dorsal approach
Recently Published Documents


TOTAL DOCUMENTS

253
(FIVE YEARS 66)

H-INDEX

23
(FIVE YEARS 1)

2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Shun-Min Chang ◽  
Peng-Ju Huang ◽  
Chui Jia Farn ◽  
Shin-Yiing Lin ◽  
Chen-Chie Wang ◽  
...  

Abstract Background The plantar plate is an important static stabilizer of the lesser metatarsophalangeal joints, and disruptions of the plantar plate can lead to significant instability and lesser toe deformities. In recent years, direct plantar plate repair has been proposed. Although direct repair via a dorsal approach is attractive, a torn plantar plate is small and difficult to access using regular instruments in a restricted operative field. Methods In this report, a unique method for plantar plate repairs was used to repair various configurations of plantar plate tears with standard operative instruments that are available in most operating rooms. Results Using this method, 10 patients underwent plantar plate repairs, and the mean follow-up period was 24 (range, 14–38) months. The mean visual analog scale score for pain preoperatively was 4.1 (range, 0–6) and decreased to 0.6 (range, 0–3) at last follow-up. Postoperatively, the mean visual analog scale score for satisfaction was 9.6 (range, 8–10) and the mean American Orthopedic Foot and Ankle Society forefoot score was 88.8 (range, 75–100). Conclusions Our study proposes an inexpensive and versatile method for plantar plate repair via a dorsal approach that uses standard operative instruments. Trial registration ClinicalTrials.gov, NCT04949685. July 2, 2021 - Retrospectively registered, Level of clinical evidence 4


Author(s):  
Vineet Dabas ◽  
Nishant Bhatia ◽  
Gaurang Agrawal

Abstract Background Distal radioulnar joint (DRUJ) dislocation can occur as an isolated injury or in association with fracture radius (Galeazzi fracture-dislocation), Essex–Lopresti lesion or, rarely, with fracture of both radius and ulna (termed “Galeazzi type fracture”). DRUJ dislocations can be simple or complex. While simple DRUJ dislocation can be reduced by closed methods once the associated fractures are fixed anatomically, complex dislocation does not reduce by closed means. A complex DRUJ dislocation occurring in a both bone forearm fracture is an extremely unusual pattern of injury. Case Description We describe the clinical presentation, intraop findings, management, and follow-up of two such cases of both bone forearm fracture with complex DRUJ dislocation. In both the cases, the ulnar head was found to be buttonholed through extensor retinaculum between the extensor tendons. Open reduction had to be done via dorsal approach. Timely intervention allowed good results in both the patients. Literature Review Several authors have reported simple DRUJ dislocations in both bone forearm fractures; however, we could come across only three cases of complex DRUJ dislocation in a both bone forearm fracture. A summary of various series and reports on these injuries is presented. Case Relevance Through this case report, we want to highlight this unusual association and emphasize on sequence of fixation, so that this perilous injury pattern is not missed, and favorable outcomes could be obtained through appropriate and timely intervention.


2021 ◽  
Vol 9 (3) ◽  
pp. 213-218
Author(s):  
Mehmet Ümit ÇETİN ◽  
Abdulkadir SARI ◽  
Fırat FİDAN ◽  
Abdulkadir POLAT ◽  
İsmail Bülent ÖZÇELİK

2021 ◽  
Vol 49 (02) ◽  
pp. e90-e96
Author(s):  
Borja Occhi Gómez ◽  
Ángel García Olea ◽  
Virginia Herrero Sierra

Abstract Introduction Hook of hamate fractures are rare. The best treatment option is a source of debate; it ranges from conservative to surgical techniques, including resection of the hook or a volar approach followed by internal fixation. These techniques are not exempt from risk. Minimal invasive fixation using a dorsal percutaneous approach and a headless, cannulated mini screw is another option, although not commonly considered. We present a case series of patients who underwent this surgical technique. Methods This is a retrospective review of four patients with nondisplaced hook of hamate fractures treated with dorsal percutaneous fixation. The evaluation included symptoms, physical examination, and radiological (radiographs, magnetic resonance imaging [MRI], and computed tomography [CT]) findings, as well as pre and postoperative strength (determined with a Jamar (JLW Instruments, Chicago, USA) hydraulic dynamometer) and quick disabilities of the arm, shoulder and hand (QuickDASH) scores. Results The union rate was 100% with no associated complications. All patients resumed their preinjury activities 3 months after the surgery and reported they would undergo surgery again if needed. Conclusion This retrospective study shows that safe treatment of nondisplaced hook of hamate fractures with percutaneous dorsal fixation is feasible, with excellent clinical outcomes. In any case, our sample is limited, and further studies are required.


