scholarly journals Effect of screw fixation on acetabular component alignment change in total hip arthroplasty

2014 ◽  
Vol 38 (6) ◽  
pp. 1155-1158 ◽  
Author(s):  
Takaaki Fujishiro ◽  
Shinya Hayashi ◽  
Noriyuki Kanzaki ◽  
Shingo Hashimoto ◽  
Nao Shibanuma ◽  
...  
2017 ◽  
Vol 25 (1) ◽  
pp. 230949901668552 ◽  
Author(s):  
Hironori Ohashi ◽  
Shinichi Kikuchi ◽  
Shigeo Aota ◽  
Michiyuki Hakozaki ◽  
Shinichi Konno

Purpose: Pelvic vascular injury is a serious complication associated with acetabular component setting with screw fixation in cementless total hip arthroplasty (THA). In this study, we investigated the safety zone for acetabular component setting with screw fixation in cementless THA as a means to prevent pelvic vascular injury. Methods: Thirty left hip joints of Japanese cadavers (11 males and 19 females) were analyzed. We used a hemispherical measuring cup with 52 guide holes designed to allow vertical insertion of a Kirschner wire. After the measuring cup was placed on the acetabulum, the Kirschner wire was inserted from each guide hole to examine the anatomical relationship between the acetabulum and the pelvic vessels. We calculated the frequency of pelvic vessel punctures and measured the distance from the acetabular surface to the pelvic vessels at each guide hole. Results: Our findings revealed that pelvic vessels do not exist in certain parts of the posterior area of the acetabulum. Furthermore, in this area, intrapelvic vessels are either lacking or located at a distance ≥31 mm from the surface of the acetabulum. Conclusion: The posterior area of the acetabulum, excluding its central portion, appeared to be the safety zone for acetabular screw fixation in Japanese cadavers.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yukihide Minoda ◽  
Ryo Sugama ◽  
Yoichi Ohta ◽  
Susumu Takemura ◽  
Nobuo Yamamoto ◽  
...  

AbstractThe acetabular component orientation in total hip arthroplasty is of critical importance to clinical results. Although navigation systems and surgical robots have been introduced, most surgeons still use acetabular component alignment guides. This study aimed to compare the accuracy between modern acetabular component alignment guides for the lateral position and those for the supine position. Thirteen alignment guides for the lateral position and 10 for the supine position were investigated. All the lateral position alignment guides indicated cup alignment in operative definition, and the supine position alignment guides indicated cup alignment in radiographic definition. For lateral position alignment guides, the anteversion actually indicated by the alignment guide itself was smaller than that indicated by the manufacturer by a mean of 6° (maximum, 9°), and the inclination actually indicated by alignment guides themselves was larger than that by the manufacturer (p < 0.01) by a mean of 2° (maximum, 4°). For supine position alignment guides, the inclination and anteversion indicated by the alignment guide itself were identical with those indicated by the manufacturer. The current study showed that the angles actually indicated and those stated by manufacturers were not identical for lateral position alignment guides.


2010 ◽  
Vol 25 (6) ◽  
pp. 986-989 ◽  
Author(s):  
Yukihide Minoda ◽  
Kenji Ohzono ◽  
Masaharu Aihara ◽  
Naoya Umeda ◽  
Masuhiro Tomita ◽  
...  

Orthopedics ◽  
2017 ◽  
Vol 40 (4) ◽  
pp. e708-e713 ◽  
Author(s):  
Ameer M. Elbuluk ◽  
Paul Wojack ◽  
Nima Eftekhary ◽  
Jonathan M. Vigdorchik

2012 ◽  
Vol 27 (1) ◽  
pp. 162
Author(s):  
Yukihide Minoda ◽  
Kenji Ohzono ◽  
Masaharu Aihara ◽  
Naoya Umeda ◽  
Masuhiro Tomita ◽  
...  

Author(s):  
Joel Moktar ◽  
Alan Machin ◽  
Habiba Bougherara ◽  
Emil H Schemitsch ◽  
Radovan Zdero

This study provides the first biomechanical comparison of the fixation constructs that can be created to treat transverse acetabular fractures when using the “gold-standard” posterior versus the anterior approach with and without a total hip arthroplasty in the elderly. Synthetic hemipelvises partially simulating osteoporosis (n = 24) were osteotomized to create a transverse acetabular fracture and then repaired using plates/screws, lag screws, and total hip arthroplasty acetabular components in one of four ways: posterior approach (n = 6), posterior approach plus a total hip arthroplasty acetabular component (n = 6), anterior approach (n = 6), and anterior approach plus a total hip arthroplasty acetabular component (n = 6). All specimens were biomechanically tested. No differences existed between groups for stiffness (range, 324.6–387.3 N/mm, p = 0.629), clinical failure load at 5 mm of femoral head displacement (range, 1630.1–2203.9 N, p = 0.072), or interfragmentary gapping (range, 0.67–1.33 mm, p = 0.359). Adding a total hip arthroplasty acetabular component increased ultimate mechanical failure load for posterior (2904.4 vs. 3652.3 N, p = 0.005) and anterior (3204.9 vs. 4396.0 N, p = 0.000) approaches. Adding a total hip arthroplasty acetabular component also substantially reduced interfragmentary sliding for posterior (3.08 vs. 0.50 mm, p = 0.002) and anterior (2.17 vs. 0.29 mm, p = 0.024) approaches. Consequently, the anterior approach with a total hip arthroplasty may provide the best biomechanical stability for elderly patients, since this fixation group had the highest mechanical failure load and least interfragmentary sliding, while providing equivalent stiffness, clinical failure load, and gapping compared to other surgical options.


2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.