Stability-Indicating RP-HPLC Method for Simultaneous Determination of Metformin Hydrochloride and Sitagliptin Phosphate in Dosage Forms

2013 ◽  
Vol 76 (17-18) ◽  
pp. 1153-1162 ◽  
Author(s):  
Ramalingam Peraman ◽  
Chandra Sekhar Gowra ◽  
Y. Padmanabha Reddy ◽  
Krishna Karthik Peruru
2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.


2017 ◽  
Vol 62 (3) ◽  
pp. 3572-3577
Author(s):  
SYED NAEEM RAZZAQ ◽  
MUHAMMAD ASHFAQ ◽  
IRFANA MARIAM ◽  
ISLAM ULLAH KHAN ◽  
SYED SALEEM RAZZAQ ◽  
...  

2017 ◽  
Vol 10 ◽  
pp. S1711-S1725 ◽  
Author(s):  
Mohamed A. Korany ◽  
Rim S. Haggag ◽  
Marwa A.A. Ragab ◽  
Osama A. Elmallah

2010 ◽  
Vol 93 (4) ◽  
pp. 1086-1092 ◽  
Author(s):  
Anna Gumieniczek ◽  
Anna Berecka ◽  
ukasz Komsta

Abstract For type 2 diabetes treatment, combinations of drugs from the thiazolidinedione and sulfonylurea groups are now available in the same tablet or capsule. Therefore, a stability-indicating and validated HPLC method was developed for simultaneous determination of pioglitazone, rosiglitazone, and glipizide in combined dosage forms. The examined drugs were subjected to different conditions such as acid and base, temperature, and UV light, and degradation of pioglitazone and glipizide was observed under thermal and acidic stress. However, selectivity of the presented method for pioglitazone, rosiglitazone, and glipizide assay against their degradation products was confirmed. It was also demonstrated to be robust, resisting small deliberate changes in pH of the buffer, flow rate, and percentage of acetonitrile in the mobile phase. The presented method utilizes a LiChrospher RP18 column (125 4.0 mm), acetonitrile in phosphate buffer at pH 4.3 (40 + 60, v/v) as the mobile phase, and UV detection at 225 nm for pioglitazone/glipizide or 245 nm for rosiglitazone/glipizide. The method was validated with respect to linearity, precision, and accuracy. Finally, the elaborated procedure was applied for the QC of pioglitazone/glipizide and rosiglitazone/glipizide mixtures.


Sign in / Sign up

Export Citation Format

Share Document