scholarly journals Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study

2017 ◽  
Vol 6 (2) ◽  
pp. 343-349 ◽  
Author(s):  
Mohamed Nagy Elmohamady ◽  
Walid Abdelghaffar
2020 ◽  
Vol 36 (3) ◽  
pp. 150-159 ◽  
Author(s):  
Jakob Siedlecki ◽  
Valerie Schmelter ◽  
Wolfgang J. Mayer ◽  
Benedikt Schworm ◽  
Siegfried G. Priglinger ◽  
...  

2019 ◽  
Vol 30 (6) ◽  
pp. 1328-1334
Author(s):  
Yi Zhu ◽  
Yu Yue ◽  
Haobin Zhu ◽  
Jili Chen ◽  
Jibo Zhou

Purpose: To investigate the influence of refractive error on pupil diameters in highly myopic eyes with implantable collamer lenses. Setting: Shanghai, China. Design: A prospective consecutive observational study. Methods: Sixty-six eyes of 66 patients that underwent ICL V4c implantation were included. Pupil diameters before and 1 week, 1 month, and 3 months after surgery were measured using an automatic pupillometry system (MonCv3; Metrovision, Pérenchies, France) under four standardized illumination conditions: 0, 1, 10, and 100 cd/m2. The correlations between changes in pupil diameter and spherical equivalent values and patient age were investigated. Results: Based on preoperative spherical equivalent values, included eyes were divided into a high-myopia group (–6.3 to −9.9 D (diopters)) and a super-high-myopia group (–10 to −20 D). Pupil sizes remained unchanged after surgery in the high-myopia group and decreased at 1 and 10 cd/m2 in the super-high-myopia group. A between-group comparison showed that pupils were significantly smaller in the super-high-myopia group 1 week postoperatively under all illumination conditions and remained smaller at 1 month and 3 months under 1 and 10 cd/m2 lighting conditions. Preoperative spherical equivalent values were significantly correlated with the percent decrease in pupil diameter 1 week postoperatively under 0, 1, and 10 cd/m2 illumination conditions; the greater the degree of myopia, the greater the reduction in pupil diameter. Conclusion: Preoperative refractive error significantly affects pupil diameter in highly myopic eyes after implantable collamer lens implantation. Pupils of super highly myopic eyes remained smaller than preoperative levels under mesopic conditions after implantable collamer lens implantation.


2011 ◽  
Vol 52 (5) ◽  
pp. 2444 ◽  
Author(s):  
Yi Pang ◽  
Geoffrey W. Goodfellow ◽  
Christine Allison ◽  
Sandra Block ◽  
Kelly A. Frantz

2020 ◽  
Vol 5 (0) ◽  
pp. 12-16
Author(s):  
Fouad Chraibi ◽  
Hassan Moutei ◽  
Ahmed Bennis ◽  
Meriem Abdellaoui ◽  
Idriss A. Benatiya

Sign in / Sign up

Export Citation Format

Share Document