scholarly journals A new stability-indicating RP-HPLC method for the determination of dicyclomine hydrochloride and dimethicone combination in tablet dosage forms

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.

Author(s):  
RAGAA EL SHEIKH ◽  
WAFAA S HASSAN ◽  
EMANH YOUSSEF ◽  
ABDULRAHMAN Y HAMDI ◽  
NAIF AHMED BADAHDAH ◽  
...  

Objective: A new, simple, rapid, sensitive, and accurate stability-indicating high-performance liquid chromatography (HPLC) method was developed and validated for the quantitative determination of linagliptin (LNG) and empagliflozin (EMP) in pure and tablet dosage forms. Methods: An isocratic HPLC method, using a C18 reversed-phase column (150 mm×4.6 mm i.d., particle size 5 μm) with an isocratic binary mobile phase consisting of phosphate buffer and acetonitrile (65:35, v/v), was investigated to separate the drug from its stress degradation products. The flow rate was 1.0 mL/min at ambient temperature and photodiode array detector is used at 226 nm for detection. The developed method was validated for system suitability, linearity, accuracy, precision, limits of detection and quantitation, specificity, stability, and robustness. Results: The retention time of LNG and EMP was found to be 3.276±0.002 and 6.966±0.0006 min, respectively. The calibration curve was found to be linear with the equation y=158926.39X+11.139, with a correlation coefficient of R2=0.9991 for LNG and y=22688.45X+4.259, with a correlation coefficient of R2=0.9994 for EMP over a concentration range of 2.5–7.5 μg/mL and 5.0–15 μg/mL for LNG and EMP, respectively. The limits of detection were 0.29 and 0.48 μg/mL for LNG and EMP, respectively, and the limits of quantification were 0.89 and 1.5 μg/mL for LNG and EMP, respectively. The recovery values of this method are 101.11% and 101.48% for LNG and EMP, respectively, and the reproducibility is within 0.070 and 0.277 for LNG and EMP, respectively. Conclusion: The proposed method is a rapid stability-indicating HPLC method that can be applied for the determination of LNG and EMP in pure and tablet dosage forms.


2013 ◽  
Vol 25 (8) ◽  
pp. 4788-4790
Author(s):  
T. Vijaya Bhaskara Reddy ◽  
G. Ramu ◽  
M. Sravan Kumar ◽  
C. Rambabu

2015 ◽  
Vol 14 (10) ◽  
pp. 239 ◽  
Author(s):  
Mohammad Younus ◽  
Md Fasiuddin Arif ◽  
M Paul Richards ◽  
D Bharat Kumar

2010 ◽  
Vol 93 (2) ◽  
pp. 523-530 ◽  
Author(s):  
Sérgio Luiz Dalmora ◽  
Maximiliano da Silva Sangoi ◽  
Daniele Rubert Nogueira ◽  
Lucélia Magalhães da Silva

Abstract An RP-HPLC method was validated for the determination of entecavir in tablet dosage form. The HPLC method was carried out on a Gemini C18 column (150 4.6 mm id) maintained at 30C. The mobile phase consisted of acetonitrilewater (95 + 5, v/v)/potassium phosphate buffer (0.01 M, pH 4; 9 + 91, v/v) pumped at a flow rate of 1.0 mL/min. Photodiode array detection was at 253 nm. The chromatographic separation was obtained with a retention time of 4.18 min, and the method was linear in the range of 0.5200 g/mL (r2 0.9998). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed that there was no interference of the excipients and an increase of the cytotoxicity only by the basic condition. The accuracy was 101.19, with bias lower than 1.81. The LOD and LOQ were 0.39 and 0.5 g/mL, respectively. Method validation demonstrated acceptable results for precision and robustness. The proposed method was applied for the analysis of tablet formulations, to improve QC and assure therapeutic efficacy.


Author(s):  
Bijithra Cholaraja ◽  
Shanmugasundaram P ◽  
Ragan G ◽  
Sankar Ask ◽  
Sumithra M

ABSTRACTObjective: To development and validation of a reversed-phase high-performance liquid chromatography (RP-HPLC) for the determination of modafinilin bulk and pharmaceutical dosage forms.Methods: A simple, precise, rapid, and accurate RP-HPLC method was developed for the estimation of modafinil in bulk and pharmaceutical dosageforms. Xterra RP 18 (250 mm × 4.6 mm, 5 µ particle size) with a mobile phase consisting of methanol:water 70:30 V/V was used. The flow rate1.0 ml/min and the effluents were monitored at 260 nm. The retention time and recovery time was 12 minutes. The detector response was linear inthe concentration of 10-50 µg/ml. The respective linear regression equation being Y=452.1x+65237. The limit of detection and limit of quantificationwere 4.547 and 1.377 mcg, respectively. The method was validated by determining its accuracy, precision, and system suitability.Result: The objective of the present work is to develop simple, precise, and reliable HPLC method for the analysis of modafinil in bulk andpharmaceutical dosage forms. This is achieved using the most commonly employed Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size) columndetection at 260 nm. The present method was validated according to ICH guidelines.Conclusion: In this study, a simple, fast and reliable HPLC method was developed and validated for the determination of modafinil in pharmaceuticalformulations.Keywords: Modafinil, Reversed-phase high-performance liquid chromatography, Estimation, ICH guidelines, Tablets. 


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


Sign in / Sign up

Export Citation Format

Share Document