scholarly journals Metallic intraocular foreign body as detected by magnetic resonance imaging without complications– A case report

2017 ◽  
Vol 7 ◽  
pp. 76-79 ◽  
Author(s):  
Alexander S. Platt ◽  
Benjamin G. Wajda ◽  
April D. Ingram ◽  
Xing-Chang Wei ◽  
Anna L. Ells
2014 ◽  
Vol 7 (1) ◽  
Author(s):  
Thomas Metterlein ◽  
Frank Haubner ◽  
Birgit Knoppke ◽  
Bernhard Graf ◽  
York Zausig

2018 ◽  
Vol 46 (11) ◽  
pp. 4717-4721
Author(s):  
Baohong Wen ◽  
Jingliang Cheng ◽  
Huixia Zhang ◽  
Yong Zhang ◽  
Xiaonan Zhang ◽  
...  

Objective Intraocular foreign body (IOFB), a frequent cause of ocular trauma, causes serious damage to the eyes. This study was designed to elaborate and compare the characteristics of different magnetic resonance imaging (MRI) sequences in detecting wooden IOFBs in rabbits. Methods The right vitreous of 24 healthy rabbits was randomly implanted with diverse wooden foreign bodies (diameter φ = 0.2 mm). The T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), proton density-weighted imaging (PDWI), and susceptibility-weighted imaging (SWI) sequences were applied individually 2 weeks after the implantation. Results IOFBs were detected as linear low signals on T1WI, T2WI, PDWI, and SWI (SWI image). The detectable rates of poplar wood with a length of 0.5 mm were 0%, 50%, 0%, and 67% for T1WI, T2WI, PDWI, and SWI, respectively. SWI and T2WI sequences exhibited higher sensitivity than T1WI and PDWI. The detectable rates of the first three SWI sequences (magnitude, phase, and SWI) were all 67%, which was higher than that of the minimum intensity projection sequence (33%). Conclusion MRI is practicable in the diagnosis of wooden IOFBs. SWI and T2WI are optimal for the integrated diagnosis of wooden IOFBs and could be used for diagnosis and immediate treatment.


2014 ◽  
Vol 38 (2) ◽  
pp. 212-214 ◽  
Author(s):  
Mehmet Beyazal ◽  
Necip Pirinççi ◽  
Alpaslan Yavuz ◽  
Sercan Özkaçmaz ◽  
Gülay Bulut

2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Tomoyuki Ishida ◽  
Jun Kanamori ◽  
Hiroyuki Daiko

Abstract Background Management of postoperative chylothorax usually consists of nutritional regimens, pharmacological therapies such as octreotide, and surgical therapies such as ligation of thoracic duct, but a clear consensus is yet to be reached. Further, the variation of the thoracic duct makes chylothorax difficult to treat. This report describes a rare case of chylothorax with an aberrant thoracic duct that was successfully treated using focal pleurodesis through interventional radiology (IVR). Case presentation The patient was a 52-year-old man with chylothorax after a thoracoscopic oesophagectomy for oesophageal cancer. With conventional therapy, such as thoracostomy tube, octreotide or fibrogammin, a decrease in the amount of chyle was not achieved. Therefore, we performed lymphangiography and pleurodesis through IVR. The patient appeared to have an aberrant thoracic duct, as revealed by magnetic resonance imaging (MRI); however, after focal pleurodesis, the leak of chyle was diminished, and the patient was discharged 66 days after admission. Conclusions Chylothorax remains a difficult complication. Focal pleurodesis through IVR can be one of the options to treat chylothorax.


Sign in / Sign up

Export Citation Format

Share Document