Simultaneous CO concentration and temperature measurements using tunable diode laser absorption spectroscopy near 2.3 μm

2014 ◽  
Vol 117 (1) ◽  
pp. 7-18 ◽  
Author(s):  
Anup Sane ◽  
Aman Satija ◽  
Robert P. Lucht ◽  
Jay P. Gore
Author(s):  
Ting Xu ◽  
Fei Wang ◽  
Zhishen Jiang ◽  
Jianhua Yan ◽  
Kefa Cen ◽  
...  

CO concentration real-time monitoring in combustion process has great significance in improving combustion efficiency and controlling combustion emissions. No CO-spectroscopy solid state sensors are available at the high temperature of 1600K–2000K in the flames. Gas sensing based on tunable diode laser absorption spectroscopy (TDLAS) with the advantages of high sensitivity, high selectivity, quick response and non-intrusiveness offers the possibility for on-line measurement in combustion environment. CO absorption line located at 2302.12nm is selected for measurement by direct absorption method in premixed C3H8/Air flat flame. Experiment results show that, when equivalence ratio is larger than one, the concentration of CO in the flame is increased with the increase of equivalence ratio. It proves that this method can be used on combustion environment.


2012 ◽  
Vol 61 (23) ◽  
pp. 234204
Author(s):  
Xu Zhen-Yu ◽  
Liu Wen-Qing ◽  
Liu Jian-Guo ◽  
He Jun-Feng ◽  
Yao Lu ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 4234
Author(s):  
Sunghyun So ◽  
Jiyeon Park ◽  
Aran Song ◽  
Jungho Hwang ◽  
Miyeon Yoo ◽  
...  

In a combustion reaction of hydrocarbon fuel, carbon monoxide (CO) is a gas species that is closely related to air pollution generation and combustion efficiency. It has a trade-off with nitrogen oxide and increases rapidly in case of incomplete combustion or in fuel-rich (Φ > 1) environments. Therefore, it is essential to measure CO concentration in order to optimize the combustion condition. In the case of a steel annealing system, the combustion environment is maintained in a deoxidation atmosphere to prevent the formation of an oxide layer on the steel sheet surface. However, it is difficult to measure the CO concentration in a combustion furnace in real-time because of the harsh environment in the furnace. Tunable diode laser absorption spectroscopy, which has the advantages of non-invasiveness, fast response, and in situ measurement-based optical measurement, is highly attractive for measuring the concentration of a certain gas species in a combustion environment. In this study, a combustion system of a partially premixed flamed burner was designed to control the equivalence ratio for fuel-rich conditions. CO concentration was measured using a distributed feedback laser with a wavenumber of 4300.7 cm−1 in the mid-infrared region. The results showed that the CO concentration measured at an equivalence ratio of 1.15 to 1.50 was 0.495% to 6.139%. The detection limit in the combustion environment was analyzed at a path length of 190 cm and an internal temperature of 733 K. The ranges of the peak absorbance were derived as 0.064 and 0.787, which were within the theoretical bounds of 10−3 and 0.80 when the equivalence ratio was varied from 1.15 to 1.50.


2021 ◽  
Vol 16 (2) ◽  
pp. 222-229
Author(s):  
Lin Feng ◽  
Jian Wang ◽  
Chao Ding

Tunable diode laser absorption spectroscopy (TDLAS) technology is adopted herein to detect fire gas produced in the early stage of the fire. Based on this technology, a fire warning detection system with multiple lasers and detectors is proposed. Multiple drivers input laser’s temperature and injected current data, making its output wavelength consistent with the measured gas’ absorption peak wavelengths in absorption spectroscopy. Multiple light beams are coupled to the same optical fiber. After the light beams pass through the long optical path absorption cell filled with fire gas, the beams are separated by a converter. The signals are demodulated by different detectors and further analyzed for fire warnings. After the fire warning system’s design, the system’s various hardware modules are designed, including the light source module, TDLAS controller, gas chamber module, photoelectric detector, and data collection. When the temperature remains unchanged, the output wavelength is linearly related to the injected current. When the injected current remains unchanged, the output wavelength is linearly related to the operating temperature. With a semiconductor laser’s injected current of 40 mA, the initial temperature of 38.6 °C, and the output wavelength of 1578.16 nm, the output wavelength increases continuously as the temperature increases. The harmonic signal amplitude after gas absorption is positively correlated with the measured gas concentration, indicating that the second harmonic signals can estimate the fire gas concentration.