Postoperative tooth sensitivity with a new self-adhesive resin cement—a randomized clinical trial

2012 ◽  
Vol 17 (3) ◽  
pp. 793-798 ◽  
Author(s):  
Markus B. Blatz ◽  
Francis K. Mante ◽  
Najeed Saleh ◽  
Alan M. Atlas ◽  
Sahurabh Mannan ◽  
...  
2009 ◽  
Vol 25 (5) ◽  
pp. 601-604 ◽  
Author(s):  
Michael Behr ◽  
Martin Rosentritt ◽  
Jutta Wimmer ◽  
Reinhold Lang ◽  
Carola Kolbeck ◽  
...  

2016 ◽  
Vol 95 (13) ◽  
pp. 1487-1493 ◽  
Author(s):  
N. Hirose ◽  
R. Kitagawa ◽  
H. Kitagawa ◽  
H. Maezono ◽  
A. Mine ◽  
...  

An experimental cavity disinfectant (ACC) that is intended to be used for various direct and indirect restorations was prepared by adding an antibacterial monomer 12-methacryloyloxydodecylpyridinum bromide (MDPB) at 5% into 80% ethanol. The antibacterial effectiveness of ACC and its influences on the bonding abilities of resin cements were investigated. To examine the antibacterial activity of unpolymerized MDPB, the minimum inhibitory and bactericidal concentrations (MIC and MBC) were determined for Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, Parvimonas micra, Enterococcus faecalis, Fusobacterium nucleatum, and Porphyromonas gingivalis. Antibacterial activities of ACC and the commercial cavity disinfectant containing 2% chlorhexidine and ethanol (CPS) were evaluated by agar disk diffusion tests through 7 bacterial species and by MIC and MBC measurement for S. mutans. The effects of ACC and CPS to kill bacteria in dentinal tubules were compared with an S. mutans–infected dentin model. Shear bond strength tests were used to examine the influences of ACC on the dentin-bonding abilities of a self-adhesive resin cement and a dual-cure resin cement used with a primer. Unpolymerized MDPB showed strong antibacterial activity against 7 oral bacteria. ACC produced inhibition zones against all bacterial species similar to CPS. For ACC and CPS, the MIC value for S. mutans was identical, and the MBC was similar with only a 1-step dilution difference (1:2). Treatment of infected dentin with ACC resulted in significantly greater bactericidal effects than CPS ( P < 0.05, analysis of variance and Tukey’s honest significant difference test). ACC showed no negative influences on the bonding abilities to dentin for both resin cements, while CPS reduced the bond strength of the self-adhesive resin cement ( P < 0.05). This study clarified that the experimental cavity disinfectant containing 5% MDPB is more effective in vitro than the commercially available chlorhexidine solution to eradicate bacteria in dentin, without causing any adverse influences on the bonding abilities of resinous luting cements.


2016 ◽  
Vol 42 (12) ◽  
pp. 1819-1821 ◽  
Author(s):  
Stephanie Lemos Martins Sicuro ◽  
Marilisa Carneiro Leão Gabardo ◽  
Carla Castiglia Gonzaga ◽  
Nathaly Dias Morais ◽  
Flares Baratto-Filho ◽  
...  

2010 ◽  
Vol 18 (3) ◽  
pp. 244-248 ◽  
Author(s):  
Guilherme B Guarda ◽  
Luciano S Gonçalves ◽  
Américo B Correr ◽  
Rafael R Moraes ◽  
Mário A.C Sinhoreti ◽  
...  

2015 ◽  
Vol 16 (2) ◽  
pp. 147-153 ◽  
Author(s):  
Mateus Rodrigues Tonetto ◽  
Rudys Rodolfo de Jesus Tavarez ◽  
Omar El-Mowafy ◽  
Matheus Coelho Bandeca ◽  
Thiago Soares Porto ◽  
...  

ABSTRACT Purpose The purpose of this study was to evaluate the effect of self-adhesive and self-etching resin cements on the bond strength of nonmetallic posts in different root regions. Materials and methods Sixty single-rooted human teeth were decoronated, endodontically treated, post-space prepared, and divided into six groups. Glass-fiber (GF) posts (Exacto, Angelus) and fiber-reinforced composite (FRC) posts (EverStick, StickTeck) were cemented with self-adhesive resin cement (Breeze) (SA) (Pentral Clinical) and self-etching resin cement (Panavia-F) (SE) (Kuraray). Six 1-mm-thick rods were obtained from the cervical (C), middle (M), and apical (A) regions of the roots. The specimens were then subjected to microtensile testing in a special machine (BISCO; Schaumburg, IL, USA) at a crosshead speed of 0.5 mm/min. Microtensile bond strength data were analyzed with two-way ANOVA and Tukey's tests. Results Means (and SD) of the MPa were: GF/SA/C: 14.32 (2.84), GF/SA/M: 10.69 (2.72), GF/SA/A: 6.77 (2.17), GF/SE/C: 11.56 (4.13), GF/SE/M: 6.49 (2.54), GF/SE/A: 3.60 (1.29), FRC/SA/C: 16.89 (2.66), FRC/SA/M: 13.18 (2.19), FRC/SA/A: 8.45 (1.77), FRC/SE/C: 13.69 (3.26), FRC/SE/M: 9.58 (2.23), FRC/SE/A: 5.62 (2.12). The difference among the regions was statistically significant for all groups (p < 0.05). The selfadhesive resin cement showed better results than the selfetching resin cement when compared to each post (p < 0.05). No statistically significant differences in bond strengths of the resin cements when comparable to each post (p > 0.05). Conclusion The bond strength values were significantly affected by the resin cement and the highest values were found for self-adhesive resin cement. How to cite this article da Silva MB, de Jesus Tavarez RR, de Assis FS, Tonetto MR, Porto TS, Bhandi SH, El-Mowafy O, de Toledo Porto Neto S, Bandeca MC. The Effect of Self-adhesive and Self-etching Resin Cements on the Bond Strength of Nonmetallic Posts in Different Root Thirds. J Contemp Dent Pract 2015;16(2):147-153.


2018 ◽  
Vol 23 (1) ◽  
pp. 435-444 ◽  
Author(s):  
Luiz Augusto da Costa Poubel ◽  
Cresus Vinicius Deppes de Gouvea ◽  
Fernanda Signorelli Calazans ◽  
Etyene Castro Dip ◽  
Wesley Veltri Alves ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document