A fiber optic probe for spectrophotometric determination of p(CO2) in sea water. Preliminary investigations

1988 ◽  
Vol 70 (1-2) ◽  
pp. 177
Author(s):  
J.P. Ciabrini ◽  
G. Michard ◽  
B. Brient
2000 ◽  
Vol 16 (5) ◽  
pp. 473-476 ◽  
Author(s):  
Xue-mei LIU ◽  
Wan-li XING ◽  
Guo-rong OU ◽  
Jun LIANG

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Jucelino Medeiros Marques Junior ◽  
Aline Lima Hermes Muller ◽  
Edson Luiz Foletto ◽  
Adilson Ben da Costa ◽  
Cezar Augusto Bizzi ◽  
...  

A method for determination of propranolol hydrochloride in pharmaceutical preparation using near infrared spectrometry with fiber optic probe (FTNIR/PROBE) and combined with chemometric methods was developed. Calibration models were developed using two variable selection models: interval partial least squares (iPLS) and synergy interval partial least squares (siPLS). The treatments based on the mean centered data and multiplicative scatter correction (MSC) were selected for models construction. A root mean square error of prediction (RMSEP) of 8.2 mg g−1was achieved using siPLS (s2i20PLS) algorithm with spectra divided into 20 intervals and combination of 2 intervals (8501 to 8801 and 5201 to 5501 cm−1). Results obtained by the proposed method were compared with those using the pharmacopoeia reference method and significant difference was not observed. Therefore, proposed method allowed a fast, precise, and accurate determination of propranolol hydrochloride in pharmaceutical preparations. Furthermore, it is possible to carry out on-line analysis of this active principle in pharmaceutical formulations with use of fiber optic probe.


Foods ◽  
2020 ◽  
Vol 9 (8) ◽  
pp. 968
Author(s):  
Ming Zhao ◽  
Saif Shaikh ◽  
Renxi Kang ◽  
Maria Markiewicz-Keszycka

This study investigated the use of Raman spectroscopy (RS) and chemometrics for the determination of eight mineral elements (i.e., Ca, Mg, K, Na, Cu, Mn, Fe, and Zn) in aqueous infant formula (INF). The samples were prepared using infant formula powder reconstituted to concentrations of 3%–13% w/w (powder: water) (n = 83). Raman spectral data acquisition was carried out using a non-contact fiber optic probe on the surface of aqueous samples in 50–3398 cm−1. ICP-AES was used as a reference method for the determination of the mineral contents in aqueous INF samples. Results showed that the best performing partial least squares regression (PLSR) models developed for the prediction of minerals using all samples for calibration achieved R2CV values of 0.51–0.95 with RMSECVs of 0.13–2.96 ppm. The PLSR models developed and validated using separate calibration (n = 42) and validation (n = 41) samples achieved R2CVs of 0.93, 0.94, 0.91, 0.90, 0.97, and 0.94, R2Ps of 0.75, 0.77, 0.31, 0.60, 0.84, and 0.80 with RMSEPs of 3.17, 0.29, 3.45, 1.51, 0.30, and 0.25 ppm for the prediction of Ca, Mg, K, Na, Fe, and Zn respectively. This study demonstrated that RS equipped with a non-contact fiber optic probe and combined with chemometrics has the potential for timely quantification of the mineral content of aqueous INF during manufacturing.


1995 ◽  
Vol 28 (3) ◽  
pp. 301-326 ◽  
Author(s):  
Guillermo A. Casay ◽  
Fred Meadows ◽  
Niambi Daniels ◽  
Alexandra Roberson ◽  
Gabor Patonay

2001 ◽  
Vol 40 (7) ◽  
pp. 1155 ◽  
Author(s):  
Jan S. Dam ◽  
Carsten B. Pedersen ◽  
Torben Dalgaard ◽  
Paul Erik Fabricius ◽  
Prakasa Aruna ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document