Development and Validation of Analytical Methods for the Detection and Quantification of a Novel Dimeric Ceramide in Stratum Corneum and Other Layers of the Skin

2016 ◽  
Vol 79 (23-24) ◽  
pp. 1615-1624 ◽  
Author(s):  
Reinhard H. H. Neubert ◽  
Olena Bayrak ◽  
Sophie Steinbach ◽  
Stefan Sonnenberger ◽  
Bodo Dobner
2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Duuamene Nyimanu ◽  
Richard G. Kay ◽  
Petra Sulentic ◽  
Rhoda E. Kuc ◽  
Philip Ambery ◽  
...  

Abstract[Pyr1]apelin-13 is the predominant apelin peptide isoform in the human cardiovascular system and plasma. To date, few studies have investigated [Pyr1]apelin-13 metabolism in vivo in rats with no studies examining its stability in humans. We therefore aimed to develop an LC-MS/MS method for detection and quantification of intact [Pyr1]apelin-13 and have used this method to identify the metabolites generated in vivo in humans. [Pyr1]apelin-13 (135 nmol/min) was infused into six healthy human volunteers for 120 minutes and blood collected at time 0 and 120 minutes after infusion. Plasma was extracted in the presence of guanidine hydrochloride and analysed by LC-MS/MS. Here we report a highly sensitive, robust and reproducible method for quantification of intact [Pyr1]apelin-13 and its metabolites in human plasma. Using this method, we showed that the circulating concentration of intact peptide was 58.3 ± 10.5 ng/ml after 120 minutes infusion. We demonstrated for the first time that in humans, [Pyr1]apelin-13 was cleaved from both termini but the C-terminal was more susceptible to cleavage. Consequently, of the metabolites identified, [Pyr1]apelin-13(1–12), [Pyr1]apelin-13(1–10) and [Pyr1]apelin-13(1–6) were the most abundant. These data suggest that apelin peptides designed for use as cardiovascular therapeutics, should include modifications that minimise C-terminal cleavage.


2019 ◽  
Vol 57 (10) ◽  
pp. 931-938 ◽  
Author(s):  
Mohammad M Kamal ◽  
Sami Nazzal

Abstract Paclitaxel (PTX) and sulforaphane (SFN) are known anticancer molecules. Their activity was found to be potentiated when tested concurrently. Only recently, however, a novel SFN enabled PTX self-microemulsifying formulation (SMEDDS) was developed for their simultaneous delivery. This necessitated the development of an analytical method for the simultaneous detection and quantitation of PTX and SFN. In this study, a simple and sensitive isocratic high performance liquid chromatography-ultraviolet (HPLC-UV) analytical method was developed and validated per International Conference on Harmonization guidelines to satisfy this objective. Its application was demonstrated when quantifying the amount of PTX and SFN released from the SMEDDS in various dissolution media. The separation of the analytes was performed with the aid of a reversed phase C18 column at ambient temperature using a 60:40 mixture of acetonitrile and KH2PO4 buffer (pH 5.0) as the mobile phase. PTX and SFN peaks were detected at 202 nm with high resolution without interference from excipients. This method showed linearity within 2.5–100 μg/mL range with r2 > 0.999. The limit of detection and lower limit of quantitation were 0.1638 and 0.4964 μg/mL for PTX and 0.4419 and 1.3389 μg/mL for SFN, respectively. A total of 98–101% of the injected samples was recovered with RSD of 0.06–0.68% indicating the suitability of the method for the simultaneous detection and quantitation of the molecules in dissolution media.


Sign in / Sign up

Export Citation Format

Share Document