Enhancement of recombinant tissue plasminogen activator-induced reperfusion by recombinant tick anticoagulant peptide, a selective factor Xa inhibitor, in a canine model of femoral arterial thrombosis

1993 ◽  
Vol 7 (3) ◽  
pp. 195-202 ◽  
Author(s):  
M.J. Mellott ◽  
M.T. Stranieri ◽  
G.R. Sitko ◽  
I.I. Stabilito ◽  
J.J. Lynch ◽  
...  
1991 ◽  
Vol 71 (4) ◽  
pp. 1441-1446 ◽  
Author(s):  
R. M. Prewitt ◽  
S. A. Gu ◽  
D. Greenberg ◽  
S. M. Chan ◽  
U. Schick ◽  
...  

We employed a canine model of pulmonary embolism induced by injection of radioactive blood clots to investigate effects of changes in cardiac output (CO) on recombinant tissue plasminogen activator- (rtPA) induced pulmonary thrombolysis. Rate and extent of thrombolysis were assessed with a gamma camera. Eighteen dogs were studied. Emboli increased mean pulmonary arterial pressure and decreased CO from 2.6 to 1.9 l/min (P less than 0.001). Subsequently, dogs were randomly divided into three groups: group 1 received 0.5 mg/kg of rtPA over 30 min; 30 min before the same dose regimen of rtPA, in the six group 2 dogs, mean CO was increased to approximately 3.25 l/min by opening one systemic arteriovenous fistula; in the six group 3 dogs, before rtPA, mean CO was increased to approximately 4.5 l/min by opening two or three fistulas. After embolization, CO remained low in group 1; the mean 2-h time-averaged CO was 1.8 l/min. CO was much higher in groups 2 and 3 (3.3 and 4.6 l/min, respectively; both P less than 0.001 compared with group 1; and P less than 0.001, group 2 vs. group 3). Compared with group 1, corresponding to the increased flow in groups 2 and 3, rate and extent of pulmonary thrombolysis significantly increased. These results indicate that an increase in flow per se augments rtPA-induced pulmonary thrombolysis. Also, because thrombolysis was similar between groups 2 and 3, these results define an upper limit to the flow-thrombolytic relationship with rtPA.


1988 ◽  
Vol 60 (01) ◽  
pp. 107-112 ◽  
Author(s):  
Roy Harris ◽  
Louis Garcia Frade ◽  
Lesley J Creighton ◽  
Paul S Gascoine ◽  
Maher M Alexandroni ◽  
...  

SummaryThe catabolism of recombinant tissue plasminogen activator (rt-PA) was investigated after injection of radiolabelled material into rats. Both Iodogen and Chloramine T iodination procedures yielded similar biological activity loss in the resultant labelled rt-PA and had half lives in the rat circulation of 1 and 3 min respectively. Complex formation of rt-PA was investigated by HPLC gel exclusion (TSK G3000 SW) fractionation of rat plasma samples taken 1-2 min after 125I-rt-PA injection. A series of radiolabelled complexes of varying molecular weights were found. However, 60% of the counts were associated with a single large molecular weight complex (350–500 kDa) which was undetectable by immunologically based assays (ELISA and BIA) and showed only low activity with a functional promoter-type t-PA assay. Two major activity peaks in the HPLC fractions were associated with Tree t-PA and a complex having a molecular weight of ̴ 180 kDa. HPLC fractionation to produce these three peaks at various timed intervals after injection of 125I-rt-PA showed each to have a similar initial rate half life in the rat circulation of 4-5 min. The function of these complexes as yet is unclear but since a high proportion of rt-PA is associated with a high molecular weight complex with a short half life in the rat, we suggest that the formation of this complex may be a mechanism by which t-PA activity is initially regulated and finally cleared from the rat circulation.


Sign in / Sign up

Export Citation Format

Share Document