scholarly journals Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

2016 ◽  
Vol 26 (10) ◽  
pp. 3691-3696 ◽  
Author(s):  
Maciej Guziński ◽  
Łukasz Waszczuk ◽  
Marek J. Sąsiadek
2017 ◽  
Vol 27 (9) ◽  
pp. 3609-3617 ◽  
Author(s):  
Hyun Gi Kim ◽  
Ho-Joon Lee ◽  
Seung-Koo Lee ◽  
Hyun Ji Kim ◽  
Myung-Joon Kim

2011 ◽  
Vol 22 (2) ◽  
pp. 295-301 ◽  
Author(s):  
Alban Gervaise ◽  
Benoît Osemont ◽  
Sophie Lecocq ◽  
Alain Noel ◽  
Emilien Micard ◽  
...  

PLoS ONE ◽  
2014 ◽  
Vol 9 (8) ◽  
pp. e105735 ◽  
Author(s):  
Tsuneo Yamashiro ◽  
Tetsuhiro Miyara ◽  
Osamu Honda ◽  
Hisashi Kamiya ◽  
Kiyoshi Murata ◽  
...  

2017 ◽  
Vol 4 (03) ◽  
pp. 1 ◽  
Author(s):  
Christopher P. Favazza ◽  
Andrea Ferrero ◽  
Lifeng Yu ◽  
Shuai Leng ◽  
Kyle L. McMillan

2016 ◽  
Vol 25 (4) ◽  
pp. 230-234
Author(s):  
Wai-Yung Yu ◽  
Thye Sin Ho ◽  
Henry Ko ◽  
Wai-Yee Chan ◽  
Serene Ong ◽  
...  

Introduction: The use of computed tomography (CT) imaging as a diagnostic modality is increasing rapidly and CT is the dominant contributor to diagnostic medical radiation exposure. The aim of this project was to reduce the effective radiation dose to patients undergoing cranial CT examination, while maintaining diagnostic image quality. Methods: Data from a total of 1003, 132 and 27 patients were examined for three protocols: CT head, CT angiography (CTA), and CT perfusion (CTP), respectively. Following installation of adaptive iterative dose reduction (AIDR) 3D software, tube current was lowered in consecutive cycles, in a stepwise manner and effective radiation doses measured at each step. Results: Baseline effective radiation doses for CT head, CTA and CTP were 1.80, 3.60 and 3.96 mSv, at currents of 300, 280 and 130–150 mA, respectively. Using AIDR 3D and final reduced currents of 160, 190 and 70–100 mA for CT head, CTA and CTP gave effective doses of 1.29, 3.18 and 2.76 mSv, respectively. Conclusion: We demonstrated that satisfactory reductions in the effective radiation dose for CT head (28.3%), CTA (11.6%) and CTP (30.1%) can be achieved without sacrificing diagnostic image quality. We have also shown that iterative reconstruction techniques such as AIDR 3D can be effectively used to help reduce effective radiation dose. The dose reductions were performed within a short period and can be easily achievable, even in busy departments.


Sign in / Sign up

Export Citation Format

Share Document