scholarly journals Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up

Author(s):  
J. van Loon ◽  
A. M. J. S. Vervest ◽  
H. M. van der Vis ◽  
I. N. Sierevelt ◽  
D. C. Baas ◽  
...  

Abstract Purpose In press-fit total hip arthroplasty (THA), primary stability is needed to avoid micromotion and hereby aseptic loosening, the main reason for early revision. High aseptic loosening revision rates of the seleXys TH+ cup (Mathys Medical) with Ceramys ceramic-on-ceramic (CoC) bearing are seen in literature. Since CoC is presumed to overcome long-term wear-related revisions, the reason for early failure of this cup is important to clarify. The aim is to investigate its ten year outcomes and differentiate between potential causes and identify risk factors for aseptic loosening. Methods Retrospective screening of a prospectively documented series of 315 THAs was performed. Primary outcome was cumulative incidence of cup revision due to aseptic loosening. Secondary outcomes were component revision and reoperation. Additionally, potential predictive factors for aseptic loosening were evaluated. Results At the median follow-up of 9.7 years [IQR 4.4; 10.3], 48 TH+ (15.2%) were revised due to aseptic loosening. Competing risk analysis showed a ten year cumulative incidence of cup revision due to aseptic loosening of 15.6% (95% CI 12.0–20.2). Stabilization of early revision rates was observed, following a high rate of respectively 81.3% (n = 39) and 95.8% (n = 46) within the first two and three years. No significant predictive factors for aseptic loosening were found. Conclusion The ten year results of seleXys TH+ cup with Ceramys CoC bearing showed an unacceptable high aseptic loosening rate, which stabilized over time after a high early failure incidence. This could be attributed to a problem with osseointegration during the transition of primary to definitive stability.

2008 ◽  
Vol 20 (2) ◽  
pp. 91 ◽  
Author(s):  
Song Lee ◽  
Jin Hak Kim ◽  
Dong Oh Ko ◽  
Young Won Jeon ◽  
Seung Jin Yang ◽  
...  

2018 ◽  
Vol 28 (2) ◽  
pp. 133-138 ◽  
Author(s):  
Yeong J. Lau ◽  
Shashank Sarmah ◽  
Johan D. Witt

Introduction: 3rd generation ceramic bearings were introduced in total hip arthroplasty (THA) with the potential to have better mechanical strength and wear properties than their predecessors. At present, there are few studies looking at the long-term results of this latest generation of ceramic bearings. The purpose of our study was to investigate the long-term clinical and radiographic results of 3rd generation ceramic-on-ceramic THA and the incidence of ceramic specific complications such as squeaking and bearing surface fracture. Methods: The database of the senior author (J.D.W.) was reviewed. A total of 126 hip replacements performed in 108 patients (average age 39.6 years) with an average follow-up of 12.1 years (10-16 years) was identified. Clinical notes and plain radiographs were reviewed. To measure function, patients were contacted and an Oxford Hip Questionnaire was completed. Patients were also directly questioned about the presence of squeaking or any other sounds from the hip. Radiographs were evaluated for signs of wear, osteolysis, loosening and heterotopic ossification. The abduction angle of the acetabular component was measured. Results: The average Oxford Hip Score was 39.8 out of 48. Survivorship at 10 years was 94.6% (95% CI) with revision for any cause as the endpoint. There was 1 femoral head fracture, no osteolysis, no squeaking and no detectable wear. Conclusions: The good clinical and radiographic results for this series of patients are similar to other recent long-term studies looking at 3rd generation ceramic-on-ceramic THA. The results compare favourably with other bearing surfaces. The lack of osteolysis associated with this articulation is encouraging and may also make it a good choice for younger patients requiring total hip replacement.


2019 ◽  
Vol 101-B (3) ◽  
pp. 311-316 ◽  
Author(s):  
J. Löchel ◽  
V. Janz ◽  
C. Hipfl ◽  
C. Perka ◽  
G. I. Wassilew

Aims The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique. Patients and Methods Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity. Results The overall survival of the acetabular component at a mean of ten years postoperatively was 92.5%. Three hips (5.6%) required further revision due to aseptic loosening, and one (1.9%) required revision for infection. Three hips with aseptic loosening failed, due to insufficient screw fixation of the shell in two and pelvic discontinuity in one. The mean Harris Hip Score improved significantly from 55 (35 to 68) preoperatively to 81 points (68 to 99) at the latest follow-up (p < 0.001). Conclusion The reconstruction of acetabular defects with TM shells and augments showed excellent long-term results. Supplementary screw fixation of the shell should be performed in every patient. Alternative techniques should be considered to address pelvic disconinuity. Cite this article: Bone Joint J 2019;101-B:311–316.


