽  
C. Golnik ◽  
T. Kormoll ◽  
A. Muller ◽  
...  
Keyword(s):  

2004 ◽  
Vol 51 (6) ◽  
pp. 3013-3018 ◽  
Author(s):  
A.B. Rosenfeld ◽  
D.L. Cutajar ◽  
M.L.F. Lerch ◽  
G.J. Takacs ◽  
J. Brady ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
E Di Girolamo ◽  
M Appignani ◽  
N Furia ◽  
M Marini ◽  
P De Filippo ◽  
...  

Abstract Background Direct exposure of implantable cardioverter-defibrillators (ICDs) during radiotherapy is still considered potentially harmful, or even unsafe, by manufacturers and current recommendations. The effects of photon beams on ICDs are unpredictable, depending on multiple factors, and malfunctions may present during exposure. Purpose To evaluate transient ICD malfunctions by direct exposure to doses up to 10 Gy during low-energy RT, forty-three contemporary wireless-enabled ICDs, with at least 4 months to elective replacement indicator (ERI) were evaluated in a real-time in-vitro session in three different centres. Methods All ICDs had baseline interrogation. Single chamber devices were programmed to the VVI/40 mode and dual or triple chamber devices were programmed to the DDD/40 mode. Rate response function and antitachycardia therapies were disabled, with the ventricular tachycardia (VT)/ventricular fibrillation (VF) detection windows still active. A centring computed tomography was performed to build the corresponding treatment plan and the ICDs were blinded randomized to receive either 2-, 5- or 10-Gy exposure by a low photon-energy linear accelerator (6MV) in a homemade water phantom (600 MU/min). The effective dose received by the ICDs was randomly assessed by an in-vivo dosimetry. During radiotherapy, the ICDs were observed in a real-time session using manufacturer specific programmer, and device function (pacing, sensing, programmed parameters, arrhythmia detections) was recorder by the video camera in the bunker throughout the entire photon exposure. All ICDs had an interrogation session immediately after exposure. Results During radiotherapy course, almost all ICDs (93%) recorded major or minor transient electromagnetic interferences. On detail, sixteen ICDs (37.2%) reported atrial and/or ventricular oversensing, with base-rate-pacing inhibition and VT/VF detection. Twenty-four ICDs (55.8%) recorded non clinically relevant noise, and no detections were observed. Only three ICDs (7%) reported neither transient malfunction nor minor noise, withstanding direct radiation exposure. At immediate post-exposure interrogation, the ICDs that recorded major real-time malfunctions had VT/VF detections stored in the device memory. In none of the ICDs spontaneous changes in parameter settings were reported. Malfunctions occurred regardless of either 2-, 5- or 10-Gy photon beam exposure. Conclusions Transient electromagnetic interferences were observed in most of the contemporary ICDs during radiotherapy course, regardless of photon dose. To avoid potentially life-threatening ICD malfunctions such as pacing inhibition or inappropriate shock delivery, magnet application on the pocket site or ICD reprogramming to the asynchronous mode are still suggested in ICD patients ongoing even low energy radiotherapy exposure. Funding Acknowledgement Type of funding source: None


2009 ◽  
Vol 13 (3) ◽  
pp. 182-189 ◽  
Author(s):  
A. Ismail ◽  
J.-Y. Giraud ◽  
G.N. Lu ◽  
R. Sihanath ◽  
P. Pittet ◽  
...  