scholarly journals Deformity correction and lengthening of lower legs with an external fixator

2006 ◽  
Vol 30 (6) ◽  
pp. 550-554 ◽  
Author(s):  
Hidenori Matsubara ◽  
Hiroyuki Tsuchiya ◽  
Keisuke Sakurakichi ◽  
Koji Watanabe ◽  
Katsuro Tomita
2019 ◽  
Vol 13 (2) ◽  
Author(s):  
Ying Ying Wu ◽  
Anton Plakseychuk ◽  
Kenji Shimada

Bone deformities are often complex three-dimensional (3D) deformities, and correcting them is difficult. To correct persistent clubfoot deformity in adolescents or adults, an external fixator is sometimes used to encourage tissue growth and preserve healthy tissues. However, it is difficult to set up, resulting in long surgeries and steep learning curves for surgeons. It is also bulky and obstructs patient mobility. In this paper, we introduce a new approach of defining clubfoot deformity correction as a six degrees-of-freedom (6DOF) correction, and then reducing it to just two degrees-of-freedom (2DOF) using the axis-angle representation. Therefore, only two physical trajectory joints are needed, which in turn enables a more compact fixator design. A computer planner was developed to minimize the bulk of the external fixator, and to optimize the distraction schedule to avoid overstretching the soft tissues. This reduces the learning curve for surgeons and shortens surgery time. To validate the system, a patient-specific clubfoot simulator was developed, and four experiments were performed on the clubfoot simulator. The accuracy of midfoot correction was 11 mm and 3.5 deg without loading, and 41 mm and 11.7 deg with loading. While the external fixator has to be more rigid to overcome resistance against correction, the surgical system itself was able to achieve accurate correction in less than 2 h. This is an improvement from the current method, which takes 2.5–4.5 h.


2013 ◽  
Vol 52 (3) ◽  
pp. 324-330 ◽  
Author(s):  
Munetomo Takata ◽  
Victor A. Vilensky ◽  
Hiroyuki Tsuchiya ◽  
Leonid N. Solomin

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Yanshi Liu ◽  
Kai Liu ◽  
Feiyu Cai ◽  
Tao Zhang ◽  
Aihemaitijiang Yusufu

Abstract Background It is challenging to determine the orthogonality of radiographs in daily clinical practice. The purpose of this study was to show the usefulness of an additional foot ring which might determine the orthogonality of postoperative radiographs for the parameter measurement of hexapod external fixator. Methods We retrospectively analyzed 81 consecutive trauma patients with tibial shaft fractures treated by the hexapod external fixator at our institution from September 2014 to July 2019. Starting in March 2016, the postoperative radiographs for parameter measurement were obtained under the control of an additional foot ring. The final data consisted of 47 patients in traditional radiographs (Group I) and 34 patients under the control of foot ring during the radiographic process (Group II). The demographic data, original postoperative deformities, residual deformities after final correction, number of repeated radiographs after the first postoperative radiographs, time to the satisfactory reduction achieved, and external fixation time in all patients were documented and analyzed. The Johner–Wruhs criteria were used for the final clinical outcomes evaluation at the last clinical visit. Results Satisfactory reduction and bone union were achieved in all patients. There were no statistical significances between the two groups in the demographic data, original postoperative deformities, residual deformities after final correction, external fixation time, and the final clinical outcomes (P > 0.05). The mean number of repeated radiographs after the first radiographs (1.4 times) and mean time to the satisfactory reduction achieved (3.3 days) in patients with an additional foot ring used were all less than those without foot ring (2.4 times, 5.3 days) (P < 0.05). Conclusions The additional foot ring is a practical device to ensure the orthogonality of postoperative radiographs for the hexapod external fixator parameter measurement. Radiation exposure, duration of deformity correction, and cost for patients might be reduced due to the less repeated radiographs with the wrong position.


2021 ◽  
Author(s):  
Yanshi Liu ◽  
Kai Liu ◽  
Feiyu Cai ◽  
Xingpeng Zhang ◽  
Hong Li ◽  
...  

Abstract Background: It is challenging to determine the orthogonality of radiographs in daily clinical practice. The purpose of this study was to show the usefulness of an additional foot ring which might determine the orthogonality of postoperative radiographs for the correction planning of hexapod external fixator.Methods: We retrospectively analyzed 81 consecutive trauma patients with tibial shaft fractures treated by the hexapod external fixator at our institution from September 2014 to July 2019. Starting in March 2016, the postoperative radiographs for fracture reduction planning were obtained under the control of an additional foot ring. In this simple way, the radiologist and the patient himself can easily control the rotation position of the limb while taking the radiographs, and the two X-rays are orthogonal to each other. The final data consisted of 47 patients in traditional radiographs (Group Ⅰ) and 34 patients under the control of foot ring during the radiographic process (Group Ⅱ). The demographic data, original postoperative deformities, number of repeated radiographs after the first postoperative radiological examination, time to the satisfactory reduction achieved, and external fixation time in all patients were documented and analyzed.Results: Satisfactory reduction and bone union were achieved in all patients. There were no statistical significances between the two groups in the demographic data, original postoperative deformities, and external fixation time (P>0.05). The mean number of repeated radiographs after the first postoperative radiological examination (1.2 times) and mean time to the satisfactory reduction achieved (3.0 days) in patients with an additional foot ring used were all less than that (2.1 times, 5.3 days) in patients without foot ring (P<0.05).Conclusions: The additional foot ring is a practical device to ensure the orthogonality of postoperative radiographs for the correction planning of hexapod external fixator. Radiation exposure, duration of deformity correction, and cost for patients might be reduced due to the less repeated radiographs with the wrong position.


Sign in / Sign up

Export Citation Format

Share Document