Understanding and Selecting Prosthetic Feet

Author(s):  
Kevin Carroll ◽  
John Rheinstein ◽  
Elicia Pollard
Keyword(s):  
2018 ◽  
Vol 62 ◽  
pp. 349-354 ◽  
Author(s):  
Cody L. McDonald ◽  
Patricia A. Kramer ◽  
Sara J. Morgan ◽  
Elizabeth G. Halsne ◽  
Sarah M. Cheever ◽  
...  

2012 ◽  
Vol 36 (2) ◽  
pp. 203-216 ◽  
Author(s):  
Edward Schreiber Neumann ◽  
Kartheek Yalamanchili ◽  
Justin Brink ◽  
Joon S Lee

Background: Knowledge of transtibial residual limb force and moment loading during gait can be clinically useful. The research question was whether a transducer attached between the socket and pylon can be used to detect differences in loading patterns created by prosthetic feet of different design and different walking activities in real-world environments outside the gait lab. Objectives: To develop methods for obtaining, processing, analyzing and interpreting transducer measurements and examining their clinical usefulness. Study Design: Case series design. Methods: A convenience sample of four K3-K4 transtibial amputees and a wireless tri-axial transducer mounted distal to the socket. Activities included self-selected comfortable speed walking, and ascending and descending ramps and steps. Measurements taken about three orthogonal axes were processed to produce plots of normalized resultant force versus normalized resultant moment. Within-subject differences in peak resultant forces and moments were tested. Results: Loading patterns between feet and subjects and among the activities were distinctly different. Optimal loading of peak resultant forces tentatively might occur around 25% and 69% to73% of stance during self-selected comfortable walking. Ascending and descending ramps is useful for examining heel and forefoot response. Conclusions: Force-moment plots obtained from transducer data may assist clinical decision making. Clinical relevance A pylon-mounted transducer distal to the socket reveals the moments and forces transmitted to the residual limb and can be used to evaluate the loading patterns on the residual limb associated with different foot designs and different everyday activities outside the gait lab.


2021 ◽  
Author(s):  
Victor Prost ◽  
W. Brett Johnson ◽  
Jenny A. Kent ◽  
Matthew J. Major ◽  
Amos G. Winter

Abstract The walking pattern and comfort of a person with lower limb amputation are determined by the prosthetic foot’s diverse set of mechanical characteristics. However, most design methodologies are iterative and focus on individual parameters, preventing a holistic design of prosthetic feet for a user’s body size and walking preferences. Here we refined and evaluated the lower leg trajectory error (LLTE) framework, a novel quantitative and predictive design methodology that optimizes the mechanical function of a user’s prosthesis to encourage gait dynamics that match their body size and desired walking pattern. Five people with unilateral below-knee amputation walked over-ground at self-selected speeds using an LLTE-optimized foot made of Nylon 6/6, their daily-use foot, and a standardized commercial energy storage and return (ESR) foot. Using the LLTE feet, target able-bodied kinematics and kinetics were replicated to within 5.2% and 13.9%, respectively, 13.5% closer than with the commercial ESR foot. Additionally, energy return and center of mass propulsion work were 46% and 34% greater compared to the other two prostheses, which could lead to reduced walking effort. Similarly, peak limb loading and flexion moment on the intact leg were reduced by an average of 13.1%, lowering risk of long-term injuries. LLTE-feet were preferred over the commercial ESR foot across all users and preferred over the daily-use feet by two participants. These results suggest that the LLTE framework could be used to design customized, high performance ESR prostheses using low-cost Nylon 6/6 material.


2017 ◽  
Vol 42 ◽  
pp. 47-54 ◽  
Author(s):  
Paolo Taboga ◽  
Alena M. Grabowski

Sign in / Sign up

Export Citation Format

Share Document