Letter to the editor regarding “Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up” by Loon et al.

Author(s):  
Weifeng Ji ◽  
Jing Shen
Author(s):  
J. van Loon ◽  
A. M. J. S. Vervest ◽  
H. M. van der Vis ◽  
I. N. Sierevelt ◽  
D. C. Baas ◽  
...  

Abstract Purpose In press-fit total hip arthroplasty (THA), primary stability is needed to avoid micromotion and hereby aseptic loosening, the main reason for early revision. High aseptic loosening revision rates of the seleXys TH+ cup (Mathys Medical) with Ceramys ceramic-on-ceramic (CoC) bearing are seen in literature. Since CoC is presumed to overcome long-term wear-related revisions, the reason for early failure of this cup is important to clarify. The aim is to investigate its ten year outcomes and differentiate between potential causes and identify risk factors for aseptic loosening. Methods Retrospective screening of a prospectively documented series of 315 THAs was performed. Primary outcome was cumulative incidence of cup revision due to aseptic loosening. Secondary outcomes were component revision and reoperation. Additionally, potential predictive factors for aseptic loosening were evaluated. Results At the median follow-up of 9.7 years [IQR 4.4; 10.3], 48 TH+ (15.2%) were revised due to aseptic loosening. Competing risk analysis showed a ten year cumulative incidence of cup revision due to aseptic loosening of 15.6% (95% CI 12.0–20.2). Stabilization of early revision rates was observed, following a high rate of respectively 81.3% (n = 39) and 95.8% (n = 46) within the first two and three years. No significant predictive factors for aseptic loosening were found. Conclusion The ten year results of seleXys TH+ cup with Ceramys CoC bearing showed an unacceptable high aseptic loosening rate, which stabilized over time after a high early failure incidence. This could be attributed to a problem with osseointegration during the transition of primary to definitive stability.


2008 ◽  
Vol 20 (2) ◽  
pp. 91 ◽  
Author(s):  
Song Lee ◽  
Jin Hak Kim ◽  
Dong Oh Ko ◽  
Young Won Jeon ◽  
Seung Jin Yang ◽  
...  

2018 ◽  
Vol 28 (2) ◽  
pp. 133-138 ◽  
Author(s):  
Yeong J. Lau ◽  
Shashank Sarmah ◽  
Johan D. Witt

Introduction: 3rd generation ceramic bearings were introduced in total hip arthroplasty (THA) with the potential to have better mechanical strength and wear properties than their predecessors. At present, there are few studies looking at the long-term results of this latest generation of ceramic bearings. The purpose of our study was to investigate the long-term clinical and radiographic results of 3rd generation ceramic-on-ceramic THA and the incidence of ceramic specific complications such as squeaking and bearing surface fracture. Methods: The database of the senior author (J.D.W.) was reviewed. A total of 126 hip replacements performed in 108 patients (average age 39.6 years) with an average follow-up of 12.1 years (10-16 years) was identified. Clinical notes and plain radiographs were reviewed. To measure function, patients were contacted and an Oxford Hip Questionnaire was completed. Patients were also directly questioned about the presence of squeaking or any other sounds from the hip. Radiographs were evaluated for signs of wear, osteolysis, loosening and heterotopic ossification. The abduction angle of the acetabular component was measured. Results: The average Oxford Hip Score was 39.8 out of 48. Survivorship at 10 years was 94.6% (95% CI) with revision for any cause as the endpoint. There was 1 femoral head fracture, no osteolysis, no squeaking and no detectable wear. Conclusions: The good clinical and radiographic results for this series of patients are similar to other recent long-term studies looking at 3rd generation ceramic-on-ceramic THA. The results compare favourably with other bearing surfaces. The lack of osteolysis associated with this articulation is encouraging and may also make it a good choice for younger patients requiring total hip replacement.


2018 ◽  
Vol 100-B (11) ◽  
pp. 1434-1441 ◽  
Author(s):  
W. G. Blakeney ◽  
Y. Beaulieu ◽  
B. Puliero ◽  
M. Lavigne ◽  
A. Roy ◽  
...  

