Assessment of left ventricular contraction patterns using gated SPECT MPI to predict cardiac resynchronization therapy response

2017 ◽  
Vol 25 (6) ◽  
pp. 2029-2038 ◽  
Author(s):  
Ningchao Tao ◽  
Yuanhao Qiu ◽  
Haipeng Tang ◽  
Zhiyong Qian ◽  
Hongping Wu ◽  
...  
2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Amalia Peix ◽  
Kenia Padrón ◽  
Lázaro O. Cabrera ◽  
Osmín Castañeda ◽  
Danet Milán ◽  
...  

Abstract Purpose To analyze the evolution post-cardiac resynchronization therapy (CRT) in left ventricular non-compaction (LVNC) cardiomyopathy (CM) patients compared to other types of CM, according to clinical and functional variables, by using gated-SPECT myocardial perfusion imaging (MPI). Methods Ninety-three patients (60 ± 11 years, 28% women) referred for pre-CRT assessment were studied and divided into three groups: 1 (non-ischemic CM with LVNC, 11 patients), 2 (ischemic CM, 28 patients), and 3 (non-ischemic CM, 53 patients). All were studied by a 99mTc-MIBI gated-SPECT MPI at rest pre-CRT implantation and 6 ± 1 months after, including intraventricular dyssynchrony assessment by phase analysis. Quality of life was measured by the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Results No differences in sex, atherosclerotic risk factors other than smoking habit, and MLHFQ results were found among groups. LVNC CM patients were younger, with greater QRS width and lower left ventricular ejection fraction (LVEF) at baseline, but the differences were not significant. No significant differences were found at baseline regarding ventricular function, although end-systolic volume was slightly higher in LVNC CM patients. Mean SRS was significantly higher (p < 0.0001) in ischemic patients (14.9) versus non-ischemic ones (8.7 in group 1 and 9 in group 2). At baseline, LVNC CM patients were significantly more dyssynchronous: Their phase standard deviation (PSD) was higher (89.5° ± 14.2°) versus groups 2 (65.2° ± 23.3°) and 3 (69.7° ± 21.7°), p = 0.007. Although the quality of life significantly improved in all groups, non-ischemic patients (with or without LVNC) showed a higher LVEF increase and volumes reduction at 6 months post-CRT. Dyssynchrony reduced post-CRT in all groups. Nevertheless, those more dyssynchronous at baseline (LVNC CM) exhibited the most significant intraventricular synchronism improvement: PSD was reduced from 89.5° ± 14.2° at baseline to 63.7° ± 20.5° post-CRT (p = 0.028). Six months post-CRT, 89% of patients were responders: 11 (100%) of those with LVNC CM, 25 (86%) of those with ischemic CM, and 47 (89%) of patients with non-ischemic CM. No patient with LVNC CM had adverse events during the follow-up. Conclusion CRT contributes to a marked improvement in non-ischemic CM patients with non-compaction myocardium. Phase analysis in gated-SPECT MPI is a valuable tool to assess the response to CRT.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
V Saushkin ◽  
YV Varlamova ◽  
AI Mishkina ◽  
DI Lebedev ◽  
SV Popov ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Aim/Introduction: Assessment of mechanical dyssynchrony by myocardial perfusion gated-SPECT in patients with non-ischemic cardiomyopathy for predict response to cardiac resynchronization therapy (CRT). Materials and Methods  We examined 32 patients with non-ischemic cardiomyopathy before and six months after CRT.  Left ventricular mechanical dyssynchrony and contractility were assessed for all patients by myocardial perfusion gated-SPECT. The phase standard deviation (PSD), histogram bandwidth (HBW), phase histogram skewness (S) and phase histogram kurtosis (K) were used as an indicator of mechanical dyssynchrony for the both ventricles.  Results  Mechanical dyssynchrony of both ventricles before CRT was increased in all patients. Median value PSD 53°(41-61°), HBW 176°(136-202°), S 1,62(1,21-1,89), K 2,81(1,21-3,49). Six months after CRT 22(68%) respondents were identified. We divided the patients into two groups (responders and non-responders) and compared phase parameters. It was found that the PSD (44°(35-54°)) and HBW (158°(118-179°) in the responders were significantly lower than in the non-responders (PSD (68°(58-72°); HBW (205°(199-249°)). The value of phase histogram skewness and kurtosis in responders were significantly higher (Responders: S 1,77(1,62-2,02); K 3,03(2,60-3,58). Non-responders: S 1,21(0,93-1,31); K 1,21(0,19-1,46)).  We found that all four indicators of mechanical dyssynchrony can predict CRT response according to the results of univariate logistic regression analysis. Moreover, It was found that only phase histogram kurtosis (OR = 1.196, 95% CI 1.04-1.37) is an independent predictor of CRT response according to multivariate logistic regression. Conclusion  Radionuclide assessment of mechanical dyssynchrony may be the optimal diagnostic method for selecting patients with non-ischemic cardiomyopathy on CRT.


2010 ◽  
Vol 27 (7) ◽  
pp. 831-838 ◽  
Author(s):  
Maria Cristina Porciani ◽  
Francesco Cappelli ◽  
Laura Perrotta ◽  
Marco Chiostri ◽  
Carmelo M. Rao ◽  
...  

Author(s):  
Nithi Tokavanich ◽  
Narut Prasitlumkum ◽  
Wimwipa Mongkonsritragoon ◽  
Angkawipa Trongtorsak ◽  
Wisit Cheungpasitporn ◽  
...  

Heart Rhythm ◽  
2019 ◽  
Vol 16 (5) ◽  
pp. 743-753
Author(s):  
Francis G. Spinale ◽  
Timothy E. Meyer ◽  
Craig M. Stolen ◽  
Jennifer E. Van Eyk ◽  
Michael R. Gold ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document