diagnostic tests
Recently Published Documents


TOTAL DOCUMENTS

5711
(FIVE YEARS 1490)

H-INDEX

118
(FIVE YEARS 15)

2022 ◽  
Vol 28 (2) ◽  
Author(s):  
Daniel Mukadi-Bamuleka ◽  
Yibayiri Osee Sanogo ◽  
Junior Bulabula-Penge ◽  
Maria E. Morales-Betoulle ◽  
Patrice Fillon ◽  
...  

2022 ◽  
Author(s):  
Cynthia Hopf-Dennis ◽  
Sarrah Kaye ◽  
Nicholas Hollingshead ◽  
Marjory Brooks ◽  
Elizabeth Bunting ◽  
...  

Abstract Anticoagulant rodenticides (ARs) continue to be used across the United States as a method for controlling unwanted rodent species. As a consequence, wild birds of prey are exposed to toxins by eating poisoned prey items. ARs prevent the hepatic recycling of vitamin K and thereby impede the post-translational processing of coagulation factors II, VII, IX, and X that is required for procoagulant complex assembly. Through this mechanism of action, ARs cause hemorrhage and death in their target species. Various studies have documented the persistence of these contaminants in birds of prey but few have attempted to use affordable and accessible diagnostic tests to diagnose exposure in free-ranging birds of prey. In our study free-ranging red-tailed hawks were found to be exposed to difethialone and brodifacoum. Eleven of sixteen (68%) livers tested for AR exposure were positive. Difethialone was found in 1/16 (6%) liver samples, and brodifacoum was detected in 15/16 (93%) liver samples. Difethialone was found at a concentration of 0.18 ppm and brodifacoum concentrations ranged from 0.003-0.234 ppm. Two out of 34 (6%) RTH assessed for blood rodenticide had brodifacoum in blood with measured concentrations of 0.003 and 0.006 ppm. The range of clotting times in the prothrombin time (PT) and Russell’s viper venom time assays for control RTH were 16.7 to 39.7 seconds and 11.5 to 91.8 seconds, respectively. No correlation was found between PT and RVVT in the control or free-range RTH, and there was no relationship found between the presence of liver anticoagulant residues and clotting times in the PT and RVVT.


2022 ◽  
Vol 10 (1) ◽  
pp. 172
Author(s):  
Bruna De Lucca Caetano ◽  
Marta de Oliveira Domingos ◽  
Miriam Aparecida da Silva ◽  
Jessika Cristina Alves da Silva ◽  
Juliana Moutinho Polatto ◽  
...  

The secretion of α-hemolysin by uropathogenic Escherichia coli (UPEC) is commonly associated with the severity of urinary tract infections, which makes it a predictor of poor prognosis among patients. Accordingly, this toxin has become a target for diagnostic tests and therapeutic interventions. However, there are several obstacles associated with the process of α-hemolysin purification, therefore limiting its utilization in scientific investigations. In order to overcome the problems associated with α-hemolysin expression, after in silico prediction, a 20.48 kDa soluble α-hemolysin recombinant denoted rHlyA was constructed. This recombinant is composed by a 182 amino acid sequence localized in the aa542–723 region of the toxin molecule. The antigenic determinants of the rHlyA were estimated by bioinformatics analysis taking into consideration the tertiary form of the toxin, epitope analysis tools, and solubility inference. The results indicated that rHlyA has three antigenic domains localized in the aa555–565, aa600–610, and aa674–717 regions. Functional investigation of rHlyA demonstrated that it has hemolytic activity against sheep red cells, but no cytotoxic effect against epithelial bladder cells. In summary, the results obtained in this study indicate that rHlyA is a soluble recombinant protein that can be used as a tool in studies that aim to understand the mechanisms involved in the hemolytic and cytotoxic activities of α-hemolysin produced by UPEC. In addition, rHlyA can be applied to generate monoclonal and/or polyclonal antibodies that can be utilized in the development of diagnostic tests and therapeutic interventions.


