scholarly journals Which Headless Compression Screw Produces the Highest Interfragmentary Compression Force in Scaphoid Fracture?

2020 ◽  
Vol 54 (5) ◽  
pp. 548-564
Author(s):  
Karthik Vishwanathan ◽  
Ravi Patel ◽  
Sumedh Talwalkar
Hand Surgery ◽  
2010 ◽  
Vol 15 (03) ◽  
pp. 233-234 ◽  
Author(s):  
Shingo Komura ◽  
Yasushi Suzuki ◽  
Tatsuya Ikehata

A case of simultaneous fracture of the waist of the scaphoid and the hook of the hamate is presented. The scaphoid fracture was treated surgically with a headless compression screw, while the hook fracture was treated conservatively with cast immobilisation for eight weeks. Both fractures achieved bone union and the patient returned to work without any symptoms or complications. Only two cases of fractures of the scaphoid and hamate have been reported previously. However, both of them involved fracture of the body of the hamate. This is the first report of simultaneous fracture of the scaphoid and the hook of the hamate.


2012 ◽  
Vol 37 (7) ◽  
pp. 690-693 ◽  
Author(s):  
K. Singisetti ◽  
E. Aldlyami ◽  
A. Middleton

There has been a considerable evolution of screws used for internal fixation of scaphoid fractures. We discuss here, early results of a recently introduced implant Synthes 3.0 mm headless compression screw used for scaphoid fracture fixation. Twenty eight patients with scaphoid fractures (five acute and 23 nonunions) were treated with internal fixation by this non-variable pitch screw over a period of 18 months. All nonunions had pedicle vascularized bone grafting. All five patients with acute scaphoid fracture fixation had radiological healing at a mean of 8 weeks. Fifteen of 23 scaphoid fracture nonunions showed definite signs and a further seven showed probable signs of radiological healing at a mean of 8 months. One nonunion has failed to unite after surgery.


2017 ◽  
Vol 43 (1) ◽  
pp. 93-96 ◽  
Author(s):  
E.S. Tan ◽  
I. S. Mat Jais ◽  
S. Abdul Rahim ◽  
S. C. Tay

We investigated the effect of an interfragmentary gap on the final compression force using the Acutrak 2 Mini headless compression screw (length 26 mm) (Acumed, Hillsboro, OR, USA). Two blocks of solid rigid polyurethane foam in a custom jig were separated by spacers of varying thickness (1.0, 1.5, 2.0 and 2.5 mm) to simulate an interfragmentary gap. The spacers were removed before full insertion of the screw and the compression force was measured when the screw was buried 2 mm below the surface of the upper block. Gaps of 1.5 mm and 2.0 mm resulted in significantly decreased compression forces, whereas there was no significant decrease in compression force with a gap of 1 mm. An interfragmentary gap of 2.5 mm did not result in any contact between blocks. We conclude that an increased interfragmentary gap leads to decreased compression force with this screw, which may have implications on fracture healing.


2015 ◽  
Vol 12 ◽  
pp. S211-S216 ◽  
Author(s):  
Usman Ahmed ◽  
Shahbaz Malik ◽  
Michael David ◽  
Claire Simpson ◽  
Simon Tan ◽  
...  

2019 ◽  
Vol 08 (05) ◽  
pp. 360-365 ◽  
Author(s):  
Samik Patel ◽  
Juan Giugale ◽  
Nathan Tiedeken ◽  
Richard E. Debski ◽  
John R. Fowler

Background Proximal scaphoid fractures display high nonunion rates and increased revision cases. Waist fracture fixation involves maximizing screw length within the cortex; however, the optimal screw length for proximal scaphoid fractures remains unknown. Purpose The main purpose of this article is to compare stiffness and ultimate load for proximal scaphoid fracture fixation of various headless compression screw lengths. Methods Eighteen scaphoids underwent an osteotomy simulating a 7 mm oblique proximal fracture. Screws of three lengths (10, 18, and 24 mm) were randomly assigned for fixation. Each specimen underwent cyclic loading with stiffness calculated during the last loading cycle. Specimens that withstood cyclic loading were loaded to failure. Results No significant difference in stiffness between screw lengths was found. Ultimate load was significantly impacted by the screw length. A significant difference in ultimate load between a 10 and 24 mm screw was found; however, no significant difference occurred in ultimate load between an 18 and 24 mm screw. Conclusions No significant difference in stiffness between all groups could be due to similarities in purchase in the proximal aspect. The 10 mm screw withstanding less ultimate load compared to the 24 mm screw could be due to the 10 mm screw gaining less purchase on either side of the fracture site compared to the 24 mm screw. Lack of significant difference in ultimate load between the 18 and 24 mm screw could be occurring because the fracture site is closer to the 18 mm screw midpoint, as distal threads are engaged closer to the fracture. Clinical Relevance Maximizing screw length may not provide superior fixation biomechanically compared with fixation utilizing a 6 mm shorter screw for proximal scaphoid fractures.


Hand ◽  
2018 ◽  
Vol 13 (6) ◽  
pp. NP39-NP45
Author(s):  
Sheriff D. Akinleye ◽  
Eitan Melamed

Background: Scaphocapitate syndrome is a rare variety of perilunate instability, described as a trans-scaphoid, trans-capitate fracture, with rotation of the capitate head either 90° or 180°. Methods: We present a unique case of scaphocapitate syndrome in which the rotated proximal capitate fragment expelled into the carpal canal. Results: The capitate head was extricated from the carpal tunnel via the volar approach, and was anatomically aligned and fixed through the dorsal approach using two 2.0 mm headless compression screws. The scaphoid fracture was then also reduced through the dorsal approach and stabilized with a 2.5 mm headless compression screw. All intercarpal ligaments appeared intact. Conclusions: Volar dislocation of the proximal capitate into the carpal tunnel in scaphocapitate syndrome presents a unique challenge that can be addressed with a combined volar and dorsal approach.


2017 ◽  
Vol 22 (01) ◽  
pp. 35-38 ◽  
Author(s):  
Eichi Itadera ◽  
Takahiro Yamazaki

We developed a new internal fixation method for extra-articular fractures at the base of the proximal phalanx using a headless compression screw to achieve rigid fracture fixation through a relatively easy technique. With the metacarpophalangeal joint of the involved finger flexed, a smooth guide-pin is inserted into the intramedullary canal of the proximal phalanx through the metacarpal head and metacarpophalangeal joint. Insertion tunnels are made over the guide-pin using a cannulated drill. Then, a headless cannulated screw is placed into the proximal phalanx. All of five fractures treated by this procedure obtained satisfactory results.


Hand ◽  
2021 ◽  
pp. 155894472097411
Author(s):  
Luke T. Nicholson ◽  
Kristen M. Sochol ◽  
Ali Azad ◽  
Ram Kiran Alluri ◽  
J. Ryan Hill ◽  
...  

Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct. Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure. Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( P = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( P = .029). Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.


Sign in / Sign up

Export Citation Format

Share Document