Mechanical Alignment Total Knee Arthroplasty: A Thoughtful Beginning With Unanticipated Limitations

2022 ◽  
pp. 1-5
Author(s):  
Richard F. Santore
Author(s):  
Pablo Besa ◽  
Rafael Vega ◽  
Gerardo Ledermann ◽  
Claudio Calvo ◽  
Manuela Angulo ◽  
...  

AbstractThis study aimed to determine the tibial cut (TC) accuracy using extensor hallucis longus (EHL) tendon as an anatomical landmark to position the total knee arthroplasty (TKA) extramedullary tibial guide (EMTG), and its impact on the TKA mechanical alignment (MA). We retrospectively studied 96 TKA, performed by a single surgeon, using a femoral tailored intramedullary guide technique. Seventeen were prior to the use of the EHL and 79 used the EHL tendon to position the EMTG. We analyzed preoperative and postoperative standing total lower extremity radiographs to determine the tibial component angle (TCA) and the correction in MA, comparing pre-EHL use and post-EHL technique incorporation. Mean TCA was 88.89 degrees and postoperative MA was neutral in 81% of patients. Pre- and postoperative MAs were not correlated. As a conclusion of this study, using the EHL provides a safe and easy way to determine the position of EMTG.


2015 ◽  
Vol 2015 ◽  
pp. 1-3 ◽  
Author(s):  
Dongquan Shi ◽  
Xingquan Xu ◽  
Anyun Guo ◽  
Jin Dai ◽  
Zhihong Xu ◽  
...  

Introduction. Mechanical alignment deviation after total knee arthroplasty is a major reason for early loosening of the prosthesis. Achieving optimum cement penetration during fixation of the femoral and tibial component is an essential step in performing a successful total knee arthroplasty. Bone cement is used to solidify the bone and prosthesis. Thickness imbalance of bone cement leads to the deviation of mechanical alignment. To estimate the influence of bone cement, a retrospective study was conducted.Materials and Methods. A total of 36 subjects were studied. All the TKA were performed following the standard surgical protocol for navigated surgery by medial approach with general anaesthesia. Prostheses were fixed by bone cement.Results. We compared the mechanical axis, flexion/extension, and gap balance before and after cementation. All the factors were different compared with those before and after cementation. Internal rotation was reached with statistical significance (P=0.03).Conclusion. Bone cement can influence the mechanical axis, flexion/extension, and gap balance. It also can prompt us to make a change when poor knee kinematics were detected before cementation.


2019 ◽  
Vol 95 (1121) ◽  
pp. 125-133 ◽  
Author(s):  
Yi Ren ◽  
Shiliang Cao ◽  
Jinxuan Wu ◽  
Xisheng Weng ◽  
Bin Feng

BackgroundIn the field of prosthetics, the ultimate goal is to improve the clinical outcome by using a technique that prolongs the longevity of prosthesis. Active robotic-assisted total knee arthroplasty (TKA) is one such technique that is capable of providing accurate implant position and restoring mechanical alignment. Although relevant studies have been carried out, the differences in the efficacy and reliability between active robotic-assisted TKA and conventional arthroplasty have not yet been adequately discussed.MethodsWe referenced articles, including randomised controlled trials and comparative retrospective research, from PubMed, Embase, Cochrane Library and Web of Science, in order to compare active robotic-assisted TKA with the conventional technique. Data extraction and quality assessment were conducted for each study. Statistical analysis was performed using Revman V. 5.3.ResultsSeven studies with a total of 517 knees undergoing TKA were included. Compared with conventional surgery, active robotic TKA showed better outcomes in precise mechanical alignment (mean difference, MD: − 0.82, 95% CI: −1.15 to − 0.49, p < 0.05) and implant position, with lower outliers (p < 0.05), better functional score (Western Ontario and McMaster University, Knee Society Score functional score) and less drainage (MD: − 293.28, 95% CI: − 417.77 to − 168.79, p < 0.05). No significant differences were observed when comparing the operation time, range of motion and complication rates.ConclusionThe current research demonstrates that active robotic-assisted TKA surgeries are more capable of improving mechanical alignment and prosthesis implantation when compared with conventional surgery. Further studies are required to investigate the potential benefits and long-term clinical outcomes of active robotic-assisted TKA.