2018 ◽  
Vol 29 (6) ◽  
pp. 603-608 ◽  
Author(s):  
Yingyong Suksathien ◽  
Jithayut Sueajui

Purpose: To evaluate the clinical and radiographic mid-term results of short-stem total hip arthroplasty (THA) in patients with osteonecrosis of the femoral head (ONFH). Methods: We reviewed 83 cases that underwent Metha stem between November 2010 and November 2012. The appearance of bone trabeculae development and radiolucent line were reviewed and HHS was recorded at 6 months postoperatively then yearly to evaluate the clinical results. Results: The mean age of patients was 43.8 years with the mean follow-up 69.3 (60–84) months. Harris Hip Score improved significantly from 44.7 preoperatively to 99.6 at the last follow-up ( p < 0.0001). There were 4 cases (4.8%) of intraoperative femoral fractures. There was 1 case (1.2%) of distal stem perforation that had stable bone ingrowth and there was 1 case (1.2%) of 5-mm subsidence, which was then stable at 3 months postoperatively. Bone trabecular development was detected at zone 1 (65.1%), 2 (69.9%), 3 (14.4%), 4 (1.2%), 6 (97.6%) and 7 (81.9%). There was 1 case (1.2%) where radiolucent lines were observed in zones 1 and 7. There was 1 femoral stem revision from periprosthetic fracture 4 years after index surgery and 1 cup revision from aseptic loosening. Kaplan-Meier survivorship with the end point of stem revision for any reason was 98.8% and for aseptic loosening it was 100% at 7 years. Conclusions: The mid-term clinical and radiographic results of the Metha stem in patients with ONFH were promising. Its design enables preservation of the bone stock and the bone trabeculae appear to confirm the assumption of proximal force transmission.


2018 ◽  
Vol 100-B (11) ◽  
pp. 1434-1441 ◽  
Author(s):  
W. G. Blakeney ◽  
Y. Beaulieu ◽  
B. Puliero ◽  
M. Lavigne ◽  
A. Roy ◽  
...  

Aims This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41.


2006 ◽  
Vol 309-311 ◽  
pp. 1357-1362
Author(s):  
Masahiro Hasegawa ◽  
Akihiro Sudo ◽  
Atsumasa Uchida

In ceramic-on-ceramic total hip arthroplasty (THA), modular acetabular component with a sandwich insertion was developed and evaluated mid-term clinical results. 35 hips had undergone cementless ceramic-on-ceramic THA with sandwich cup (Kyocera, Kyoto, Japan). The mean duration of follow-up was 5 years. 6 hips had undergone component revisions. The reasons for revision included infection in 1 hip, dislocation with loosening in 2 hips, alumina liner fractures in 2 hips, and cup dissociation in 1 hip. All femoral and acetabular components showed no loosening in the unrevised hips at the time of the last follow-up. None of the 29 unrevised hips had osteolysis.


2003 ◽  
Vol 13 (2) ◽  
pp. 94-100
Author(s):  
M.J.F. Diks ◽  
M. Spruit ◽  
J.J. Reimering ◽  
F. Den Boer ◽  
P.G. Anderson

Aseptic loosening in total hip arthroplasty can lead to proximal femoral periprosthetic bone loss. The non-cemented Wagner revision stem achieves primary fixation in the diaphysis. The purpose of this study is to evaluate the results after medium- to long-term follow-up of the Wagner prosthesis for revision of the femoral component for aseptic loosening in total hip arthroplasty with proximal femoral bone loss. We performed 53 femoral revisions for aseptic loosening with the non-cemented Wagner revision stem. Clinical assessment included a modified Harris Hip Score and a radiological evaluation. The mean follow-up was 65 months. The Harris Hip Score improved significantly (42.9 to 72.3). Radiological evaluation revealed 24.5% subsidence (>5 mm) in our population. Nine re-revisions were done, eight in the first post-operative year. The re-revisions were performed for progressive subsidence (five), recurrent dislocations (one), subsidence with low-grade infection (one), false route (one), and aseptic loosening after 75 months (one). The cumulative survival rate of the Wagner stem after 12 months was 85% and 76% after 75 months. A relatively high re-revision rate was observed during the first post-operative year. Analysis of these failures has shown that subsidence may be the result of insufficient primary stability. Adequate pre-operative planning and intra-operative radiological assistance is necessary for perfect primary stability and fixation of the Wagner stem. The re-revision incidence after the first 12 months is 0.45 per 100 implants per year. The prosthesis has good survival potential after proper introduction.