Isotachophoretic determination of lactate ions in vitreous humour samples and its use in forensic toxicology

1990 ◽  
Vol 44 (2-3) ◽  
pp. 273-280 ◽  
Author(s):  
D.R. Harper
2019 ◽  
Vol 26 (1) ◽  
pp. 177-196 ◽  
Author(s):  
Mateusz Kacper Woźniak ◽  
Marek Wiergowski ◽  
Jacek Namieśnik ◽  
Marek Biziuk

Background:Ethyl alcohol is the most popular legal drug, but its excessive consumption causes social problems. Despite many public campaigns against alcohol use, car accidents, instances of aggressive behaviour, sexual assaults and deterioration in labor productivity caused by inebriated people is still commonplace. Fast and easy diagnosis of alcohol consumption is required in order to introduce proper and effective therapy, and is crucial in forensic toxicology analysis. The easiest method to prove alcohol intake is determination of ethanol in body fluids or in breath. However, since ethanol is rapidly metabolized in the human organism, only recent consumption can be detected using this method. Because of that, the determination of alcohol biomarkers was introduced for monitoring alcohol consumption over a wider range of time.Objective:The objective of this study was to review published studies focusing on the sample preparation methods and chromatographic or biochemical techniques for the determination of alcohol biomarkers in whole blood, plasma, serum and urine.Methods:An electronic literature search was performed to discuss possibilities and limitations of application of alcohol biomarkers in toxicological analysis.Results:Authors described the markers of alcohol consumption such as: ethanol, its nonoxidative metabolites (ethyl glucuronide, ethyl sulfate, phosphatidylethanol, ethyl phosphate, fatty acid ethyl esters) and oxidative metabolites (acetaldehyde and acetaldehyde adducts). We also discussed issues concerning the detection window of these biomarkers, and possibilities and limitations of their use in routine analytical toxicology for monitoring alcohol consumption or sobriety during alcohol therapy.


2020 ◽  
Vol 16 (7) ◽  
pp. 872-879
Author(s):  
Samin Hamidi

Background: Abuse of drugs is associated with several medical, forensic, toxicology and social challenges. “Drugs of abuse” testing is therefore an important issue. Objective: We propose a simple CE-based method for the quantification of amphetamine, codeine and morphine after direct injection of Exhaled Breath Condensate (EBC) by the aid of simple stacking mode and an off-line pre-concentration method. Methods: Using graphene oxide adsorbents, amphetamine, codeine and morphine were extracted from EBC in order to eliminate the proteins and other interferences. In addition to off-line method, an online stacking mode was applied to improve the analytical signal obtained from the instrument. Results: The validation parameters were experimented on the developed method based on the FDA guideline over concentration ranges of 12.5-100, 30-500 and 10-1250 ng/mL associated with amphetamine, codeine and morphine, respectively. Small volumes (around 100 μL) of EBC were collected using a lab-made setup and successfully analyzed using the proposed method where precisions and accuracies (within day and between days) were in accordance with the guideline (recommended less than 15 % for biological samples). The recovery tests were used to evaluate the matrix effect and data (94 to 105 %) showed that the proposed method can be applied in different EBC matrix samplings of subjects. Conclusion: The proposed method is superior for simultaneous determination of amphetamine, codeine and morphine over chromatographic analyses because it is fast and consumes fewer chemicals, with no derivatization step.


2011 ◽  
Vol 49 (10) ◽  
pp. 745-752 ◽  
Author(s):  
B. Puente ◽  
M. A. Garcia ◽  
E. Hernandez ◽  
M. A. Bregante ◽  
S. Perez ◽  
...  