2021 ◽  
Vol 2 (15) ◽  
Author(s):  
Guenther C. Feigl ◽  
Domagoj Jugovic ◽  
Daniel Staribacher ◽  
Rolf Buslei ◽  
Dzmitry Kuzmin

BACKGROUND Giant presacral schwannomas are extremely rare in neurosurgery. There are various approaches to the surgical treatment of symptomatic giant presacral schwannomas. The least traumatic is the one-stage surgery with a dorsal approach. OBSERVATIONS The authors describe a case of a 52-year-old male with pain in the sacral region and partial urinary dysfunction. A total tumor resection through a minimally invasive dorsal approach was performed, and anatomical and functional preservation of all sacral nerves with no postoperative complications was achieved. LESSONS The authors have shown the possibility of total tumor resection with a minimally invasive dorsal approach without the development of intra- and postoperative complications. Operative corridors that have been created by a tumor can be used and expanded for a minimally invasive dorsal approach to facilitate resection and minimize tissue disruption.


2021 ◽  
Vol 38 ◽  
pp. 101575
Author(s):  
Qinqin Liu ◽  
Jing Li ◽  
Ke Wu ◽  
Nan You ◽  
Zheng Wang ◽  
...  

Animals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1838
Author(s):  
Alessandro Spadari ◽  
Giulia Forni ◽  
Sara Del Magno ◽  
Claudio Tagliavia ◽  
Marco Canova ◽  
...  

The aims of the present study were to compare the percentages of articular cartilage removed using a lateral drilling approach of the proximal interphalangeal joint (PIPJ) and a dorsal drilling approach, and to assess the usefulness of digital fluoroscopy when performing a lateral drilling approach. Sixty cadaveric PIPJs were drilled using a surgical drill bit to remove the articular cartilage. The limbs were divided into three groups containing 10 forelimbs and 10 hindlimbs each. One group received the dorsal drilling approach, the second one received the lateral drilling approach and the last one received the lateral drilling approach under digital fluoroscopy guidance. The percentage of articular cartilage removed from each articular surface was assessed using Adobe Photoshop ® software. The percentages of removed cartilage turned out to be significantly higher with lateral approach, especially under fluoroscopic guidance, both in the forelimbs (p = 0.00712) and hindlimbs (p = 0.00962). In conclusion, the lateral drilling approach seems to be a minimally invasive technique with which to perform PIPJ arthrodesis, even more efficient than the previously reported dorsal approach.


2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
F. A. Alnaimat ◽  
H. A. Owida ◽  
A. Al Sharah ◽  
M. Alhaj ◽  
Mohammad Hassan

Artificial finger joint design has been developed through different stages through the past. PIP (proximal interphalangeal) and MCP (metacarpophalangeal) artificial finger joints have come to replace the amputation and arthrodesis options; although, these artificial joints are still facing challenges related to reactive tissues, reduced range of motion, and flexion and extension deficits. Swanson silicone artificial finger joints are still common due to the physician’s preferability of silicone with the dorsal approach during operation. Nevertheless, other artificial finger joints such as the pyrocarbon implant arthroplasty have also drawn the interests of practitioners. Artificial finger joint has been classified under three major categories which are constrained, unconstrained, and linked design. There are also challenges such as concerns of infections and articular cartilage necrosis associated with attempted retention of vascularity. In addition, one of the main challenges facing the silicone artificial finger joints is the fracture occurring at the distal stem with the hinge. The aim of this paper is to review the different artificial finger joints in one paper as there are few old review papers about them. Further studies need to be done to develop the design and materials of the pyrocarbon and silicone implants to increase the range of motion associated with them and the fatigue life of the silicone implants.


Sign in / Sign up

Export Citation Format

Share Document