scholarly journals Size-exclusion chromatography of cellulose: observations on the low-molar-mass fraction

Cellulose ◽  
2020 ◽  
Vol 27 (16) ◽  
pp. 9217-9225
Author(s):  
Leena Pitkänen ◽  
Herbert Sixta

AbstractAccurate determination of molar mass distribution for disperse cellulose samples has proved to be a challenging task. While size-exclusion chromatography coupled to multi-angle light scattering (MALS) and differential refractive index (DRI) detectors has become the most commonly used method for molar mass determination of celluloses, this technique suffers low sensitivity at the low-molar mass range. As discussed here, the universal method for accurate molar mass distribution analysis of cellulose samples not exists and thus thorough understanding on the differences of the various methodological approaches is important. In this study, the focus is in the accurate determination of the low-molar mass fraction. The results obtained by combining the two calibration strategies, MALS/DRI for polymeric region of a cellulose sample and conventional calibration for oligomeric region, was compared to the results obtained using only MALS/DRI (with extrapolation of the curve where signal-to-noise of MALS is low). For birch pulp sample, the results from the two approaches were comparable; it should be highlighted, however, that MALS/DRI slightly overestimates the molar masses at the low-molar-mass region.

Holzforschung ◽  
2007 ◽  
Vol 61 (4) ◽  
pp. 459-468 ◽  
Author(s):  
Stéphanie Baumberger ◽  
Alfred Abaecherli ◽  
Mario Fasching ◽  
Gäoran Gellerstedt ◽  
Richard Gosselink ◽  
...  

Abstract The reactivity and physicochemical properties of lignins are partly governed by their molar mass distribution. The development of reliable standard methods for determination of the molar mass distribution is not only relevant for designing technical lignins for specific applications, but also for monitoring and elucidating delignification and pulping processes. Size-exclusion chromatography (SEC) offers many advantages, such as wide availability, short analysis time, low sample demand, and determination of molar mass distribution over a wide range. A collaborative study has been undertaken within the “Eurolignin” European thematic network to standardise SEC analysis of technical lignins. The high-molar-mass fraction of polydisperse lignins was shown to be the main source of intra- and interlaboratory variations, depending on the gel type, elution solvent, detection mode, and calculation strategy. The reliability of two widespread systems have been tested: one based on alkali and a hydrophilic gel (e.g., TSK Toyopearl gel) and the other based on THF as solvent and polystyrene-based gels (e.g., Styragel). A set of practical recommendations has been deduced.


Sign in / Sign up

Export Citation Format

Share Document