Chemical amplification of the signal in ion-selective potentiometry: indirect determination of Al(III) and U(VI) by steady-state and flow-injection potentiometry using a copper ion-selective electrode

1992 ◽  
Vol 259 (1) ◽  
pp. 149-157 ◽  
Author(s):  
M. Neshkova ◽  
E. Pancheva ◽  
J. Fucsko ◽  
G. Nagy ◽  
E. Pungor
2016 ◽  
Vol 13 (2) ◽  
pp. 458-469
Author(s):  
Baghdad Science Journal

A simple, fast, selective of a new flow injection analysis method coupled with potentiometric detection was used to determine vitamin B1 in pharmaceutical formulations via the prepared new selective membranes. Two electrodes were constructed for the determination of vitamin B1 based on the ion-pair vitamin B1-phosphotungestic acid (B1-PTA) in a poly (vinyl chloride) supported with a plasticized di-butyl phthalate (DBPH) and di-butyl phosphate (DBP). Applications of these ion selective electrodes for the determination of vitamin B1 in the pharmaceutical preparations for batch and flow injection systems were described. The ion selective membrane exhibited a near-Nernstian slope values 56.88 and 58.53 mV / decade, with the linear dynamic range of vitamin B1 was 5 x 10-5- 1 x 10-2 and 1 x 10-4-1 x 10-2 mol.L-1, in batch and FIA, respectively. The limit of detection was 3.5 x 10-5 and 9.5 x 10-5 mol.L-1, with the percentage linearity 98.85 and 95.22 in batch and FIA, respectively. The suggested ion selective electrode has been utilized perfection in the determination of vitamin B1 in pharmaceutical formulations using batch and flow injection system, respectively.


2015 ◽  
Vol 12 (1) ◽  
pp. 188-196
Author(s):  
Baghdad Science Journal

A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .


1981 ◽  
Vol 46 (4) ◽  
pp. 982-986
Author(s):  
Dagmar Kalavská ◽  
Adam Košturiak ◽  
Svetozár Kalavský

A procedure of chelatometric determination of cobalt, nickel and lanthanoids based on back titration with Cu(II) ions using copper ion selective electrode has been developed and applied to alloys for novel type permanent magnets. In addition, a method has been worked out for direct titrimetric determination of lanthanoids with solution of fluoride ions in 75% ethanol using fluoride ion selective electrode.