A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety

2015 ◽  
Vol 25 (11) ◽  
pp. 3354-3360 ◽  
Author(s):  
Daniel Yaffe ◽  
Matthew Koslow ◽  
Hassan Haskiya ◽  
David Shitrit
Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1068
Author(s):  
Daniel Gulias-Soidan ◽  
Nilfa Milena Crus-Sanchez ◽  
Daniel Fraga-Manteiga ◽  
Juan Ignacio Cao-González ◽  
Vanesa Balboa-Barreiro ◽  
...  

Background: The aim of this study was to evaluate the diagnostic capacity of Cone-Beam computed tomography (CT)-guided transthoracic percutaneous biopsies on lung lesions in our setting and to detect risk factors for possible complications. Methods: Retrospective study of 98 biopsies in 94 patients, performed between May 2017 and January 2020. To obtain them, a 17G coaxial puncture system and a Siemens Artis Zee Floor vc21 archwire were used. Descriptive data of the patients, their position at the time of puncture, location and size of the lesions, number of cylinders extracted, and complications were recorded. Additionally, the fluoroscopy time used in each case, the doses/area and the estimated total doses received by the patients were recorded. Results: Technical success was 96.8%. A total of 87 (92.5%) malignant lesions and 3 (3.1%) benign lesions were diagnosed. The sensitivity was 91.5% and the specificity was 100%. We registered three technical failures and three false negatives initially. Complications included 38 (38.8%) pneumothorax and 2 (2%) hemoptysis cases. Fluoroscopy time used in each case was 4.99 min and the product of the dose area is 11,722.4 microGy/m2. Conclusion: The transthoracic biopsy performed with Cone-Beam CT is accurate and safe in expert hands for the diagnosis of lung lesions. Complications are rare and the radiation dose used was not excessive.


2019 ◽  
Vol 8 (6) ◽  
pp. 821 ◽  
Author(s):  
June Hong Ahn ◽  
Jong Geol Jang

In the diagnosis of lung lesions, computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) has a high diagnostic yield and a low complication rate. The procedure is usually performed by interventional radiologists, but the diagnostic yield and safety of CT-guided PTNB when performed by pulmonologists have not been evaluated. A retrospective study of 239 patients who underwent CT-guided PTNB at Yeungnam University Hospital between March 2017 and April 2018 was conducted. A pulmonologist performed the procedure using a co-axial technique with a 20-gauge needle. Then diagnostic yield and safety were assessed. The overall sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of malignancy were 96.1% (171/178), 100% (46/46), 100% (171/171), and 86.8% (46/53), respectively. The diagnostic accuracy was 96.9% (217/224) and the overall complication rate was 33.1% (82/248). Pneumothorax, hemoptysis, and hemothorax occurred in 27.0% (67/248), 5.2% (13/248), and 0.8% (2/248) of the patients, respectively. Univariate analyses revealed that pneumothorax requiring chest tube insertion was a significant risk factor (odds ratio, 25.0; p < 0.001) for diagnostic failure. CT-guided PTNB is a safe procedure with a high diagnostic accuracy, even when performed by an inexperienced pulmonologist. The results were similar to those achieved by interventional radiologists as reported in previously published studies.


Sign in / Sign up

Export Citation Format

Share Document