2005 ◽  
Vol 24 (4) ◽  
pp. 275-281 ◽  
Author(s):  
Vassiliki A. Boumba ◽  
Theodore Vougiouklakis

Numerous methods have been described in the literature for the determination of carboxyhemoglobin (COHb) in whole blood. The most popular and widely used have been (1) the spectrophotometric methods, which could be performed either by using a conventional spectrophotometer or by using specialized automated instruments known as CO-oximeters; (2) the gas chromatographic methods, with variable detection systems, which have been considered as the reference methods for every carbon monoxide analysis. The authors have critically reviewed previously reported comparative studies on these methods, considering statistical and analytical matters, in order to propose the best method for the determination of COHb in postmortem blood, that could be utilized in forensic toxicology laboratories where such analyses are limited in number (less than 20 per year). Criteria for evaluation have been accuracy, reliability, simplicity, time, and cost. The authors’ concluding statement has been that the manual spectrophotometric method could be the method of choice for COHb determination in postmortem blood samples. It is simple, rapid, and reliable and fulfills the forensically acceptable accuracy. It is performed by the use of a conventional spectrophotometer, which is considered a basic instrument in every analytical laboratory.


2004 ◽  
Vol 23 (12) ◽  
pp. 571-577 ◽  
Author(s):  
H M Teixeira ◽  
F Reis ◽  
P Proença ◽  
P Ramos ◽  
O Quińtela ◽  
...  

The quantification of medical or toxic substances in vitreous humour (VH) could be very useful in forensic toxicology when blood sample determinations are impossible due to absence or deterioration. However, few studies have been made in this area and even fewer have tried to find a relationship between drug levels in both samples. To determine a correlation ratio between blood and VH diazepam (DZ) levels, we performed an experimental study using rabbits administered with a sub-toxic dose of DZ under known and controlled conditions. Blood and VH samples were collected 0.5, 1, 2, 3 and 6 hours after the drug administration in order to determine DZ and its main active metabolite, desmethyldiazepam (DMD). In addition, we have studied an animal group sacrificed 2 hours after intramuscular (i.m.) drug administration with blood and VH collection 24 hours later, to evaluate the existence of possible post-mortem changes. After DZ administration, a fast absorption phase was observed with a plasma Cmax value 1 hour after, followed by a rapid concentration decrease, with a half-life of 1 hour, indicating that, besides elimination, a fast distribution to other organs and tissues and/or hepatic metabolism occurred. Diazepam Cmax value in VH was achieved between 1 and 2 hours, when plasma concentrations had already decreased to half the value. The plasma/VH DZ ratio calculated at this time was 10. In the post-mortem study, while plasma DZ concentration at 24 hours was smaller, DMD levels were higher than those at the time of death. In the VH, both DZ and DMD concentrations at 24 hours were higher than those obtained at the time of death. That is, in both fluids DZ and DMD concentrations were different from those at the time of death and post-mortem distribution and redistribution phenomena occurred. The combination of antemortem and post-mortem studies has allowed the determination of a correlation ratio for DZ in the rabbit of 6×, comparing the concentrations in VH collected 24 hours after death with the concentrations detected in plasma at the time of death. This study opens new perspectives for the use of VH as a complementary sample to blood for DZ detection and confirmation. The putative relevance of the correlation ratio obtained, for forensic toxicology practice with medical substances, namely benzodiazepines, recommends further studies in humans.


1997 ◽  
Vol 18 (2) ◽  
pp. 158-162 ◽  
Author(s):  
Ross A. James ◽  
Paul A. Hoadley ◽  
Brett G. Sampson

1990 ◽  
Vol 42 (S1) ◽  
pp. 109P-109P
Author(s):  
P. Zhou ◽  
J. M. Midgley ◽  
R. G. Macfarlane ◽  
D. G. Watson ◽  
S. C. Macfarlane ◽  
...  
Keyword(s):  

2001 ◽  
Vol 121 (1-2) ◽  
pp. 116-125 ◽  
Author(s):  
Eric Lacassie ◽  
Pierre Marquet ◽  
Jean-Michel Gaulier ◽  
Marie-Françoise Dreyfuss ◽  
Gérard Lachâtre

Sign in / Sign up

Export Citation Format

Share Document