2022 ◽  
Vol 21 (1) ◽  
Author(s):  
Rachel Wittenauer ◽  
Spike Nowak ◽  
Nick Luter

Abstract Background Rapid diagnostic tests (RDTs) for malaria are a vital part of global malaria control. Over the past decade, RDT prices have declined, and quality has improved. However, the relationship between price and product quality and their larger implications on the market have yet to be characterized. This analysis used purchase data from the Global Fund together with product quality data from the World Health Organization (WHO) and Foundation for Innovative New Diagnostics (FIND) Malaria RDT Product Testing Programme to understand three unanswered questions: (1) Has the market share by quality of RDTs in the Global Fund’s procurement orders changed over time? (2) What is the relationship between unit price and RDT quality? (3) Has the market for RDTs financed by the Global Fund become more concentrated over time? Methods Data from 10,075 procurement transactions in the Global Fund’s database, which includes year, product, volume, and price, was merged with product quality data from all eight rounds of the WHO-FIND programme, which evaluated 227 unique RDT products. To describe trends in market share by quality level of RDT, descriptive statistics were used to analyse trends in market share from 2009 to 2018. A generalized linear regression model was then applied to characterize the relationship between price and panel detection score (PDS), adjusting for order volume, year purchased, product type, and manufacturer. Third, a Herfindahl–Hirschman Index (HHI) score was calculated to characterize the degree of market concentration. Results Lower-quality RDTs have lost market share between 2009 and 2018, as have the highest-quality RDTs. No statistically significant relationship between price per test and PDS was found when adjusting for order volume, product type, and year of purchase. The HHI was 3,570, indicating a highly concentrated market. Conclusions Advancements in RDT affordability, quality, and access over the past decade risk stagnation if health of the RDT market as a whole is neglected. These results suggest that from 2009 to 2018, this market was highly concentrated and that quality was not a distinguishing feature between RDTs. This information adds to previous reports noting concerns about the long-term sustainability of this market. Further research is needed to understand the causes and implications of these trends.


2022 ◽  
Author(s):  
Yusaku Akashi ◽  
Michiko Horie ◽  
Junichi Kiyotaki ◽  
Yuto Takeuchi ◽  
Kenichi Togashi ◽  
...  

Background and Objective: Point-of-care type molecular diagnostic tests have been used for detecting SARS-CoV-2, although their clinical utility with nasal samples has yet to be established. This study evaluated the clinical performance of the cobas Liat SARS-CoV-2 & Influenza AB (Liat) in nasal samples. Methods: Nasal and nasopharyngeal samples were collected and were tested using the Liat, the cobas 6800 system and the cobas SARS-CoV-2 & Influenza AB (cobas), and a method developed by National Institute of Infectious Diseases, Japan (NIID). Results: A total of 814 nasal samples were collected. The Liat assay was positive for SARS-CoV-2 in 113 (13.9%). The total, positive, and negative concordance rate between the Liat and cobas/NIID assays were 99.3%/98.4%, 99.1%/100%, and 99.3%/98.2%, respectively. Five samples were positive only using the Liat assay. Their Ct values ranged from 31.9 to 37.2. The Ct values of the Liat assay were significantly lower (p < 0.001) but were correlated (p < 0.001) with those of other molecular assays. In the participants who tested positive for SARS-CoV-2 on the Liat assay using nasopharyngeal samples, 88.2% of their nasal samples also tested positive using the Liat assay. Conclusion: The Liat assay showed high concordance with other molecular assays in nasal samples. Some discordance occurred in samples with Ct values > 30 on the Liat assay.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 131
Author(s):  
Kaoru Murakami ◽  
Ian Pagano ◽  
Hideki Furuya ◽  
Timothy Daskivich ◽  
Dave Mori ◽  
...  

