Clinical benefits and oncologic equivalence of self-expandable metallic stent insertion for right-sided malignant colonic obstruction

2016 ◽  
Vol 31 (1) ◽  
pp. 153-158 ◽  
Author(s):  
Woong Bae Ji ◽  
Jung Myun Kwak ◽  
Dong Woo Kang ◽  
Han Deok Kwak ◽  
Jun Won Um ◽  
...  
2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Rintaro Moroi ◽  
Katsuya Endo ◽  
Ryo Ichikawa ◽  
Hiroshi Nagai ◽  
Hirohiko Shinkai ◽  
...  

Objectives.Self-expandable metallic stent (SEMS) is widely used to treat malignant colonic obstruction. However, most reports about SEMS insertion have concentrated on the left colon. This study aimed to (1) investigate the effectiveness of SEMS insertion compared with conventional decompression tube for right-sided colonic obstruction and (2) compare the safety and technical success of SEMS insertion between left- and right-sided colonic obstructions.Methods.The data from thirty-seven patients who underwent SEMS or conventional decompression tube placement for malignant colonic obstruction in our hospital were analyzed retrospectively. Technical and clinical success, complications, and technical difficulties were analyzed. We compared the results between SEMS insertion and decompression tube placement in right colons and the outcomes of SEMS insertion between right- and left-sided colonic obstructions.Results.For right colons, the clinical success rate of SEMS insertion (100%) was significantly higher than that of decompression tube placement (55.9%). Concerning SEMS insertion, the technical difficulty and safety of SEMS insertion were similar between right- and left-sided colonic obstructions.Conclusion.SEMS insertion for right-sided colon is significantly more effective than conventional decompression tube placement, and this procedure was safer and less technically challenging than expected. SEMS insertion should be considered for treating right-sided malignant colonic obstruction.


2018 ◽  
Vol 57 (3) ◽  
pp. 329-332 ◽  
Author(s):  
Akinari Takao ◽  
Taku Tabata ◽  
Koichi Koizumi ◽  
Go Kuwata ◽  
Satomi Shibata ◽  
...  

2001 ◽  
Vol 52 (2) ◽  
pp. 75-81
Author(s):  
Hideo Shimada ◽  
Osamu Chino ◽  
Takayuki Nishi ◽  
Hikaru Tanaka ◽  
Yoshifumi Kise ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Yadong Feng ◽  
Qian Yu ◽  
Ming Li ◽  
Wei Xu ◽  
Ye Zhu ◽  
...  

Aims. Endoscopic self-expandable metallic stent (SEMS) insertion for acute colonic obstruction caused by colorectal cancer (CRC) is always performed under fluoroscopic guidance. This study evaluated the feasibility and safety of an endoscopic stenting procedure without fluoroscopic guidance. Methods. A total of 36 patients with an acute colonic obstruction caused by CRC underwent endoscopic SEMS insertion using a colonoscope without fluoroscopic guidance, followed by analyses of the technical and clinical success and short-term complications. Results. Total technical success rate and clinical success rate were 91.7% and 86.1%, respectively. The mean procedure time was 21.2±10.3 minutes. There was no stent dislodgement. One case of hematochezia and two cases of tenesmus occurred in patients with left-sided complete obstructions. No other short-term complications occurred. Procedure time, technical success, and clinical success rate were 16.3±9.4 minutes, 93.1%, and 89.6% for left-sided obstructions, respectively, and were 26.8±10.7 minutes, 85.7%, and 71.4% for right-sided obstructions, respectively. For complete obstructions, procedure time, technical success, and clinical success rate were 22.5±8.9 minutes, 90%, and 83.3%, respectively. In the incomplete cases, procedure time, technical success, and clinical success were 13.5±6.7 minutes, 100%, and 100%, respectively. Technical success, clinical success, and short-term complications were not differed between lesion locations and degrees. Conclusions. This simple technique is feasible and safe for palliation of acute colonic obstruction caused by CRC.


2015 ◽  
Vol 78 (1) ◽  
pp. 31 ◽  
Author(s):  
Sung Bae Cho ◽  
Seon Ah Cha ◽  
Joon Young Choi ◽  
Jong Min Lee ◽  
Hyeon Hui Kang ◽  
...  

2019 ◽  
Vol 07 (01) ◽  
pp. E26-E35 ◽  
Author(s):  
Benedetto Mangiavillano ◽  
Amedeo Montale ◽  
Leonardo Frazzoni ◽  
Mario Bianchetti ◽  
Amrita Sethi ◽  
...  

Abstract Background and aim To assess the rate of adverse events and the technical success rate of biliary stenting with or without EBS.  Methods A literature search up to February 2017 was performed. Studies assessing adverse events (AEs) and technical success rates of stenting with or without EBS were considered. Results Seven studies (870 patients; 12 treatment arms) were included. Early AEs, i. e. those occurring within 30 days, were significantly lower in no-EBS vs. EBS-group (11 % vs. 20.1 %; OR: 0.36, 95 %CI: 0.13 – 1.00). Rates of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis were not significantly different in the two groups (no-EBS vs. EBS: 6.1 % vs 5 %; OR: 1.33, 95 %CI: 0.68 – 2.59). The rate of bleeding was significantly lower in patients without EBS (no-EBS vs EBS: 0 % vs 5 %; OR: 0.12, 95 % CI: 0.03 – 0.45). Rates of cholangitis were significantly lower in patients without EBS (no-EBS vs. EBS: 3.3 % vs. 7.4 %; OR: 0.38, 95 %CI: 0.17 – 0.83). Both late AEs and mortality rates did not significantly differ between no-EBS and EBS patients (19.9 % vs. 18.9 %; OR: 0.93, 95 %CI: 0.56 – 1.53, and 2.5 % vs. 2.9 %; OR: 1.18, 95 %CI: 0.22 – 6.29, respectively). The technical success rate for stent insertion also did not differ (98 % vs. 97.6 %; OR: 1.05, 95 %CI: 0.42 – 2.63). Conclusion EBS seems to be associated, in the first 30 days after the procedure, with an increased risk of cholangitis and bleeding. No difference was observed in the rate of post-ERCP pancreatitis.


Sign in / Sign up

Export Citation Format

Share Document