Relationship between hemoglobin A1C and characteristics of plaque vulnerability in stable coronary disease: an optical coherence tomography study

Author(s):  
Hiroki Ueyama ◽  
Keisuke Yasumura ◽  
Naotaka Okamoto ◽  
Yuliya Vengrenyuk ◽  
Nitin Barman ◽  
...  
2016 ◽  
Vol 57 (1) ◽  
pp. 18-24 ◽  
Author(s):  
Ryunosuke Tazaki ◽  
Jun Tanigawa ◽  
Tomohiro Fujisaka ◽  
Kensaku Shibata ◽  
Yoshihiro Takeda ◽  
...  

2020 ◽  
Vol 19 (1) ◽  
Author(s):  
Rosalia Dettori ◽  
Andrea Milzi ◽  
Kathrin Burgmaier ◽  
Mohammad Almalla ◽  
Martin Hellmich ◽  
...  

Abstract Background Type 2 diabetes mellitus (T2DM) is associated with an increased cardiovascular risk related at least in part to a more vulnerable plaque phenotype. However, patients with T2DM exhibit also an increased risk following percutaneous coronary intervention (PCI). It is unknown if plaque vulnerability of a treated lesion influences cardiovascular outcomes in patients with T2DM. In this study, we aimed to assess the association of plaque morphology as determined by optical coherence tomography (OCT) with cardiovascular outcome following PCI in high-risk patients with T2DM. Methods 81 patients with T2DM and OCT-guided PCI were recruited. Pre-interventional OCT and systematic follow-up of median 66.0 (IQR = 8.0) months were performed. Results During follow-up, 24 patients (29.6%) died. The clinical parameters age (HR 1.16 per year, 95% CI 1.07–1.26, p < 0.001), diabetic polyneuropathy (HR 3.58, 95% CI 1.44–8.93, p = 0.006) and insulin therapy (HR 3.25, 95% CI 1.21–8.70, p = 0.019) predicted mortality in T2DM patients independently. Among OCT parameters only calcium-volume-index (HR 1.71 per 1000°*mm, 95% CI 1.21–2.41, p = 0.002) and lesion length (HR 1.93 per 10 mm, 95% CI 1.02–3.67, p = 0.044) as parameters describing atherosclerosis extent were significant independent predictors of mortality. However, classical features of plaque vulnerability, such as thickness of the fibrous cap, the extent of the necrotic lipid core and the presence of macrophages had no significant predictive value (all p = ns). Conclusion Clinical parameters including those describing diabetes severity as well as OCT-parameters characterizing atherosclerotic extent but not classical features of plaque vulnerability predict mortality in T2DM patients following PCI. These data suggest that PCI may provide effective plaque sealing resulting in limited importance of local target lesion vulnerability for future cardiovascular events in high-risk patients with T2DM.


2020 ◽  
Vol 19 (1) ◽  
Author(s):  
Rui Lv ◽  
Akiko Maehara ◽  
Mitsuaki Matsumura ◽  
Liang Wang ◽  
Qingyu Wang ◽  
...  

Abstract Background Detecting coronary vulnerable plaques in vivo and assessing their vulnerability have been great challenges for clinicians and the research community. Intravascular ultrasound (IVUS) is commonly used in clinical practice for diagnosis and treatment decisions. However, due to IVUS limited resolution (about 150–200 µm), it is not sufficient to detect vulnerable plaques with a threshold cap thickness of 65 µm. Optical Coherence Tomography (OCT) has a resolution of 15–20 µm and can measure fibrous cap thickness more accurately. The aim of this study was to use OCT as the benchmark to obtain patient-specific coronary plaque cap thickness and evaluate the differences between OCT and IVUS fibrous cap quantifications. A cap index with integer values 0–4 was also introduced as a quantitative measure of plaque vulnerability to study plaque vulnerability. Methods Data from 10 patients (mean age: 70.4; m: 6; f: 4) with coronary heart disease who underwent IVUS, OCT, and angiography were collected at Cardiovascular Research Foundation (CRF) using approved protocol with informed consent obtained. 348 slices with lipid core and fibrous caps were selected for study. Convolutional Neural Network (CNN)-based and expert-based data segmentation were performed using established methods previously published. Cap thickness data were extracted to quantify differences between IVUS and OCT measurements. Results For the 348 slices analyzed, the mean value difference between OCT and IVUS cap thickness measurements was 1.83% (p = 0.031). However, mean value of point-to-point differences was 35.76%. Comparing minimum cap thickness for each plaque, the mean value of the 20 plaque IVUS-OCT differences was 44.46%, ranging from 2.36% to 91.15%. For cap index values assigned to the 348 slices, the disagreement between OCT and IVUS assignments was 25%. However, for the OCT cap index = 2 and 3 groups, the disagreement rates were 91% and 80%, respectively. Furthermore, the observation of cap index changes from baseline to follow-up indicated that IVUS results differed from OCT by 80%. Conclusions These preliminary results demonstrated that there were significant differences between IVUS and OCT plaque cap thickness measurements. Large-scale patient studies are needed to confirm our findings.


Sign in / Sign up

Export Citation Format

Share Document