Plain Film or MDCT as a First Diagnostic Tool in Patients with Cervical Spine Injury: Critical Issues

2012 ◽  
pp. 65-77
Author(s):  
Gianluigi Guarnieri ◽  
Roberto Izzo ◽  
Mario Muto
Neurosurgery ◽  
2008 ◽  
Vol 62 (3) ◽  
pp. 700-708 ◽  
Author(s):  
Hugh J.L. Garton ◽  
Matthew R. Hammer

Abstract OBJECTIVE In evaluating the pediatric cervical spine for injury, the use of adult protocols without sufficient sensitivity to pediatric injury patterns may lead to excessive radiation doses. Data on injury location and means of detection can inform pediatric-specific guideline development. METHODS We retrospectively identified pediatric patients with codes from the International Classification of Diseases, 9th Revision, for cervical spine injury treated between 1980 and 2000. Collected data included physical findings, radiographic means of detection, and location of injury. Sensitivity of plain x-rays and diagnostic yield from additional radiographic studies were calculated. RESULTS Of 239 patients, 190 had true injuries and adequate medical records; of these, 187 had adequate radiology records. Patients without radiographic abnormality were excluded. In 34 children younger than 8 years, National Emergency X-Radiography Utilization Study criteria missed two injuries (sensitivity, 94%), with 76% of injuries occurring from occiput–C2. In 158 children older than 8 years, National Emergency X-Radiography Utilization Study criteria identified all injured patients (sensitivity, 100%), with 25% of injuries occurring from occiput–C2. For children younger than 8 years, plain-film sensitivity was 75% and combination plain-film/occiput–C3 computed tomographic scan had a sensitivity of 94%, whereas combination plain-film and flexion-extension views had 81% sensitivity. In patients older than 8 years, the sensitivities were 93%, 97%, and 94%, respectively. CONCLUSION Younger children tend to have more rostral (occiput–C2) injuries compared with older children. The National Emergency X-Radiography Utilization Study protocol may have lower sensitivity in young children than in adults. Limited computed tomography from occiput–C3 may increase diagnostic yield appreciably in young children compared with flexion-extension views. Further prospective studies, especially of young children, are needed to develop reliable pediatric protocols.


2005 ◽  
Vol 2 (2) ◽  
pp. 99-101 ◽  
Author(s):  
TVSP Murthy ◽  
Parmeet Bhatia ◽  
RL Gogna ◽  
T Prabhakar

2004 ◽  
Vol 1 (1) ◽  
pp. 43-47
Author(s):  
PK Sahoo ◽  
Prakash Singh ◽  
HS Bhatoe

1981 ◽  
Vol 30 (1) ◽  
pp. 41-47
Author(s):  
M. Yamanaka ◽  
G. Awaya ◽  
S. Takata ◽  
N. Nishijima ◽  
S. Shimamura

2014 ◽  
Vol 14 (10) ◽  
pp. 2275-2280 ◽  
Author(s):  
Hirotaka Chikuda ◽  
Junichi Ohya ◽  
Hiromasa Horiguchi ◽  
Katsushi Takeshita ◽  
Kiyohide Fushimi ◽  
...  

1997 ◽  
Vol 87 (6) ◽  
pp. 1335-1342 ◽  
Author(s):  
Andrew D. J. Watts ◽  
Adrian W. Gelb ◽  
David B. Bach ◽  
David M. Pelz

Background In the emergency trauma situation, in-line stabilization (ILS) of the cervical spine is used to reduce head and neck extension during laryngoscopy. The Bullard laryngoscope may result in less cervical spine movement than the Macintosh laryngoscope. The aim of this study was to compare cervical spine extension (measured radiographically) and time to intubation with the Bullard and Macintosh laryngoscopes during a simulated emergency with cervical spine precautions taken. Methods Twenty-nine patients requiring general anesthesia and endotracheal intubation were studied. Patients were placed on a rigid board and anesthesia was induced. Laryngoscopy was performed on four occasions: with the Bullard and Macintosh laryngoscopes both with and without manual ILS. Cricoid pressure was applied with ILS. To determine cervical spine extension, radiographs were exposed before and during laryngoscopy. Times to intubation and grade view of the larynx were also compared. Results Cervical spine extension (occiput-C5) was greatest with the Macintosh laryngoscope (25.9 degrees +/- 2.8 degrees). Extension was reduced when using the Macintosh laryngoscope with ILS (12.9 +/- 2.1 degrees) and the Bullard laryngoscope without stabilization (12.6 +/- 1.8 degrees; P < 0.05). Times to intubation were similar for the Macintosh laryngoscope with ILS (20.3 +/- 12.8 s) and for the Bullard without ILS (25.6 +/- 10.4 s). Manual ILS with the Bullard laryngoscope results in further reduction in cervical spine extension (5.6 +/- 1.5 degrees) but prolongs time to intubation (40.3 +/- 19.5 s; P < 0.05). Conclusions Cervical spine extension and time to intubation are similar for the Macintosh laryngoscope with ILS and the Bullard laryngoscope without ILS. However, time to intubation is significantly prolonged when the Bullard laryngoscope is used in a simulated emergency with cervical spine precautions taken. This suggests that the Bullard laryngoscope may be a useful adjunct to intubation of patients with potential cervical spine injury when time to intubation is not critical.


Sign in / Sign up

Export Citation Format

Share Document