A new ovine model of spine and chest wall deformity at birth with alteration of respiratory system mechanics and lung development: a feasibility study

2018 ◽  
Vol 28 (1) ◽  
pp. 114-120 ◽  
Author(s):  
Stefan Parent ◽  
Nathalie Samson ◽  
Jesse Shen ◽  
Gabriel Gutman ◽  
Sarah Bouchard ◽  
...  
Author(s):  
Ferenc Peták ◽  
Roberta Südy ◽  
Gergely Fodor ◽  
Andre Dos Santos Rocha ◽  
József Tolnai ◽  
...  

1995 ◽  
Vol 21 (10) ◽  
pp. 808-812 ◽  
Author(s):  
G. Conti ◽  
V. Vilardi ◽  
M. Rocco ◽  
R. A. DeBlasi ◽  
A. Lappa ◽  
...  

1991 ◽  
Vol 71 (6) ◽  
pp. 2425-2433 ◽  
Author(s):  
G. Polese ◽  
A. Rossi ◽  
L. Appendini ◽  
G. Brandi ◽  
J. H. Bates ◽  
...  

In ten mechanically ventilated patients, six with chronic obstructive pulmonary disease (COPD) and four with pulmonary edema, we have partitioned the total respiratory system mechanics into the lung (l) and chest wall (w) mechanics using the esophageal balloon technique together with the airway occlusion technique during constant-flow inflation (J. Appl. Physiol. 58: 1840–1848, 1985). Intrinsic positive end-expiratory pressure (PEEPi) was present in eight patients (range 1.1–9.8 cmH2O) and was due mainly to PEEPi,L (80%), with a minor contribution from PEEPi,w (20%), on the average. The increase in respiratory elastance and resistance was determined mainly by abnormalities in lung elastance and resistance. Chest wall elastance was slightly abnormal (7.3 +/- 2.2 cmH2O/l), and chest wall resistance contributed only 10%, on the average, to the total. The work performed by the ventilator to inflate the lung (WL) averaged 2.04 +/- 0.59 and 1.25 +/- 0.21 J/l in COPD and pulmonary edema patients, respectively, whereas Ww was approximately 0.4 J/l in both groups, i.e., close to normal values. We conclude that, in mechanically ventilated patients, abnormalities in total respiratory system mechanics essentially reflect alterations in lung mechanics. However, abnormalities in chest wall mechanics can be relevant in some COPD patients with a high degree of pulmonary hyperinflation.


1992 ◽  
Vol 72 (2) ◽  
pp. 575-582 ◽  
Author(s):  
T. Mutoh ◽  
W. J. Lamm ◽  
L. J. Embree ◽  
J. Hildebrandt ◽  
R. K. Albert

The effect of severe generalized edema on respiratory system mechanics is not well described. We measured airway pressure, gastric pressure, and four vertical pleural pressures in 13 anesthetized paralyzed pigs ventilated in the upright position. Pressure-volume relationships of the respiratory system, chest wall, and lung were measured on deflation from total lung capacity to residual volume and during tidal breathing both before (control) and 50 min after one of two interventions. In one series of experiments, a volume equal to 15–20% of the pig's body weight was infused intravenously. In a second series, a balloon was placed in the peritoneal space to distend the abdomen to the same gastric pressures as achieved in the first series. Measurements were compared before and after either abdominal balloon inflation or volume infusion. Volume infusion increased the pleural pressure in dependent lung regions, decreased both total lung capacity (34%) and functional residual capacity (62%) (both P less than 0.05), and markedly shifted the respiratory system and chest wall pressure-volume curves to the right, but it only moderately affected the lung deflation curve. Tidal compliances of the respiratory system, chest wall, and lung decreased 36, 31, and 49%, respectively (all P less than 0.05). The effect of abdominal balloon inflation on respiratory system mechanics was similar to that of volume infusion. We conclude that infusing large volumes of fluid markedly alters chest wall mechanics, mainly by causing abdominal distension that prohibits descent of the diaphragm.


