Development of a real-time PCR assay for Trypanosoma cruzi detection in blood samples

Acta Tropica ◽  
2007 ◽  
Vol 103 (3) ◽  
pp. 195-200 ◽  
Author(s):  
Maria Piron ◽  
Roser Fisa ◽  
Natalia Casamitjana ◽  
Paulo López-Chejade ◽  
Lluís Puig ◽  
...  
2010 ◽  
Vol 4 (08) ◽  
pp. 511-516 ◽  
Author(s):  
Parisa Badiee ◽  
Abdolvahab Alborzi

Introduction:  Invasive aspergillosis is a severe complication of cytotoxic chemotherapies and bone marrow transplantation (BMT). The aim of this study was to assess the utility of a real-time PCR assay for the early diagnosis of Aspergillus species in blood samples from BMT patients. Methodology: Blood specimens (n = 993) from patients (n = 82) scheduled for BMT were collected prior to transplant and for 100 days post transplantation.  The specimens were later tested using an Aspergillus-specific real-time PCR assay. Cultures of clinical samples, along with sonography and computerized tomographic scans, were performed as standard of care. Results: Aspergillus DNA was positive in 94 sequential blood samples from 13 patients with clinical and radiological signs of infection. Samples from three of these patients were PCR-positive for Aspergillus in the first week of admission, prior to transplantation. Four patients with aspergillosis were cured with antifungal agents and nine died. An additional 12 patients without clinical signs of infection were PCR-positive on one occasion each, while two patients with clinical signs of infection were PCR-negative. Compared to routine methods of aspergillosis diagnosis, the respective sensitivity, specificity, negative, and positive predictive values of the PCR method by patient were 86.6%, 82%, 96.5% and 52%. Conclusions: The results show that Aspergillus infections in the blood of bone marrow transplant patients can be dectected by PCR methods. Early detection of Aspergillus infections by PCR has the potential to positively impact patient mortality rate and provide cost savings to hospitals.


2021 ◽  
Author(s):  
Mahlet Belachew ◽  
Mistire Wolde ◽  
Desalegn Nega ◽  
Bokretsion Gidey ◽  
Legessie Negash ◽  
...  

Abstract Background: Malaria incidence has declined in Ethiopia in the past ten years. Current malaria diagnostic tests, including light microscopy and antigen-detecting rapid tests (RDTs) cannot reliably detect low-density infections. Studies have shown that nucleic acid amplification tests are highly sensitive and specific in detecting malaria infection. Thus, this study took place with the aim of evaluating the performance of multiplex real time PCR for the diagnosis of malaria using patient samples collected from health facilities located at malaria elimination targeted low transmission settings in Ethiopia. Methods: A health facility based cross sectional survey was conducted in selected malaria sentinel sites. Malaria suspected febrile outpatients referred to laboratory for malaria testing between December 2019 and March 2020 were enrolled into this study. Socio demographic information and capillary blood samples were collected from the study participants and tested at spot with RDTs. Additionally, five circles of dry blood sample (DBS) samples on Whatman filter paper and thick and thin smear were prepared for molecular testing and microscopic examination, respectively. Multiplex real time PCR assay was performed at EPHI malaria laboratory. The performance of multiplex real time PCR assay, microscopy and RDT for the diagnosis of malaria was compared and evaluated against each other.Results: Out of 271 blood samples, multiplex real time PCR identified 69 malaria cases as P. falciparum infection, 16 as P. vivax and 3 as mixed infections. Of the total samples, light microscopy detected 33 as Pf, 18 as PV and RDT detected 43 as Pf, 17 as PV, and one mixed infection. Using light microscopy as reference test, the sensitivity and specificity of multiplex real time PCR were 100% (95% CI [93-100]) and 83.2% (95% CI [77.6-87.9]), respectively. Using multiplex real time PCR as a reference, light microscopy and RDT had sensitivity of 58% (95% CI [46.9-68.4] and 67% (95% CI [56.2-76.7]); and 100% (95% CI [98-100] and 98.9 (95% CI (96-99.9), respectively. Substantial level of agreement was reported between microscopy and multiplex real time PCR results with kappa value of 0.65. Conclusions: Multiplex real time PCR had an advanced performance in parasite detection and species identification on febrile patients’ samples than did microscopy and RDT in low malaria transmission settings. It is highly sensitive malaria diagnostic method that can be used in malaria elimination program, particularly for community based epidemiological samples. Although microscopy and RDT had reduced performance when compared to multiplex real time PCR, still had an acceptable performance in diagnosis of malaria cases on patient samples at clinical facilities.


