Development of Optical Computed Tomography for Evaluation of the Absorbed Dose of the Dyed Gel Dosimeter

Author(s):  
Takuya Wada ◽  
Kazuya Nakayama ◽  
Akihiro Takemura ◽  
Hiroaki Yamamoto ◽  
Hironori Kojima ◽  
...  
2016 ◽  
Vol 44 ◽  
pp. 1660221
Author(s):  
Chun-Hsu Yao ◽  
Ting-Yu Tsai ◽  
Bor-Tsung Hsieh ◽  
Yuk-Wah Tsang ◽  
Chung-Yu Chiu ◽  
...  

This study aimed to investigate the dosimetric characteristics of intensity-modulated radiation therapy (IMRT) and RapidArc therapy by using 3D N-isopropylacrylamide (NIPAM) polymer gel. Optical computed tomography, specifically OCTOPUSTM-10X fast optical computed tomography scanner, was used as a readout tool. Two cylindrical acrylic phantoms (10 cm in diameter, 10 cm in height, and 3 mm in thickness) were filled with NIPAM gel and used for IMRT and RapidArc irradiation by using the Clinac iX treatment machine. The irradiation energies for IMRT and RapidArc® were set as 6 MV photons, but their irradiation angles and dose rates differed during irradiation. The irradiation angles of IMRT were 120°, 155°, 180°, 215°, and 245°, and the dose rate was fixed at 400 cGy/min. RapidArc® rotated continuously during irradiation, and the dose rate varied from 330 cGy/min to 400 cGy/min. The pass rates were 98.02% and 97.48% for IMRT and RapidArc®, respectively, and the rejected area appeared at the edge of the irradiated region. The isodose lines of IMRT and RapidArc® were consistent with those of TPS in most regions. Scattering and edge enhancement effects are main factors that cause dose inaccuracy in the edge region and reduced pass rates. Considering dose rate dependence, we used variable dose rates during irradiation with RapidArc®. Results showed that the dose distribution of NIPAM gel was consistent with that of TPS. The pass rates were also the same for IMRT and RapidArc® irradiation. This study proposes a preliminary profile of dosimetric characteristics of IMRT and RapidArc® by using a NIPAM gel dosimeter.


2021 ◽  
Author(s):  
P.L.E. Oliveira ◽  
C.R. Starling ◽  
C.L.P. Maurício ◽  
F.R. Guedes ◽  
M.A. Visconti ◽  
...  

Introduction: The objective of this study was to compare the mean absorbed dose in patients undergoing head and neck examinations using two cone beam computed tomography (CBCT, Kodak and i-CAT) and one multi-detector computed tomography (MDCT). Methods: Three thermoluminescent dosimeters (TLDs), calibrated in air kerma, were positioned in 24 regions of the head and neck of a phantom simulating an average adult. The mean absorbed dose (mGy) values in these positions, for different organs and tissues, were obtained using correction factors, considering the ratio between the mass energy absorption coefficients of organ/tissue and air. Comparison between radiation doses in the most radiosensitive regions was done by calculating the ratio of these dose values, with propagated uncertainty. Results: The dose in all regions was significantly higher for MDCT when compared to CBCT. Concerning CBCT equipment, the Kodak device had a higher absorbed dose than the i-CAT for most of the regions tested. The uncertainty of the i-CAT was greater than that of the Kodak. Conclusion: Due to the considerable difference between absorbed doses, emphasizing the higher dose values obtained in MDCT, the dissemination of CBCT application in medicine is recommended, as well as further studies to broaden the criteria for use.


2010 ◽  
Vol 250 ◽  
pp. 012046 ◽  
Author(s):  
A T Abdul Rahman ◽  
Elke Bräuer-Krisch ◽  
Thierry Brochard ◽  
John Adamovics ◽  
Steve Clowes ◽  
...  