1989 ◽  
Vol 42 (4) ◽  
pp. 484-486 ◽  
Author(s):  
Sanjeev N. Deshpande ◽  
Sheetal R. Jagtap ◽  
Ravin L. Thatte

1992 ◽  
Vol 73 (2) ◽  
pp. 427-433 ◽  
Author(s):  
Z. Hantos ◽  
A. Adamicza ◽  
E. Govaerts ◽  
B. Daroczy

In nine anesthetized and paralyzed cats, the mechanical impedances of the total respiratory system (Zrs) and the lungs (ZL) were measured with small-volume pseudorandom forced oscillations between 0.2 and 20 Hz. ZL was measured after thoracotomy, and chest wall impedance (Zw) was calculated as Zw = Zrs-ZL. All impedances were determined by using input airflow [input impedance (Zi)] and output flow measured with a body box [transfer impedance (Zt)]. The differences between Zi and Zt were small for Zrs and negligible for ZL. At 0.2 Hz, the real and imaginary parts of ZL amounted to 33 +/- 4 and 35 +/- 3% (SD), respectively, of Zrs. Up to 8 Hz, all impedances were consistent with a model containing a frequency-independent resistance and inertance and a constant-phase tissue part (G-jH)/omega alpha, where G and H are coefficients for damping and elastance, respectively, omega is angular frequency, and alpha determines the frequency dependence of the real and imaginary parts. G/H was higher for Zw than for ZL (0.29 +/- 0.05 vs. 0.22 +/- 0.04, P less than 0.01). In four cats, the amplitude dependence of impedances was studied: between oscillation volumes of 0.8 and 3 ml, GL, HL, Gw, and Hw decreased on average by 3, 9, 26, and 29%, respectively, whereas the change in G/H was small for both ZL (7%) and Zw (-4%). The values of H were two to three times higher than the quasistatic elastances estimated with greater volume changes (greater than 20 ml).


2007 ◽  
Vol 125 (1) ◽  
pp. 9-14 ◽  
Author(s):  
Fábio Ely Martins Benseñor ◽  
Joaquim Edson Vieira ◽  
José Otávio Costa Auler Júnior

CONTEXT AND OBJECTIVE: Thoracic epidural anesthesia (TEA) following thoracic surgery presents known analgesic and respiratory benefits. However, intraoperative thoracic sympathetic block may trigger airway hyperreactivity. This study weighed up these beneficial and undesirable effects on intraoperative respiratory mechanics. DESIGN AND SETTING: Randomized, double-blind clinical study at a tertiary public hospital. METHODS: Nineteen patients scheduled for partial lung resection were distributed using a random number table into groups receiving active TEA (15 ml 0.5% bupivacaine, n = 9) or placebo (15 ml 0.9% saline, n = 10) solutions that also contained 1:200,000 epinephrine and 2 mg morphine. Under general anesthesia, flows and airway and esophageal pressures were recorded. Pressure-volume curves, lower inflection points (LIP), resistance and compliance at 10 ml/kg tidal volume were established for respiratory system, chest wall and lungs. Student’s t test was performed, including confidence intervals (CI). RESULTS: Bupivacaine rose 5 ± 1 dermatomes upwards and 6 ± 1 downwards. LIP was higher in the bupivacaine group (6.2 ± 2.3 versus 3.6 ± 0.6 cmH2O, p = 0.016, CI = -3.4 to -1.8). Respiratory system and lung compliance were higher in the placebo group (respectively 73.3 ± 10.6 versus 51.9 ± 15.5, p = 0.003, CI = 19.1 to 23.7; 127.2 ± 31.7 versus 70.2 ± 23.1 ml/cmH2O, p < 0.001, CI = 61 to 53). Resistance and chest wall compliance showed no difference. CONCLUSION: TEA decreased respiratory system compliance by reducing its lung component. Resistance was unaffected. Under TEA, positive end-expiratory pressure and recruitment maneuvers are advisable.


2018 ◽  
pp. 83-85
Author(s):  
Subhasis Roy Choudhury

Sign in / Sign up

Export Citation Format

Share Document