2015 ◽  
Vol 9 (5) ◽  
pp. e0003765 ◽  
Author(s):  
Carolina I. Cura ◽  
Tomas Duffy ◽  
Raúl H. Lucero ◽  
Margarita Bisio ◽  
Julie Péneau ◽  
...  

2006 ◽  
Vol 36 ◽  
pp. S26
Author(s):  
C. Deback ◽  
S. Akhavan ◽  
S. Blanc-Perrel ◽  
F. Dupuis ◽  
S. Schaffer ◽  
...  

2007 ◽  
Vol 197 (3) ◽  
pp. 313-324 ◽  
Author(s):  
Lutz Eric Lehmann ◽  
Klaus-Peter Hunfeld ◽  
Thomas Emrich ◽  
Gerd Haberhausen ◽  
Heimo Wissing ◽  
...  

2022 ◽  
Vol 21 (1) ◽  
Author(s):  
Mahlet Belachew ◽  
Mistire Wolde ◽  
Desalegn Nega ◽  
Bokretsion Gidey ◽  
Legessie Negash ◽  
...  

Abstract Background Malaria incidence has declined in Ethiopia in the past 10 years. Current malaria diagnostic tests, including light microscopy and rapid antigen-detecting diagnostic tests (RDTs) cannot reliably detect low-density infections. Studies have shown that nucleic acid amplification tests are highly sensitive and specific in detecting malaria infection. This study took place with the aim of evaluating the performance of multiplex real time PCR for the diagnosis of malaria using patient samples collected from health facilities located at malaria elimination targeted low transmission settings in Ethiopia. Methods A health facility-based, cross-sectional survey was conducted in selected malaria sentinel sites. Malaria-suspected febrile outpatients referred to laboratory for malaria testing between December 2019 and March 2020 was enrolled into this study. Sociodemographic information and capillary blood samples were collected from the study participants and tested at spot with RDTs. Additionally, five circles of dry blood spot (DBS) samples on Whatman filter paper and thick and thin smear were prepared for molecular testing and microscopic examination, respectively. Multiplex real time PCR assay was performed at Ethiopian Public Health Institute (EPHI) malaria laboratory. The performance of multiplex real time PCR assay, microscopy and RDT for the diagnosis of malaria was compared and evaluated against each other. Results Out of 271 blood samples, multiplex real time PCR identified 69 malaria cases as Plasmodium falciparum infection, 16 as Plasmodium vivax and 3 as mixed infections. Of the total samples, light microscopy detected 33 as P. falciparum, 18 as P. vivax, and RDT detected 43 as P. falciparum, 17 as P. vivax, and one mixed infection. Using light microscopy as reference test, the sensitivity and specificity of multiplex real time PCR were 100% (95% CI (93–100)) and 83.2% (95% CI (77.6–87.9)), respectively. Using multiplex real time PCR as a reference, light microscopy and RDT had sensitivity of 58% (95% CI 46.9–68.4) and 67% (95% CI 56.2–76.7); and 100% (95% CI 98–100) and 98.9% (95% CI 96–99.9), respectively. Substantial level of agreement was reported between microscopy and multiplex real time PCR results with kappa value of 0.65. Conclusions Multiplex real-time PCR had an advanced performance in parasite detection and species identification on febrile patients’ samples than did microscopy and RDT in low malaria transmission settings. It is highly sensitive malaria diagnostic method that can be used in malaria elimination programme, particularly for community based epidemiological samples. Although microscopy and RDT had reduced performance when compared to multiplex real time PCR, still had an acceptable performance in diagnosis of malaria cases on patient samples at clinical facilities.


2017 ◽  
Vol 31 ◽  
pp. 65-69 ◽  
Author(s):  
Filipe Dantas-Torres ◽  
Kamila Gaudêncio da Silva Sales ◽  
Lidiane Gomes da Silva ◽  
Domenico Otranto ◽  
Luciana Aguiar Figueredo

Sign in / Sign up

Export Citation Format

Share Document