Energy dissipation in metals in high-frequency fatigue test. II

1972 ◽  
Vol 4 (7) ◽  
pp. 856-859 ◽  
Author(s):  
V. A. Kuz'menko ◽  
A. I. Afonin
Author(s):  
Jin Wook Hwang ◽  
Dipul Chawla ◽  
Guebum Han ◽  
Melih Eriten ◽  
Corinne R. Henak

Metals ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 1415
Author(s):  
Wei Xu ◽  
Yanguang Zhao ◽  
Xin Chen ◽  
Bin Zhong ◽  
Huichen Yu ◽  
...  

This paper proposes an ultra-high frequency (UHF) fatigue test of a titanium alloy TA11 based on electrodynamic shaker in order to develop a feasible testing method in the VHCF regime. Firstly, a type of UHF fatigue specimen is designed to make its actual testing frequency reach as high as 1756 Hz. Then the influences of the loading frequency and loading types on the testing results are considered separately, and a series of comparative fatigue tests are hence conducted. The results show the testing data from the present UHF fatigue specimen agree well with those from the conventional vibration fatigue specimen with the loading frequency of 240 Hz. Furthermore, the present UHF testing data show good consistency with those from the axial-loading fatigue and rotating bending fatigue tests. But the obtained fatigue life from ultrasonic fatigue test with the loading frequency of 20 kHz is significantly higher than all other fatigue test results. Thus the proposed ultra-high frequency vibration-based fatigue test shows a balance of high efficiency and similarity with the conventional testing results.


1985 ◽  
Vol 28 (6) ◽  
pp. 442-445
Author(s):  
A. M. Donets ◽  
V. N. Fedosov ◽  
L. S. Ochneva

2019 ◽  
Vol 2019 ◽  
pp. 1-14 ◽  
Author(s):  
Xiaogang Gao ◽  
Anbin Wang ◽  
Yu He ◽  
Xiaohan Gu

In the circumstances of high-speed railways, the wheel-rail vibration is significantly aggravated by polygonal wheel wear and rail corrugation, which subsequently leads to the wheel-rail interaction at higher frequencies and potential failure of the rail fastening. In this paper, a ω-type clip of the fastening in the CRH high-speed rail was used to investigate the failure mechanism. First, a dynamic wheel-rail coupling model and a finite element analysis of the rail clip were developed, from which the rail vibration frequency and modal frequencies of the clip with different installation torques were obtained. The experimental tests and modal simulation results were mutually verified. In addition, the real-time vibration measurement and the wheel-rail wear monitoring were carried out at a CRH high-speed railway site. It was found that the resonant frequencies of the ω-type clip in the installation condition coincided with the excitation frequencies of the wheel-rail interaction induced by wheel-rail wear. The high-frequency dynamic failure mechanism of a typical ω-type clip, W300-1, is put forward for the first time. Moreover, a high-frequency rail clip fatigue test system was designed and developed specifically for this study. The loading excitation frequency of the clip test used was set as 590 Hz, and the loading amplitude was 0.05 mm. After 125-minute operation of the test system, the clip was broken at the expected location predicted by the FEA model. The high-frequency fatigue test result further verified that the failure mechanism of the ω-type clip was due to the resonance of the clip with its excitation force from the wheel-rail interaction. Finally, the clip was then structurally improved taking into account the stiffness and mass, which led to its resonant frequencies shifting away from the high-frequency excitation range, hence avoiding resonance failure of the subject clip.


2013 ◽  
Vol 8 (2) ◽  
pp. 199-205 ◽  
Author(s):  
Nastaran Tamjidi ◽  
Kohei Sato ◽  
Junpei Sakurai ◽  
Seiichi Hata

1975 ◽  
Vol 7 (8) ◽  
pp. 951-954
Author(s):  
V. A. Kuz'menko ◽  
I. A. Troyan ◽  
Ya. I. Tsimbalistyi

2011 ◽  
Vol 10 ◽  
pp. 2892-2897 ◽  
Author(s):  
C. Ghielmetti ◽  
R. Ghelichi ◽  
M. Guagliano ◽  
F. Ripamonti ◽  
S. Vezzù

2019 ◽  
Vol 25 (14) ◽  
pp. 2008-2024 ◽  
Author(s):  
X. Q. Zhou ◽  
L. Wang ◽  
D.Y. Yu ◽  
C. Y. Zhang

Wave energy can be dissipated gradually when it is propagated in viscoelastic damping material (VDM) composite structures. In this paper, after the specimens with different opening ratios (ORs) of VDM layer are prepared, the elastic wave energy propagation and dissipation characteristic of periodically perforated VDM cored sandwich structures are investigated by an experimental method. The sandwich structures are discretized into several testing points in our experiment. When the complex velocity, equivalent effective mass, and external excitation forces have been obtained at each testing point by sensors, the energy dissipation in the sandwich structure is determined based on the energy dissipation mechanism of wave transmission in solid. The experimental results are then compared with theoretical and numerical simulation results. By analyzing the computational accuracy of theoretical and numerical results using experimental data, it is shown that high consistency between theoretical, numerical, and experimental results can be achieved, especially in the medium-frequency and high-frequency ranges. Thus, our experimental results demonstrate that periodically perforated VDM sandwich structures can be applied to engineering practice for their good performance of dissipation characteristics in the middle-frequency and high-frequency ranges.


Sign in / Sign up

Export Citation Format

Share Document