On Creep Laboratory Tests in Soil Mechanics

Author(s):  
Arman Khoshghalb
2013 ◽  
Vol 419 ◽  
pp. 853-857
Author(s):  
Zhen Ying Zhang ◽  
Da Zhi Wu ◽  
Cha Wang

To investigate the compressibility of the silt, three soil samples are collected from Xiasha zone, Hangzhou, Zhejiang Province, China. The geotechnical engineering parameters of the silt soil are measured in the soil mechanics laboratory. Tests results show that the uniformity coefficient of the silt is 13.6, the natural density is 1.96t/m3, the moisture content is 17.0%, the plasticity index is 9.4, the compression coefficient varies from 0.06 to 0.40MPa-1, and the compression index varies from 0.015 to 0.108. Finally, the properties of the compression are studied, and find that the compressibility of the silt soil is very large, and the relationship between the initial void ratio and the logarithm pressure is linear.


VASA ◽  
2001 ◽  
Vol 30 (Supplement 58) ◽  
pp. 21-27
Author(s):  
Luther

In diabetic foot disease, critical limb ischaemia (CLI) cannot be precisely described using established definitions. For clinical use, the Fontaine classification complemented with any objective verification of a reduced arterial circulation is sufficient for decision making. For scientific purposes, objective measurement criteria should be reported. Assessment of CLI should rely on the physical examination of the limb arteries, complemented by laboratory tests like the shape of the PVR curve at ankle or toe levels, and arteriography. The prognosis of CLI in diabetic foot disease depends on the success of arterial reconstruction. The best prognosis for the patients is with a preserved limb. Reconstructive surgery is the best choice for the majority of patients.


2012 ◽  
Vol 17 (1) ◽  
pp. 1-10 ◽  
Author(s):  
Rosalind Potts ◽  
Robin Law ◽  
John F. Golding ◽  
David Groome

Retrieval-induced forgetting (RIF) refers to the finding that the retrieval of an item from memory impairs the retrieval of related items. The extent to which this impairment is found in laboratory tests varies between individuals, and recent studies have reported an association between individual differences in the strength of the RIF effect and other cognitive and clinical factors. The present study investigated the reliability of these individual differences in the RIF effect. A RIF task was administered to the same individuals on two occasions (sessions T1 and T2), one week apart. For Experiments 1 and 2 the final retrieval test at each session made use of a category-cue procedure, whereas Experiment 3 employed category-plus-letter cues, and Experiment 4 used a recognition test. In Experiment 2 the same test items that were studied, practiced, and tested at T1 were also studied, practiced, and tested at T2, but for the remaining three experiments two different item sets were used at T1 and T2. A significant RIF effect was found in all four experiments. A significant correlation was found between RIF scores at T1 and T2 in Experiment 2, but for the other three experiments the correlations between RIF scores at T1 and T2 failed to reach significance. This study therefore failed to find clear evidence for reliable individual differences in RIF performance, except where the same test materials were used for both test sessions. These findings have important implications for studies involving individual differences in RIF performance.


1974 ◽  
Vol 32 (02/03) ◽  
pp. 483-491
Author(s):  
E. A Loeliger ◽  
M. J Boekhout-Mussert ◽  
L. P van Halem-Visser ◽  
J. D. E Habbema ◽  
H de Jonge

SummaryThe present study concerned the reproducibility of the so-called prothrombin time as assessed with a series of more commonly used modifications of the Quick’s onestage assay procedure, i.e. the British comparative reagent, homemade human brain thromboplastin, Simplastin, Simplastin A, and Thrombotest. All five procedures were tested manually on pooled lyophilized normal and patients’ plasmas. In addition, Simplastin A and Thrombotest were investigated semiautomatically on individual freshly prepared patients’ plasmas. From the results obtained, the following conclusions may be drawn :The reproducibility of results obtained with manual reading on lyophilized plasmas is satisfactory for all five test procedures. For Simplastin, the reproducibility of values in the range of insufficient anticoagulation is relatively low due to the low discrimination power of the test procedure in the near-normal range (so-called low sensitivity of rabbit brain thromboplastins). The reproducibility of Thrombotest excels as a consequence of its particularly easily discerned coagulation endpoint.The reproducibility of Thrombotest, when tested on freshly prepared plasmas using Schnitger’s semiautomatic coagulometer (a fibrinometer-liJce apparatus), is no longer superior to that of Simplastin A.The constant of proportionality between the coagulation times formed with Simplastin A and Thrombotest was estimated at 0.64.Reconstituted Thrombotest is stable for 24 hours when stored at 4° C, whereas reconstituted Simplastin A is not.The Simplastin A method and Thrombotest seem to be equally sensitive to “activation” of blood coagulation upon storage.


1964 ◽  
Vol 11 (02) ◽  
pp. 506-512 ◽  
Author(s):  
V. A Lovric ◽  
J Margolis

SummaryAn adaptation of “kaolin clotting time” and prothrombin time for use on haemolysed capillary blood provided simple and sensitive screening tests suitable for use in infants and children. A survey of three year’s experience shows that these are reliable routine laboratory tests for detection of latent coagulation disorders.


1981 ◽  
Vol 46 (04) ◽  
pp. 752-756 ◽  
Author(s):  
L Zuckerman ◽  
E Cohen ◽  
J P Vagher ◽  
E Woodward ◽  
J A Caprini

SummaryThrombelastography, although proven as a useful research tool has not been evaluated for its clinical utility against common coagulation laboratory tests. In this study we compare the thrombelastographic measurements with six common tests (the hematocrit, platelet count, fibrinogen, prothrombin time, activated thromboplastin time and fibrin split products). For such comparisons, two samples of subjects were selected, 141 normal volunteers and 121 patients with cancer. The data was subjected to various statistical techniques such as correlation, ANOVA, canonical and discriminant analysis to measure the extent of the correlations between the two sets of variables and their relative strength to detect blood clotting abnormalities. The results indicate that, although there is a strong relationship between the thrombelastographic variables and these common laboratory tests, the thrombelastographic variables contain additional information on the hemostatic process.


Sign in / Sign up

Export Citation Format

Share Document