Aims This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41.


2006 ◽  
Vol 309-311 ◽  
pp. 1357-1362
Author(s):  
Masahiro Hasegawa ◽  
Akihiro Sudo ◽  
Atsumasa Uchida

In ceramic-on-ceramic total hip arthroplasty (THA), modular acetabular component with a sandwich insertion was developed and evaluated mid-term clinical results. 35 hips had undergone cementless ceramic-on-ceramic THA with sandwich cup (Kyocera, Kyoto, Japan). The mean duration of follow-up was 5 years. 6 hips had undergone component revisions. The reasons for revision included infection in 1 hip, dislocation with loosening in 2 hips, alumina liner fractures in 2 hips, and cup dissociation in 1 hip. All femoral and acetabular components showed no loosening in the unrevised hips at the time of the last follow-up. None of the 29 unrevised hips had osteolysis.


2018 ◽  
Vol 29 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Yoshitoshi Higuchi ◽  
Taisuke Seki ◽  
Yukiharu Hasegawa ◽  
Yasuhiko Takegami ◽  
Daigo Morita ◽  
...  

Introduction: This study aimed to compare the clinical and radiographic results of 28-mm ceramic-on-ceramic (CoC) total hip arthroplasty (THA) to those of 32-mm CoC during a 5- to 15-year follow-up period. Methods: 107 joints (95 women and 6 men) underwent 28-mm CoC, and 60 (49 women and 7 men) underwent 32-mm CoC. The average patient age at the time of surgery was 56.1 and 55.7 years in the 28-mm and 32-mm CoC groups, respectively. Clinical and radiologic measurements of all patients were analysed. Results: The mean preoperative Harris hip score (HHS) was similar in the 2 groups (28-mm, 58.9; and 32-mm, 58.5). However, at final follow-up, the mean HHS of the 32-mm CoC (91.8) was significantly better than that of the 28-mm CoC (88.2) ( p = 0.003), as were the ranges of motion (ROM) for flexion (98.3 ± 13.5° vs. 87.3 ± 19.3°, p < 0.001) and abduction (27.8 ± 14.9° vs. 22.1 ± 19.3°, p = 0.007). The mean wear rate was 0.0044 mm/year for the 28-mm CoC and 0.0044 mm/year for the 32-mm CoC. No ceramic fractures were found in the 2 groups. One joint in the 28-mm CoC (0.9%) required revision owing to progressive osteolysis. Kaplan-Meier survival at 10 years, with implant loosening or revision THA as the endpoint, was 98.3% for 28-mm CoC and 100% for 32-mm CoC ( p = 0.465). Conclusion: There was no significant difference in ceramic-related complications between the 2 groups. Our study demonstrated that the 32-mm and 28-mm CoC are safe and are associated with good clinical outcomes.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Hou-Tsung Chen ◽  
Cheng-Ta Wu ◽  
Tsan-Wen Huang ◽  
Hsin-Nung Shih ◽  
Jun-Wen Wang ◽  
...  

Using morselized and structural allograft to restore bone stock for massive acetabular bone defect in revision total hip arthroplasty (THA) is an appealing procedure. However, concerns about inability to achieve long-term stability following allograft resorption remained. From 2003 to 2012, 59 hips in 58 patients undergoing revision THA for Paprosky type II or III acetabular defects were retrospectively reviewed. The acetabular defects were managed with deep-frozen morselized and structural allografts, and a press-fit cementless cup along with supplementary screws. Clinical outcomes and radiographic results were analyzed with a mean follow-up of 8.7 years. The clinical successful rate was 100% for hips with Paprosky type II defect, 95.2% for IIIA defect, and 92.8% for IIIB defect. Three hips with type III defect failed at 4, 7, and 9 years, respectively. Harris Hip Score improved significantly from 60.1 preoperatively to 91.3 at the latest follow-up. All hips with good clinical results showed trabecular bridging in the allograft-host bone interface. Deep-frozen structural and morselized allograft in combination with a press-fit cementless cup represented a viable option to reconstruct acetabular defects in revision THA.