2016 ◽  
Vol 10 (1) ◽  
pp. 357-363 ◽  
Author(s):  
Panagiota Toliopoulos ◽  
Marc-Andre LeBlanc ◽  
Jonathan Hutt ◽  
Martin Lavigne ◽  
Francois Desmeules ◽  
...  

Objectives:The purpose of this study was to compare the intra-operative benefits and the clinical outcomes from kinematic or mechanical alignment for total knee arthroplasty (TKA) in patients undergoing revision of failed unicompartmental kneel arthroplasty (UKA) to TKA.Methods:Ten revisions were performed with a kinematic alignment technique and 11 with a mechanical alignment. Measurements of the hip-knee-ankle angle (HKA), the lateral distal femoral angle (LDFA), and the medial proximal tibial angle (MPTA) were performed using long-leg radiographs. The need for augments, stems, and constrained inserts was compared between groups. Clinical outcomes were compared using the WOMAC score along with maximum distance walked as well as knee range of motion obtained prior to discharge. All data was obtained by a retrospective review of patient files.Results:The kinematic group required less augments, stems, and constrained inserts than the mechanical group and thinner polyethylene bearings. There were significant differences in the lateral distal femoral angle (LDFA) and the medial proximal tibial angle (MPTA) between the two groups (p<0.05). The mean WOMAC score obtained at discharge was better in the kinematic group as was mean knee flexion. At last follow up of 34 months for the kinematic group and 58 months for the mechanical group, no orthopedic complications or reoperations were recorded.Conclusion:Although this study has a small patient cohort, our results suggest that kinematic alignment for TKA after UKA revision is an attractive method. Further studies are warranted.


2020 ◽  
Author(s):  
Jiaxiang Gao ◽  
Yunfei Hou ◽  
Zhichang Li ◽  
Runjun Li ◽  
Yan Ke ◽  
...  

Abstract Background: This study aimed to determine whether the iAssist navigation system (NAV) could improve the accuracy of restoring mechanical axis (MA), component positioning, and clinical outcomes compared to conventional (CON) total knee arthroplasty (TKA). Methods: A total of 301 consecutive patients (NAV: 27, CON: 274) were included. A 1:4 propensity score matching (PSM) was performed between the two groups according to preoperative demographic and clinical parameters. The postoperative MA, femoral coronal angle (FCA), femoral sagittal angle (FSA), tibial coronal angle (TCA) and tibial sagittal angle (TSA) were compared. Absolute deviations of aforementioned angles were calculated as the absolute value of difference between the exact and ideal value and defined as appropriate if within 3°, otherwise regarded as outliers. Additional clinical parameters, including the Knee Society knee and function scores (KSKS and KSFS) and range of motion (ROM), were assessed at the final follow-up (mean follow-up time was 21.88 and 21.56 months respectively for NAV and CON group). Results: A total of 98 patients/102 knees were analyzed after the PSM (NAV: 21 patients/24 knees, CON: 77 patients/78 knees). In the NAV group, the mean MA, FCA and TSA were significantly improved (p = 0.019, 0.006, <0.001, respectively). Proportions of TKAs within a ±3°deviation were significantly improved in all the postoperative radiological variables except for TCA (p = 0.003, 0.021, 0,017, 0.013, respectively for MA, FCA, FSA, and TSA). The absolute deviations of FSA and TSA were also significantly lower in the NAV group (p = 0.016, 0.048, respectively). In particular, no significant differences were found in either mean value, absolute deviation or outlier ratio of TCA between two groups. For the clinical outcomes, there were no significant differences between two groups, although KSKS, KSFS and ROM (p<0.01, respectively) dramatically improved compared to baseline. Conclusions: We suggested that the iAssist system could improve the accuracy and precision of mechanical alignment and component positioning without significant improvement of clinical outcomes. Further long-term high-quality studies are necessary to validate the results.


Sign in / Sign up

Export Citation Format

Share Document