scholarly journals Scaling Marker Position Determines the Accuracy of Digital Templating for Total Hip Arthroplasty

2017 ◽  
Vol 14 (1) ◽  
pp. 55-59 ◽  
Author(s):  
Austin J. Ramme ◽  
Nina D. Fisher ◽  
Jonathan Egol ◽  
Gregory Chang ◽  
Jonathan M. Vigdorchik
2016 ◽  
Vol 31 (4) ◽  
pp. 883-887 ◽  
Author(s):  
Christoph K. Boese ◽  
Jan Bredow ◽  
Jens Dargel ◽  
Peer Eysel ◽  
Hansjörg Geiges ◽  
...  

Author(s):  
Christoph Kolja Boese ◽  
Tim Rolvien ◽  
Matthias Trost ◽  
Michael Frink ◽  
Jan Hubert ◽  
...  

Abstract Objective Preoperative digital templating is a standard procedure in total hip arthroplasty. Deviations between template size and final implant size may result from inaccurate calibration, templating as well as intraoperative decisions. So far, the explicit effect of calibration errors on templating has not been addressed adequately. Materials and Methods A mathematical simulation of calibration errors up to ± 24% was applied to the templating of acetabular cups (38 to 72 mm diameter). The effect of calibration errors on template component size as deviation from optimal size was calculated. Results The relationship between calibration error and component size deviation is inverse and linear. Calibration errors have a more pronounced effect on larger component sizes. Calibration errors of 2–6% result in templating errors of up to two component sizes. Common errors of up to 12% may result in templating errors of 3–4 sizes for common implant sizes. A tabular matrix visualizes the effect. Conclusion Calibration errors play a significant role in component size selection during digital templating. Orthopedic surgeons should be aware of this effect and try to identify and address this source of error.


2013 ◽  
Vol 11 (8) ◽  
pp. 662-663
Author(s):  
Stephen McCain ◽  
Laurence Cusick ◽  
Gavan McAlinden

2007 ◽  
Vol 128 (10) ◽  
pp. 1023-1029 ◽  
Author(s):  
Christian Wedemeyer ◽  
Henning Quitmann ◽  
Jie Xu ◽  
Hansjoerg Heep ◽  
Marius von Knoch ◽  
...  

2010 ◽  
Vol 25 (4) ◽  
pp. 529-532 ◽  
Author(s):  
Patrick Gamble ◽  
Justin de Beer ◽  
Danielle Petruccelli ◽  
Mitchell Winemaker

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Emelie Kristoffersson ◽  
Volker Otten ◽  
Sead Crnalic

Abstract Background Total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) is a complex procedure due to associated anatomical abnormalities. We studied the extent to which preoperative digital templating is reliable when performing cementless THA in patients with DDH. Methods We templated and compared the pre- and postoperative sizes of the acetabular and femoral components and the center of rotation (COR), and analysed the postoperative cup coverage, leg length discrepancy (LLD), and stem alignment in 50 patients (56 hips) with DDH treated with THA. Results The implant size exactly matched the template size in 42.9% of cases for the acetabular component and in 38.2% of cases for the femoral component, whereas the templated ±1 size was used in 80.4 and 81.8% of cases for the acetabular and femoral components, respectively. There were no statistically significant differences between templated and used component sizes among different DDH severity levels (acetabular cup: p = 0.30 under the Crowe classification and p = 0.94 under the Hartofilakidis classification; femoral stem: p = 0.98 and p = 0.74, respectively). There were no statistically significant differences between the planned and postoperative COR (p = 0.14 horizontally and p = 0.52 vertically). The median postoperative LLD was 7 (range 0–37) mm. Conclusion Digital preoperative templating is reliable in the planning of cementless THA in patients with DDH.


2020 ◽  
Vol 54 (6) ◽  
pp. 840-847
Author(s):  
Veronica Montiel ◽  
Santiago Troncoso ◽  
Andrés Valentí-Azcárate ◽  
Juan Ramón Valentí-Nin ◽  
Jose María Lamo-Espinosa

Sign in / Sign up

Export Citation Format

Share Document