scholarly journals Correction to: Structural health monitoring of irradiated high-density polyethylene samples with electrical resistance tomography

2021 ◽  
Vol 56 (31) ◽  
pp. 17843-17843
Author(s):  
Shreya Rastogi ◽  
David Bartolo ◽  
Sadi Gurses ◽  
Coleman Kronawitter ◽  
Valeria La Saponara
2020 ◽  
pp. 147592172095112
Author(s):  
Lidor Yosef ◽  
Yiska Goldfeld

The goal of this study is to develop a structural health monitoring methodology for smart self-sensory carbon-based textile reinforced concrete elements. The self-sensory concept is based on measuring the electrical resistance change in the carbon roving reinforcement and by means of an engineering gage factor, correlating the relative electrical resistance change to an integral value of strain along the location of the roving. The concept of the nonlinear engineering gage factor that captures the unique micro-structural mechanism of the roving within the concrete matrix is demonstrated and validated. The estimated value of strain is compared to a theoretical value calculated by assuming a healthy state. The amount of discrepancy between the two strain values makes it possible to indicate and distinguish between the structural states. The study experimentally demonstrates the engineering gage factor concept and the structural health monitoring procedure by mechanically loading two textile reinforced concrete beams, one by a monotonic loading procedure and the other by a cyclic loading procedure. It is presented that the proposed structural health monitoring procedure succeeded in estimating the strain and in clearly distinguishing between the structural states.


2017 ◽  
Vol 3 (3) ◽  
pp. 134
Author(s):  
Egemen Teomete ◽  
Erman Demircilioğlu ◽  
Serap Kahraman

The structures are challenged by earthquakes and other environmental factors. Structural health monitoring is crucial to protect the lives. The strain gages used in structural health monitoring have low durability and can get point wise measurements which limit their use. In this study, five different concrete mixtures with different brass fiber volume fractions were designed. Along with the control mixture which does not have brass fiber, six mixtures were designed and three cube samples from each mixture were cast and cured. Compression test was conducted with simultaneous measurement of electrical resistance. The brass fiber reinforced concrete has strong linear relationship between the electrical resistance change and strain. Important progress was achieved in development of “Smart Concrete” which can sense its strain and damage.


Sign in / Sign up

Export Citation Format

Share Document