Oncuria™ is a validated quantitative multiplex immunoassay capable of detecting bladder cancer from a voided urine sample. Herein, we sought to determine whether Oncuria™ affects physicians’ use of non-invasive and invasive diagnostic tests for microhematuria, gross hematuria, and bladder cancer surveillance. We conducted a survey-based study to assess physician management of nine clinical scenarios involving real-world data from patients with gross hematuria, microhematuria, and bladder cancer on surveillance. We randomly sampled 15 practicing urologists and generated data including 135 patient-by-urologist interactions and 2160 decision points. Urologists recommended a selection of diagnostic tests and procedures before and after Oncuria™ results were provided. We assessed changes in provider use of non-invasive and invasive diagnostic tests after Oncuria™ results were provided. Over 90% of all urologists changed their diagnostic behavior in at least one patient case with the addition of Oncuria™ results. The total number of diagnostic procedures was reduced by 31% following the disclosure of a negative Oncuria™ test and 27% following the disclosure of a positive Oncuria™ test. This is pilot study has the potential to shed light on the analysis of our four large multicenter international studies deploying OncuriaTM. The Oncuria™ urine-based test, a molecular diagnostic capable of ruling out the presence of bladder cancer, reduces both unnecessary invasive and non-invasive diagnostics and has the potential to reduce costs and improve patient outcomes.


2022 ◽  
Vol 21 (1) ◽  
Author(s):  
Mahlet Belachew ◽  
Mistire Wolde ◽  
Desalegn Nega ◽  
Bokretsion Gidey ◽  
Legessie Negash ◽  
...  

Abstract Background Malaria incidence has declined in Ethiopia in the past 10 years. Current malaria diagnostic tests, including light microscopy and rapid antigen-detecting diagnostic tests (RDTs) cannot reliably detect low-density infections. Studies have shown that nucleic acid amplification tests are highly sensitive and specific in detecting malaria infection. This study took place with the aim of evaluating the performance of multiplex real time PCR for the diagnosis of malaria using patient samples collected from health facilities located at malaria elimination targeted low transmission settings in Ethiopia. Methods A health facility-based, cross-sectional survey was conducted in selected malaria sentinel sites. Malaria-suspected febrile outpatients referred to laboratory for malaria testing between December 2019 and March 2020 was enrolled into this study. Sociodemographic information and capillary blood samples were collected from the study participants and tested at spot with RDTs. Additionally, five circles of dry blood spot (DBS) samples on Whatman filter paper and thick and thin smear were prepared for molecular testing and microscopic examination, respectively. Multiplex real time PCR assay was performed at Ethiopian Public Health Institute (EPHI) malaria laboratory. The performance of multiplex real time PCR assay, microscopy and RDT for the diagnosis of malaria was compared and evaluated against each other. Results Out of 271 blood samples, multiplex real time PCR identified 69 malaria cases as Plasmodium falciparum infection, 16 as Plasmodium vivax and 3 as mixed infections. Of the total samples, light microscopy detected 33 as P. falciparum, 18 as P. vivax, and RDT detected 43 as P. falciparum, 17 as P. vivax, and one mixed infection. Using light microscopy as reference test, the sensitivity and specificity of multiplex real time PCR were 100% (95% CI (93–100)) and 83.2% (95% CI (77.6–87.9)), respectively. Using multiplex real time PCR as a reference, light microscopy and RDT had sensitivity of 58% (95% CI 46.9–68.4) and 67% (95% CI 56.2–76.7); and 100% (95% CI 98–100) and 98.9% (95% CI 96–99.9), respectively. Substantial level of agreement was reported between microscopy and multiplex real time PCR results with kappa value of 0.65. Conclusions Multiplex real-time PCR had an advanced performance in parasite detection and species identification on febrile patients’ samples than did microscopy and RDT in low malaria transmission settings. It is highly sensitive malaria diagnostic method that can be used in malaria elimination programme, particularly for community based epidemiological samples. Although microscopy and RDT had reduced performance when compared to multiplex real time PCR, still had an acceptable performance in diagnosis of malaria cases on patient samples at clinical facilities.


2022 ◽  
Author(s):  
Blythe J Adamson ◽  
Robby Sikka ◽  
Anne L Wyllie ◽  
Prem K Premsrirut

The performance of Covid-19 diagnostic tests must continue to be reassessed with new variants of concern. The objective of this study was to describe the discordance in saliva SARS-CoV-2 PCR and nasal rapid antigen test results during the early infectious period. We identified a high-risk occupational case cohort of 30 individuals with daily testing during an Omicron outbreak in December 2021. Based on viral load and transmissions confirmed through epidemiological investigation, most Omicron cases were infectious for several days before being detectable by rapid antigen tests.